4
3.2 Plasma Torch & Earth Clamp Connections
Install the HST68 plasma torch
by first removing the plastic cap on the brass machine plug. Insert the
plug into the female socket on the front panel and screw locking collar in place to secure torch.
Install the earth clamp
cable by inserting the brass plug into the female socket on the front panel being
certain to align the tab with the channel and “TWIST-LOCK” into place to secure.
3.3 Input Power Connections
Supply input connection of PCA68 as show to the right.
208-240VAC LINE CONNECTION:
Machine is provided with NEMA 6-50P LINE Service cord to be
plugged into any 6-50R outlet with 208-240VAC, single-phase power and
50-amp circuit breaker.
In the event LINE power supply is over voltage (>245) or under voltage (<195), protection circuit inside
the machine will illuminate alarm light and current will be cut off.
If the power supply voltage continually goes beyond the safe work voltage range, it will shorten the life
of the machine. If this occurs, the below measures should be taken:
Change the LINE power supply. Such as, connect the welder to a dedicated circuit.
Shut off other machines using LINE power supply at the same time as welding.
WARNING: Any modification or removal of factory service power cord will VOID WARRANTY!
3.4 Input Gas Connections
The PCA68 PFC plasma cutter is supplied with a compressed air filter/dryer and adjustable air flow
knob. The air hose from the compressor should be connected directly to this air regulator
.
Connecting
additional regulator on line can reduce air flow to the cutting torch and damage the system.
The pressure regulator should be set
~70 psi (4.8 bar)
and flow rate should be 210 SCFH (100 lpm)
minimum with ¼” (6mm) minimum hose diameter at 1/4G regulator input.
WARNING: Maximum Line air pressure should not exceed 125 PSI (8.6 bar)