Assembly

Unpacking and inspection

The following is included in the EvaDrive package:

•        Handlebar
•        EvaDrive unit
•        Allen key
•        2 bracket for handlebar

The following is included in the EvaDrive battery package:

•        Battery (Replaces the battery of Eva mobile lift)
•        Charger
•        Charger cable 

 
Check to ensure that no components are left in the packaging. 
Inspect the drive unit for signs of damage.

Periodic inspection must be performed at least once yearly. Use only original spare parts. Service and maintenance must 
be performed according to instructions in the manual.

The drive unit must be charged for at least 10 hours before it is used for the first time.
Install the drive unit on the lift according to the accompanying assembly instructions. (Separate document) Assembly 
must be performed by Handicare authorized personnel.

33.4 inch/  
850 mm

Installation of the handlebar

The handlebar must be installed on the mast at a height of at least 33.4 inch 
from the floor. Measure from the lowest point of the handlebar.

The handlebar is secured using the accompanying Allen key.

The complete Eva lift package with EvaDrive includes the following:

•        Handlebar
•        2 bracket for handlebar

Intended use of the product

EvaDrive in an add-on system to Handicare Eva Mobile lifts in order to provide a power assisted drive function to the rear 
wheels. The EvaDrive system can either be delivered as an accessory to be retro-fitted to Eva450EE or Eva600EE, or as 
a complete unit with the drive system fitted from the factory. The EvaDrive shall be used in the following situations and 
environments:

• 

 

In a passive patient lift situation with a user in the lift, reducing the effort from the caregiver when  

 

maneuvering the lift.

• 

 

In a dry environment and on a level surface.

• 

 

Home Care environments.

• 

 

Healthcare environments.  

5

I N S T R U C T I O N S   F O R   U S E

System

RoMedic

TM

English

Содержание SystemRoMedic EvaDrive

Страница 1: ...oMedic TM Instructions for use English Bruksanvisning Svenska Brukermanual Norsk Brugsvejledning Dansk K ytt ohje Suomi Gebrauchsanweisung Deutsch Handleiding Nederlands Manuel utilisateur Fran ais Ma...

Страница 2: ...driving function in all directions Check that the accessory EvaDrive is properly mounted on the lift Always read the user manuals for all assistive devices used during a transfer Keep the user manual...

Страница 3: ...0 mm Installation of the handlebar The handlebar must be installed on the mast at a height of at least 33 4 inch from the floor Measure from the lowest point of the handlebar The handlebar is secured...

Страница 4: ...press the down button and run the boom all the way down Test base width adjustment Activate the system press the button for base width adjustment open the undercarriage to maximum width and then pres...

Страница 5: ...tions are made by authorized personnel Never attempt to lift the mobile lift unit by the handlebar Ensure that there are no obstacles or people in the way of the lift Never stand on the lift during op...

Страница 6: ...unction is described in the respective section in the user manual or in the user manual for the respective accessory Below is a brief description of the functions that are available for caregivers and...

Страница 7: ...level Solid light indicates battery capacity remaining Blinking light indicates error A service technician can determine the source of the error Power button Press lightly to activate EvaDrive Wait ab...

Страница 8: ...eration of the lift is not possible until EvaDrive has completed automatic calibration If the handlebar is hit violently or subjected to impact the sensors neutral values can be affected so much that...

Страница 9: ...top blinking All or parts of the battery scale blink quickly Something is wrong with the lift s electrical system Restart EvaDrive If there is still a problem contact Handicare Red light battery scale...

Страница 10: ...ned see Fig 2 The yellow LED light on the control panel indicates that the wheels are in the turned position Grasp the handlebar and hold in the safety switch then turn the lift in the desired directi...

Страница 11: ...rive cover Emergency stop switches off all of the lift s electrical functions The battery scale continues to light continuously Resetting Turn the emergency stop button in the direction of the arrows...

Страница 12: ...ge the aluminium and the plastic materials If disinfection is needed 70 ethanol 45 isopropanol or similar should be used Disinfect the parts that come in contact with a user before the lift is used fo...

Страница 13: ...ght Eva450Drive 127 87 lbs 58 kg Eva600Drive 141 1 lbs 64 kg Weight heaviest part Eva450Drive 97 lbs 44 kg Eva600Drive 110 2 lbs 50 kg Turning diameter Eva450Drive 54 inch 1340 mm Eva600Drive 61 8 inc...

Страница 14: ...All measurement are in mm inch Tolerance 5 mm 0 2 When the handle is placed 1000 mm from floor Eva450Drive 25 0 9 427 16 8 1307 51 4 1450 57 1 240 9 4 900 1100 35 4 43 3 124 I N S T R U C T I O N S F...

Страница 15: ...n mm inch Tolerance 5 mm 0 2 Eva600Drive When the handle is placed 1000 mm from floor 806 31 7 395 15 5 25 0 9 432 17 1408 55 4 1566 61 6 240 9 4 900 1100 35 4 43 3 125 I N S T R U C T I O N S F O R U...

Страница 16: ...es RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment RF emissions CISPR 11 Class A The EvaDri...

Страница 17: ...e 2 kV for common mode Mains power quality should be that of a typical commercial or hospital environment Voltage dips short interruptions and voltage variations on power supply input lines IEC 61000...

Страница 18: ...occur in the vicinity of equipment marked with the following symbol NOTE 1 At 80MHz and 800MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnet...

Страница 19: ...ncy of transmitter m 150 kHz to 80 MHz P d 2 1 80 MHz to 800 MHz P d 2 1 800 MHz to 2 5 GHz P d 3 2 0 01 0 12 0 12 0 24 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 For transmitters ra...

Страница 20: ...oMedic offers improvement of both work environment and quality of care and at the same time achieves significant cost savings Always make sure that you have the correct version of the manual The most...

Отзывы: