DAY/HOUR/MIN - Set the day and clock setting.
PGM - Program the schedule (programs).
MODE - Select the operating mode.
RETURN - To  exit a function.

To configurate temperature setpoints: 

program when Automatic mode is enabled.

Current operating mode (auto     / manual     ). In
Auto mode , the program’s associated setpoint is
also displayed (         ).

 Comfort

  

Economy and

Vacation.

Adjust the floor temperature (AF only).

—Increase and decrease temperature.

—Indicates the number of the current

Indicates the room or floor temperature.

Heating indicators ( see “Temperature Control”
below). 

HandyHeat 132-A

This model has been designed to control a room’s ambi-
ent temperature. 
The HandyHeat 132-A has one temperature sensor loca-
ted in the control module.

HandyHeat 132-AF

This model is designed  to use a floor sensor to control 
the room temperature. 
The HandyHeat 132-AF has two temperature sensors:
- The first one, installed in the control module, controls 
  the ambient temperature.
- The second one, installed in the floor (and connected
  to the power base), limits the temperature of the floor 
  (the default setting of this limit is 28°C).

HandyHeat 132-F

This model is designed to control floor heating systems.
The HandyHeat 132-F has a temperture sensor installed 
in the floor (sensor is connected to the power base).
 

HandyHeat 132 has two switches, located on the 
upper-left part on the rear of the control module, 
which are used to set the following options:

Early Start
When the Early Start function is enabled disabled
by default), HandyHeat 132 calculates the optimum
system start time to obtain the desired temperature 
by the set time.  To enable function:

                    Position  switch  #1  down.

Note: When this function is enabled, 
the system can be activated before 
the program’s start time.

Temperature Display
By default, HandyHeat displays the temperature in  °C. 
If you wish to change  to  °F.

                          Position  switch  #2  down.

Note: When you switch from °C to °F or vice
versa, the       and      setpoints must be
redefined.

Control Module

HandyHeat132 A/F/AF

Owner’s Guide

Thank you for choosing HandyHeat 132, a programmable
thermostat, that provides both energy savings and total
comfort.

HandyHeat 132 Description

Model Overview

Configure the Switches

Align the bracket tabs on the control module with the
holes located on top of the power base.
This control module must be installed on a PB130 
series power base.

Note: Keep the thermostat’s air vents clean and free
from obstructions.

Note: The screw cannot be removed completely.  

On the first installation , the screen displays:
0:00, MO,     and temperature (room/floor).

For Floor Heating Installations:

One of the two following messenges  may be 
displayed when a problem occurs:

LO: The floor temperature is below 0°C, 
       the temperature sensor is defective, or not
       connected.
       The heating indicator       is displayed and
       the relay is closed ( energized ).

HI:  The floor temperature is above 60°C,
       or the temperature sensor is defective. 

       Set the time (HOUR - MIN).
        
       Set the day (DAY).

If you remove the module from its base for more than
2 hours, the time and day will have to be reprogrammed.   

Comfort       and Economy    Setpoints.

These setpoints are associated with the schedule’s pro-
grams (programs 1 &3 = Comfort, programs 2 & 4 = Eco-
nomy) and are preprogrammed as follows:

          A & AF mode is -     20°C,     18°C
          F mode is -    28°C,      20°C

To modify a setpoint:
          Set the temperature using        and press and hold
          the        or     button until it is displayed on the 
          screen. Press MODE/RETURN to exit.

Vacation Setpoint

The vacation setpoint is associated to the Vacation opera-
ting mode and is preprogrammed to 10°C. To modify this 
setpoint, repeat above step.

Floor Temperature Setpoint (AF mode only)

The floor temperature limit is preprogrammed to 28°C to
avoid damage to your floor.
To modify, press the adjustment button (below   ) using a
pointed object, set the desired temperature using       and
press MODE/RETURN to exit.

 

    HandyHeat 132 offers three operating modes:

Automatic        - Executes the schedule.
    
      Press MODE to select       . The current prog-
      ram number is displayed.
      You can temporarily pass the current  prog-
      ram by setting a specific temperature setpoint using 
            or by selecting one of the pre-defined setpoint
      buttons           . The new setpoint will be maintained
      until the beginning  of the next program.

Manual       - Maintains constant temperature. 

      Press MODE to select      .
      Set temperature      or selsct one of the pre-
      defined setpoint buttons (       ).

Vacation       - Maintains the Vacation setpoint
during a prolonged absence.

      Press       .

(

)

Install the Control Module

Power base

Control module

Air vents

Air vents

First Power ON

Set the Time and Day

Adjust the Temperature Setpoints 

Select the Operating Mode

DVK-00079-001

 