Setting the operating temperatures of the unit 

 
 

 

Unit must be switched on 

 

 

 Press Set key once  

 

Press set key twice 

 

 

Adjust  

¿

 and 

À

 key 

 

Adjust  

¿

 and 

À

 key 

 

93 

 

86 

 
 

Controller error codes 

 

Code Reasons 

Remedies 

E2 

Corrupted 

memory 

data 

• 

There is a memory 
corruption within the 
configuration data of 
the instrument 

• 

Switch off the power. 

• 

Reconnect the power supply - if code still 
displayed replace the controller unit. 

E0 

Cabinet 

probe 
alarm 

• 

Probe type incorrect 

• 

Probe fault 

• 

Fit correct probe type 

• 

Check probe connections  

E1 

Evaporator 

probe 
alarm 

• 

Probe type incorrect 

• 

Probe fault 

• 

The evaporator 
temperature is 
outside the limits of 
the controller 

• 

Fit correct probe type 

• 

Check probe connections 

• 

Test the temperature close to the probe to 
ensure its between the set operating range 

 

Replacement parts

 

 

Part

 

Part number

 

Quantity 

Per unit 

Lid handle 

BLO18707-2 

Lid handle fixing screw 

BLO18707-3 

On/off switch 

E01035 

10 Amp fuse 

E01510 

Fuse holder 

E01505 

Controller E012342 

Probe E01406 

Transformer E04160 

Mains plug 

E10040 

Mains cable 

E06124 

3M 

Heater element 

E01235 

Lamp neon 

E01008 

Relay mini 30amp 

E04041 

Timer E04045 

Ball valve 

T60029 

 

 
 

Issue 1:2 06.05.03 

10

Содержание PRET 601774

Страница 1: ...User Manual Soup cooker 601774 H K EUROPE...

Страница 2: ...details 4 Warranty 5 Purchase record 5 Installation 6 Operation 6 Cleaning 8 Trouble shooting 8 Controller configuration 9 Setting the operational temperature 10 Controller error codes 10 Replacement...

Страница 3: ...Alteration of the controller may result in operating difficulties Disconnect power source before maintaining or repairing the unit Do not immerse the unit into water Allow the cooker to cool down pri...

Страница 4: ...ty 12 litres Manufacturer s details H K Equipment Ltd 1 Cosford Lane Swift Valley Rugby CV21 1QN United Kingdom Tel 44 0 1788 554000 Fax 44 0 1788 554100 H K Manufacturing Ltd Cherry Orchard Industria...

Страница 5: ...r of a part s non compliance H K Ltd does not accept responsibility for defects caused by the mishandling abuse or neglect of equipment Parts replaced after the one year period has elapsed are covered...

Страница 6: ...se 50 Hz single phase 13Amp Temperature settings on the controller have been factory pre set and should not require adjustment Operation Once the unit has been positioned 1 Ensure the water drain valv...

Страница 7: ...d for 20 minutes to allow the soup to be cooked The red heat neon indicates this operation The controller s will then adjust the temperature to 85 C so that the soup can be held at the point of servic...

Страница 8: ...also be cleaned daily with a damp cloth using a mild soap and water mixture Trouble shooting Problem Cause Repair Unit will not work 1 Unit not plugged in 2 No power to unit Controller display not ill...

Страница 9: ...eously hold 0 Set previous setting 2 3 key 0 Set previous setting 11 4 key 1 Set previous setting 2 5 key 2 Set previous setting 3 4 key 5 Set previous setting 1 5 key 6 Set previous setting 20 6 key...

Страница 10: ...robe connections E1 Evaporator probe alarm Probe type incorrect Probe fault The evaporator temperature is outside the limits of the controller Fit correct probe type Check probe connections Test the t...

Страница 11: ...Wiring schematic Issue 1 2 06 05 03 11...

Отзывы: