![HandyHeat 132 A Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/handyheat/132-a/132-a_owners-manual_3564002003.webp)
-
Material
One (1) PB130-230 power base
One (1) floor sensor (for floor heating modules AF & F)
One (1) wall plate (optional, in certain countries)
Power Base
PB130-230
Installation Instructions
Technical Specifications
Model
: PB130-230
Supply
: 230 VAC, 50 Hz
Load
: 16 A maximum (resistive only)
Power
: 3680 Watt (NI), 230 VAC
Certification
: EN60730-2-9 / EN50081-1 / EN3082-2
Storage
: -20°C to 50°C
Protection
: Class 2
Protection degree
: IP20
Automatic action
: Type 1.B
Environment
: Normally polluted
Size (H• W •D)
: 75 x 75 x 14 mm (7.5 x 7.5 x 1.4 cm)
NOTE:
The terminals are designed to handle
a wire size between 0.33 to 3.1 mm2
TWO (2)
YEAR LIMITED WARRANTY
This product is guaranteed against workmanship defects for a two-year period
following the initial date of purchase. During this period HandyHeat will repair
or replace, at our option and without charge, any defective product which has
been used under normal conditions.
The warranty does not cover delivery costs and does not apply to products
poorly installed or randomly damaged following installation. This warranty
cancels and replaces any other manufacture’s express or implied warranty
as well as any other company commitment.
HandyHeat cannot be held liable for related or random damaged following
the installation of this product. The defective product as well as the purchase
invoice must be returned to the place of purchase or mailed, prepaid and in-
sured, to the nearest location.
If you have any questions concerning the installa-
tion of the PB130-230 power base, contact our
technical support team at :
Introduction
The PB 130-230 power base is designed to power a
HandyHeat 13x series control module. The resistive
load must not exceed 3680 watts (NI) 230 VAC (16A).
Installation Guidelines
Turn off power to the heating system at the mail power
panel to avoid electrical shock. Installation should be
carried out by an electrician.
All work must be conform to the most recent country’s
regulations for electrical installations and wiring.
This thermostat should be connected on a circuit equip-
ped with a fuse or a circuit breaker. It must be installed
on a certified electrical box.
For a new installation choose a location abput 1.5 m
(5 ft.) above the floor.
The thermostat must be installed facing the heating
system and on the inside wall.
Avoid locations where there are air drafts (top of stair-
case, air outlet), dead air spots (behind a door), direct
sunlight or concealed chimneys or stove pipes.
Remove the screw holding the
control module to the power
base.
Note that the screw cannot be
completely removed.
If you have a wall plate:
Before making the connections, make
sure that the base covers the electrical
box entirely. If not, insert the cover
plate on rear of the base.
NOTE:
The cover plate can be used to cover
the plate for aesthetics.
Connect the wires:
•
Power
:
Terminals 1 and
5
•
Load
:
Terminals 2 and
4
•
Floor sensor
:
Terminals 6 and
7
(no polarity needs
to be respected)
Do not place the floor sen-
sor directly next to an ele-
ment but rather for maximum performance, the floor
sensor should be centred between the wires in the
mat (80°C max.). The temperature sensor wire can-
not lay across any heater wires.
If the load is driven through
a contractor, a snubber must
be installed at the contrac-
tor’s coil terminal. See wiring
diagram below.
Push wires into the electrical box and
secure the base to the electrical box
anchorage. The head of the screw
must be less than 2 mm thick.
Conigure the switches ( if necessa-
ry) and istall the control module
onto the power base (refer to
the user guide).
Return power to the heating system.
DVK-00086-001
Installation and Wiring
Lundagervej 102
DK-8722 Hedensted
Denmark
Tel. +45 7675 8030
Fax +45 7675 8032
Email: [email protected]