HandyHeat 132 A Скачать руководство пользователя страница 3

-

Material 

One (1) PB130-230 power base

One (1) floor sensor (for floor heating modules AF & F)

One (1) wall plate (optional, in certain countries)

 

Power Base

PB130-230

Installation Instructions

Technical Specifications

Model

: PB130-230

Supply

: 230 VAC, 50 Hz

Load

: 16 A maximum (resistive only)

Power

: 3680 Watt (NI), 230 VAC

Certification

: EN60730-2-9 / EN50081-1 / EN3082-2

Storage

: -20°C to 50°C

Protection

: Class  2

Protection degree

: IP20

Automatic action

: Type 1.B

Environment

: Normally polluted 

Size (H• W •D)

: 75 x 75 x 14 mm (7.5 x 7.5 x 1.4 cm) 

NOTE: 

The terminals are designed to handle

a wire size between 0.33 to 3.1 mm2

TWO (2)

  YEAR LIMITED WARRANTY

This product is guaranteed against workmanship defects for a two-year period
following the initial date of purchase. During this period HandyHeat will repair
or replace, at our option and without charge, any defective product which has
been used under normal conditions.
The warranty does not cover delivery costs and does not apply to products
poorly installed or randomly damaged following installation. This warranty
cancels and replaces any other manufacture’s express or implied  warranty
as well as any other company commitment.

HandyHeat cannot be held liable for related or random damaged following
the installation of this product. The defective product as well as the purchase
invoice must be returned to the place of purchase or mailed, prepaid and in-
sured, to the nearest location.  

If you have any questions concerning the installa-
tion of the PB130-230 power base, contact our 
technical support team at :

Introduction

The PB 130-230 power base is designed to power a 
HandyHeat 13x series control module. The resistive 
load must not exceed 3680 watts (NI) 230 VAC (16A).

Installation Guidelines

Turn off power to the heating system at the mail power 
panel to avoid electrical shock. Installation should be 
carried out by an electrician.
All work must be conform to the most recent country’s
regulations for electrical installations and wiring.
This thermostat should be connected on a circuit equip-
ped with a fuse  or a circuit breaker. It must be installed
on a certified electrical box.
For a new installation choose a location abput 1.5 m
(5 ft.) above the floor.
The thermostat must be  installed facing the heating
system and on the inside wall.
Avoid locations where there are air drafts (top of stair-
case, air outlet), dead air spots (behind a door), direct 
sunlight or concealed chimneys or stove pipes.

Remove the screw holding the 
control module to the power 
base.
Note that the screw cannot be
completely removed.

If you have a wall plate: 

Before making the connections, make
sure that the base covers the electrical
box entirely. If not, insert the cover 
plate on  rear of the base.

NOTE: 

The cover plate can be used to cover
the plate for aesthetics.

Connect the wires:

Power

:

Terminals 1 and

  5

Load

:

Terminals 2 and

  4

Floor sensor

:

Terminals 6 and

  7

(no polarity needs
 to be respected)

 

Do not place the floor sen-
sor directly next to an ele-
ment but rather for maximum performance, the floor
sensor should be centred between the wires in the
mat (80°C max.). The temperature sensor wire can-
not lay across any heater wires.

If the load is driven through
a contractor, a snubber must
be installed at the contrac-
tor’s coil terminal. See wiring
diagram below. 

Push wires into the electrical box and
secure the base to the electrical box
anchorage. The head of the screw
must be  less than 2 mm thick. 

 

Conigure the switches ( if necessa-
ry) and istall the control module
onto the power base (refer to
the user guide).

Return power to the heating system. 

DVK-00086-001

Installation and Wiring

Lundagervej 102
DK-8722  Hedensted
Denmark

Tel. +45 7675 8030
Fax +45 7675 8032
Email: [email protected]
www.handyheat.net

Product of Denmark

Отзывы: