H&S AUTOSHOT HSP60 Скачать руководство пользователя страница 8

 

 

 

 

4.2 Cutting Preparation 

1

Connect the power cable to electrical outlet (the input voltage, refer to the section 3). 

2

Connect the air hose to the air supply equipment and set pressure to ~70 psi (4.2 bar).   

3

Connect the earth cable to the workpiece not being removed with cut. 

4

Make certain operator is wearing proper safety glasses (1.7-6.0 DIN) gloves and protective clothing. 

5

Make certain work area is clean and free of all hazordous liquids & gases. 

6

Turn ON the power switch and check the power pilot lamp is illuminated. 

7

Flip RUN/SET switch to SET position for 10 seconds to purge any moisture from the torch cable. 

8

Flip RUN/SET switch to RUN and machine is ready to cut. 

4.3 Cutting Operation 

 

 

Notes:  (1) In the event of alarm lamp ON when cutting, release torch trigger and allow unit to cool until 

the alarm resets and lamp goes OFF, then press on the switch to start cutting again. 

(2) In the automatic air purge mode (SET), pressing trigger will not ignite arc. 

(3) In the event less than 30 psi air pressure is supplied to the machine, pressing trigger will 

not ignite arc. 

(4) After extended usage, nozzle and electrode should be changed to insure optimum cutting 

performance. 

(5) The alarm lamp will illuminate when shield cup is removed from torch head and torch will 

not arc. Shiled cap must be re-installed securely in place and lamp will turn off. 

 

Turn ON 

the power 

source 

Release 

torch 

trigger to 

stop arc 

Tip finishes 

cut on the 

work-piece, 

the cutting 

arc changes 

into pilot arc 

again 

Place 

cutting tip 

on edge of 

surface 

 

Press 

trigger to 

ignite the 

pilot arc 

Post-gas 

cooling for 
10 seconds 

 

Slide tip to 

work-piece, 

changing the 
pilot arc into 

cutting arc 

Arc 

extinguished 

Содержание HSP60

Страница 1: ...Read this Owner s Manual Completely before attempting to use this equipment Save this manual and keep it handy for quick reference Pay particular attention to the safety instructions we have provided...

Страница 2: ...NECTIONS 3 3 3 INPUT POWER CONNECTIONS 4 3 4 INPUT GAS CONNECTIONS 4 4 OPERATION 5 4 1 LAYOUT FOR THE FRONT REAR PANEL 5 4 2 CUTTING PREPARATION 6 4 3CUTTING OPERATION 6 5 MAINTENANCE 7 5 1 CUTTING TO...

Страница 3: ...and gases from the plasma arc depend on the kind of metal being used coatings on the metal and the different processes You must be very careful when cutting or cutting any metals which may contain on...

Страница 4: ...en gas can be eliminated or dissipated Trapped hydrogen gas that is ignited will cause an explosion NOISE Noise can cause permanent hearing loss Plasma arc processes can cause noise levels to exceed s...

Страница 5: ...on class H Net weight kg 22 9 Cooling method AF Note The above parameters are subject to change with the improvement of machines 3 Installation 3 1 Unpacking Identify and account for each item per the...

Страница 6: ...illuminate alarm light and current will be cut off If the power supply voltage continually goes beyond the safe work voltage range it will shorten the life of the machine If this occurs the below meas...

Страница 7: ...s insufficient air pressure Below 50 Psi 5 Ready DC Indicator Indicator is ON when DC output is active trigger is depressed 6 RUN SET Power ON in RUN Change to SET for 10 sec air purge Change to RUN t...

Страница 8: ...when cutting release torch trigger and allow unit to cool until the alarm resets and lamp goes OFF then press on the switch to start cutting again 2 In the automatic air purge mode SET pressing trigge...

Страница 9: ...swirl ring by lifting off electrode and place both on bench 4 Locate electrode wrench and remove electrode by rotating counter clockwise RH thread 5 Inspect torch head for clogged air ports or damage...

Страница 10: ...ff the power source install the electrode or nozzle and screw shield cup down properly then turn on the power source D The cutting torch fail to ignite the arc when torch trigger depressed DC pilot li...

Страница 11: ...hnician repair L Torch cuts but low quality 1 Current A control set too low increase current setting 2 Torch is being moved too fast across work piece reduce cutting speed 3 Excessive oil or moisture...

Страница 12: ...10 5 4 Electrical principle drawing...

Страница 13: ...10 H S AUTOSHOT SERVICE 888 677 3798...