background image

To Release from the Inverted  "Locked" Position:

Place one hand over your shoulder and hold onto the corner of the table frame.

Place your other hand on the bottom bar of the A-frame in front of you. (See Figure 9)

Pull both hands together. This will rotate the table out of the "locked" position.  Slowly move
your arms and elbows to your sides to complete the rotation.   Elbows protruding over the
sides of the table bed could get pinched between the A-frame and the table bed as you return
upright (See Figure 9A).

If your body is stretched, you will need to bend your knees to shift body weight to the
foot side of the pivot point. 

Do not lift your head or sit up while releasing form the

"locked" position.

STORING THE INVERSION TABLE

IMPORTANT NOTE:  The F9000

 will not fold for storage while in Setting “C” of the roller

hinge.  You must have the roller hinge set in either the “A” or “B” setting to do so.

• Loosen the de-rattler knob.
• Pull out the main shaft locking pin and slide the main shaft in all the way to the ankle

clamp assembly.  Allow the locking pin to engage in the storage setting.

• Rotate the table 

opposite from use

 until the table has turned 180 degrees and rests

against the cross bar on the A-frame.

• Fold the legs of the A-frame base together for compact storage. 

(See Figure 10)

Take care not to pinch your fingers.

The equipment is structurally rated at a capacity of 198 cm (6'6") or 136 kg (300 lbs).  However, please confine all inverted
activities to smooth movements.  Aggressive exercises, which involve a lot of body movement, can cause the table to tip
over resulting in serious injury or death!

WARNING - Tipover Hazard

!

Figure 10

Storage

         Owner's Manual

                          II-L201    Pg. 4

Figure 9

Figure 9A

For information about the Teeter Hang Ups

®

 5-year warranty, or if you have any problems

assembling the equipment or questions about its use, please contact Customer Service at
the appropriate location below:

* any modification to this device

will void the UL Classification

Classified as Medical

Equipment, part I in accordance

with UL 2601-1 and CAN/CSA

C22.2; General Requirements

for Safety in accordance with

Underwriters Laboratories, Inc.

U.S. and foreign patents apply.  Other foreign patents pending.

Teeter Hang Ups

®

 is a registered trademark of STL International, Inc.

and Inversion International, Ltd.
Specifications subject to change without notice.

© COPYRIGHT 2006, Inversion International, Inc.
International Law Prohibits Any Copying, 11/06

USA & Canada:

STL International, Inc.

9902 162

nd

 St. Ct. E., Puyallup, WA 98375

Toll Free (Phone) 800-847-0143  (Fax) 800-847-0188

Local (Phone) 253-840-5252  (Fax) 253-840-5757

(email)  [email protected]  (web) www.STLIntl.com

International:

Inversion International, Ltd.

PO Box: AP 59245, New Providence Island, Bahamas

(Phone)  +1-242-362-1001  (Fax)  +1-242-362-1002

(email)  [email protected]  (web) www.InversionInternational.com

European Distributor:

Teeter Ltd.

Cygnet House, Sydenham Road, Croydon, Surrey CR0 2EE, United Kingdom

(Phone) +44-(0)20-8667-0060 (Fax) +44-(0)20-8680-3999

(email)  [email protected]  (web) www.TeeterLtd.com

Authorized Representative according to MDD 93/42/EEC MDSS

MurckhardstraBe1, 30163 Hannover, Germany

It is your responsibility to familiarize yourself with the proper use of the equipment and the inherent risks of inversion, such
as falling on your head or neck, pinching, entrapment or equipment failure.

DO NOT 

use the inversion table until you have thoroughly and carefully read the Owner's Manual, viewed the Instructional

DVD, reviewed all other accompanying documents, and inspected the equipment.  

ALWAYS

 test and inspect the

equipment for smooth operation prior to each use.

WARNING

!

Содержание F9000

Страница 1: ...pins Ventral hernia Spinal injury Surgically implanted orthopedic supports Glaucoma Cerebral sclerosis Use of anticoagulants including high doses of aspirin Retinal detachment Acutely swollen joints DO NOT use if you are over 198 cm 6 6 or 136 kg 300 lbs Structural failure could occur or head neck may impact the floor during inversion DO NOT modify the equipment or use accessory attachments that a...

Страница 2: ...s or you could fall when the table inverts Figure 4 Owner s Manual II L201 Pg 2 WARNING Failure to lock the foot clamps fully could result in serious injury or death DO NOT deviate from these instructions MOUNTING AND SECURING YOUR ANKLES 1 Preparing to Mount ALWAYS wear securely tied lace up shoes with a flat sole such as a normal tennis style shoe DO NOT wear shoes with thick soles boots high to...

Страница 3: ...y balanced fulcrum It responds to very small changes in weight distribution As a result you must always test to make sure you have the correct height setting Ensure that there is clearance to rotate without contacting other objects or people Rest your head on the nylon mat and place your arms at your side Slowly place your arms on your chest ÖIf your head is lower than your feet lengthen the heigh...

Страница 4: ...ormation about the Teeter Hang Ups 5 year warranty or if you have any problems assembling the equipment or questions about its use please contact Customer Service at the appropriate location below any modification to this device will void the UL Classification Classified as Medical Equipment part I in accordance with UL 2601 1 and CAN CSA C22 2 General Requirements for Safety in accordance with Un...