background image

 

12

6. 

Display 

 
On the lift is a display which shows a diagnostic code to help you  locate the cause of 
the breakdown. The codes can be found in the user- and installation manual. See 
also chapter 15. 

7. 

The toggle 

 
The lift is operated by the toggle on the armrest. The toggle or the button for the 
powered footrest raiser can be swapped from right to left on side. 
The lift will not ride when the armrests are in the folded position. It does however 
operate on the remotes. During the ride the diagnostic display show “8” or “9”. 
 
 
 
 
 
 
 
 
 
 
An installation toggle loom can be used to ride the power pack without chair. 
In case of a public building when the key switch should switch off the toggle but the 
remotes should stay operational, the key switch needs to be transferred from the 
safety line to the control line. 

8. 

The remotes 

 
 
 
 
 
 
 
 
 
 
 
The remotes function on infrared and they need to be fixed to the walls adjacent to 
the stairlift.  On the backside is a dipswitch for setting a different code. 
The lower button is a special button for parking the lift. On the backside is a red or 
green cover. Green means the remote functions on radiofrequency (2,4 Ghz),  red 
means the remote functions on infrared. 
Under this cover you can find a dipswitch to set a different canal. 
The infrared remotes work out of the box. If they don’t, they can be linked as follows: 
Press and hold the red button on the board P1. A yellow light will illuminate on the 
board. Press any button on the handset and the light will go out. 

Содержание Xclusive

Страница 1: ......

Страница 2: ...1...

Страница 3: ...3 2 Display codes 4 3 References 6 4 Glossary 7 5 Testing 11 6 Display 12 7 Toggle 12 8 Remotes 12 9 Safety edges 13 10 The batteries 14 11 The battery charger 15 12 Board 16 13 Options 17 14 Rescuing...

Страница 4: ...ld be tested where the components are located and how they react to certain situations The subsequent chapters deal with repairing faults Flow charts are used in some cases where step by step choices...

Страница 5: ...y edge activated 30 7 Low battery voltage 31 8 UP travel direction 21 9 DOWN travel direction 21 A B Toggle switch active at power up 21 C IR address fail 32 d Relay not open 20 E Relay not closed 20...

Страница 6: ...activated 30 7 Low battery voltage 31 8 UP travel direction 21 9 DOWN travel direction 21 A b Toggle switch active at power up 21 C IR address fail 32 d Relay not open 20 E Relay not closed 20 F Brake...

Страница 7: ...it switch 22 278 The batteries 24 31 The charger 31 The tractionmotor 21 The brake 21 The display 24 The on off switch 24 The toggle 23 26 The armrestswitches 23 26 The remotes 32 The infrared receive...

Страница 8: ...sary Unit 1 30 amp fuse 2 5 amp fuse 3 Batteries 4 Motor 5 Main board 6 S8 S9 Overspeed governor switch 7 S2 S3 Limit switch 8 S4 S6 Power pack edge switch 9 S5 S7 power pack edge switch 2 1 4 5 6 6 3...

Страница 9: ...ard powered footrest 2 Board powered swivel 3 S10 front chassis top bottom edge switch 4 S11 front chassis top bottom edge switch 5 Powered footrest motor 6 Powered swivel motor 7 Display 8 S1 Main sw...

Страница 10: ...9 Footrest 1 Footrest switch S12 2 Footrest switch S13 1 2...

Страница 11: ...10 Chair S14 Toggle S15 Control powered footrest 1 S17 Emergency switch 2 S20 Manual overrun autoswivel 3 S18 Keyswitch 4 S21 S22 Hall sensors 5 S19 Seat swivel switch 1 2 3 4 4 5...

Страница 12: ...tage test mode Remove the correct connector from the board Push the measuring pins into the back of the connector see photo Check that you are testing between the correct connector pins numbers No bee...

Страница 13: ...y switch should switch off the toggle but the remotes should stay operational the key switch needs to be transferred from the safety line to the control line 8 The remotes The remotes function on infr...

Страница 14: ...itches for the power pack Detection switches for the front chassis The handing of the safety edges is when sitting on the lift The general safety edges The general safety edge prevents the lift from m...

Страница 15: ...ge of one of the batteries is at least 5V less than that of the other it can be assumed the battery is faulty If the voltage between the batteries varies there is something wrong with them Guarantee N...

Страница 16: ...een as code 1 takes priority Code r This code will occur when the lift is charging If the power supply is disconnected while the lift is charging the r code will display A fault with the 33V power sup...

Страница 17: ...16 12 Boards 125 Mainboard 126 Powered swivel 126 Powered footrest...

Страница 18: ...tage through the communication loom to the 126 pcb The 126 pcb then reduces the output to the correct voltage for the attached motor to power the option Depending on which option is attached voltage w...

Страница 19: ...ith the user on the lift when a safety measure is switched off If it is not possible to remove the fault without danger to the user first release the user In such case ensure that your are positioned...

Отзывы:

Похожие инструкции для Xclusive