background image

1

     push and hold the toggle in the direction of travel desired until you reach the landing  
     or hallway.

9.

  Check for damage. Before use check the lift for external damage. Report unusual 

     noises, such as squeaking and creaking, to your supplier. To avoid accidents repairs
     and preventive maintenance should only be carried out by engineers qualified to do so. 

10.

The stairlift must not be used in the event of a fire or as a means of escape during a fire.

11.

If the stairlift is not fitted with a communication device, we recommend that you always

     have one to hand.

12. 

Only leave the stairlift at the designated points at the top and bottom of the rail.

Structure

The strength and the suitability in general of wall, staircases, terraces, upper floors, 
banisters, plinths etc. which are to support or surround the installation have been 
verified and ensured by the customer, who therefore accepts all relative responsibilities. 
Neither Handicare nor its authorised dealers may be held responsible for the suitability 
of the structures which surround and support the installation. 

MAINTENANCE
Cleaning

Clean the stairlift regularly with a damp cloth; avoid excessive use of water. Ensure the 
track is kept free of dirt and dust. Over time the track wheels may leave a mark on the 
rail. 

Preventive maintenance

In addition to cleaning your stairlift, periodic preventive maintenance is necessary for 
continued long-term use.
Your stairlift must be serviced at least once a year by a qualified person. If your stairlift 
has more than two users we recommend a minimum of two services per year.
Please make an electrical socket available to provide local lighting if required during 
inspection and servicing. Lighting to a minimum value of 50 lux shall be provided at the
boarding points whilst the stairlift is in use. Most light bulb packaging will detail the lux
value of the light bulb. 

GUARANTEE AND LIABILITY

The manufacturer guarantees that this stairlift (excluding batteries) will be repaired free
of charge should manufacturing and/or material defects occur within 12 months of the
purchase date, during normal use in accordance with the recommended user, 
installation and maintenance instructions. Damage caused by normal wear and tear, 
overloading or misuse and the replacement of batteries in the remote control is not 
covered by this guarantee.
We recommend that your stairlift is serviced annually by an appropriately qualified 
stairlift engineer.
Under no circumstances can the manufacturer accept responsibility for death, personal
injury, damage to property, or incidental, unforeseen consequences and/or costs or 
damage resulting from the use of your stairlift.

USER 

MANUAL

   13

Содержание Xclusive

Страница 1: ...U S E R M A N U A L EN...

Страница 2: ......

Страница 3: ...IMPORTANT INFORMATION FAULT FINDING ATTACHMENTS A Reminders B Emergency operation C Diagnostic codes D Spareparts Thank you for choosing a Handicare stairlift This manual is for the XCLUSIVE lift type...

Страница 4: ...The XCLUSIVE lift can be upgraded with the Automatic Swivel seat Powered Footrest and the Continuous Charge kit options to create even more seat comfort and user friendliness 1 Diagnostic Display 2 Jo...

Страница 5: ...position The diagnosic display will be illuminated when switched on Fold down the footplate the armrests and seat page 10 OPTIONAL POWERED FOOTREST PLACE FEET Place your feet on the footplate Ensure...

Страница 6: ...t clicks into the holder Put the key in the switch and turn it ninety degrees clockwise Check that the chair is in the locked position RIDE Move the joystick in the desired direction of travel The dis...

Страница 7: ...press the emergency stop again SWIVEL The lift stops automatically at the end of the rail You should now swivel the seat manually making it easier to get on and off To do this push down the lever A Sw...

Страница 8: ...LOOSEN BELT Unfasten the seat belt STAND UP Stand up from the seat 6 USER MANUAL...

Страница 9: ...under the seat downwards B Swivel the seat until you hear a click The seat is now in the locked position PARK Press and hold the button on the remote control until the lift reaches a charge point Upon...

Страница 10: ...e top and bottom of the rail there may be additional charge points If the lift is not in the correct position at the charge point the lift beeps for 15 seconds and the display shows a 2 The lift does...

Страница 11: ...AT option lets you swivel the seat automatically to face the direction you are going to walk in To do this push and hold the joystick in the direction of travel AUTOSWIVEL POWERED FOOTREST CONTINUOUS...

Страница 12: ...er the armrest The stairlift should beep whilst folding the footrest Always ensure the footplate is in the down position during travel CONTINUOUS CHARGE KIT When the CONTINUOUS CHARGE strip is install...

Страница 13: ...USER MANUAL 11...

Страница 14: ...bserve appropriate safety regulations regarding risk of electric shock and physical injury 1 Provide an unobstructed environment by ensuring that the entire track is free of obstacles 2 Take environme...

Страница 15: ...wheels may leave a mark on the rail Preventive maintenance In addition to cleaning your stairlift periodic preventive maintenance is necessary for continued long term use Your stairlift must be servic...

Страница 16: ...d in this manual is based on general specifications regarding the construction material properties and working methods known to us at the time of publication alterations and improvements are therefore...

Страница 17: ...Refer to APPENDIX C for an explanation of the diagnostic codes Please inform the customer service operator of this code when reporting any fault DIAGNOSTIC DISPLAY CHAIRPOSITION EMERGENCY STOP ARMREST...

Страница 18: ...the seat using the handle located to the left or right under the seat until it clicks into position EMERGENCY STOP Problem the lift does not travel in either direction the display shows a 0 1 and the...

Страница 19: ...folded down Solution fold down the armrest fully KEY Problem the lift does not travel in either direction and the display shows a 0 Cause the key operated switch is in the off position Solution turn t...

Страница 20: ...te control are flat Solution replace the batteries in the remote control C A U S E S O L U T I O N C A U S E S O L U T I O N POWER Problem the lift batteries are not recharging the lift beeps for 15 s...

Страница 21: ...splay Cause The lift may be switched off Solution Turn the lift on Problem the lift travels in one direction only and the display shows a 4 6 Cause there is an obstacle between the lift and the stairs...

Страница 22: ...ove the key from the switch whenever you leave the lift B Never remove the lift plug from the wall socket REMINDERS REMINDERS EMERGENCY OPERATION DIAGNOSTIC CODES SPAREPARTS page 20 page 21 page 23 pa...

Страница 23: ...further the hand winder can be used to move the lift to a charging point B 2 Turn off the lift B 3 Open the cover in the front plate of the chassis by pressing the tab at the top of the cover A Take...

Страница 24: ...B 5 A B 5 Turn the hand winder as indicated on the winder access point Then wind the lift in the required direction B 6 Replace the cap B 7 Replace the winder A and the cover B B 8 Turn on the lift 2...

Страница 25: ...LT Action Display No display Charging but the lift does not drive Final limit circuit activated Final limit circuit activated Final limit circuit activated Requires charge Off charge Top track limit...

Страница 26: ...Action Display F A U LT Action Display F A U LT Action Display F A U LT Low battery voltage Joystick activated Joystick activated IR address fail The main power relay not open The main power not clos...

Страница 27: ...fault during charging Power supply fault during charging Power supply fault when battery on float Main board hardware fault Over current Sleeping mode Sleeping mode If the display is showing anything...

Страница 28: ...S60001 S P A R E P A R T S S W I V E L P O W E R K I T FSF60001 S P A R E P A R T S S W I V E L P O W E R K I T XPK40008 FSR30055 7m 5m FSR30053 FSR30054 2x FSR30057 FSR30057 10x FSR30054 14x FSR30053...

Страница 29: ...D60002 S P A R E P A R T S S W I V E L P O W E R K I T FSD60004 S P A R E P A R T S S W I V E L P O W E R K I T FSD60003 S P A R E P A R T S S W I V E L P O W E R K I T FSS60001 S P A R E P A R T S S...

Страница 30: ...R E P A R T S S W I V E L P O W E R K I T FSD60011 S P A R E P A R T S S W I V E L P O W E R K I T XPK42002 172001 52650 XPK42003 000172 52000 5x 5x XPK43005 XPK43001 XPK42005 XPK42001 XPK42006 4x 2x...

Страница 31: ...60013 S P A R E P A R T S S W I V E L P O W E R K I T FSS30100 RNA55006 XPK43003 4 XPK44001 XPK42002 XSK40001 FSS60002 S P A R E P A R T S S W I V E L P O W E R K I T 000933 0028 FSS20007 4x XHK40001...

Страница 32: ...Handicare GmbH Hausberger Stra e 16 32457 Porta Westfalica Deutschland Tel 49 0 571 973398 55 Fax 49 0 571 973398 56 data handicare com USER MANUAL 000411 1507 rev C 000411 1507...

Отзывы: