REVISION HISTORY
REV.
DESCRIPTION
DATE
APPROVED
B
C
D
1
2
A
3
2
1
4
B
A
5
6
C
3
SCALE:1:5
DWG. NO.
REV.
NAME
DATE
DRAWN
APPROVED BY
SHEET 1 OF 1
WEIGHT:
COMMENTS:
STATUS:
TITLE
MATERIAL:
SIZE
139402makn@z40
g
2014-09-26
A4
Unless otherwise stated,
general tolerances
according to ISO 2768-m
This drawing and any information or descriptive matter set out hereon are the confidential and copyright property of Handicare
and must not be disclosed, loaned, copied or used for manufacturing, tendering or any other purpose without their written permission.
Final inspection
Inspect the lift for signs of wear and damage. Check all castors and castor brakes.
Check all connections and fixtures including screws and bolts. Check the packaging to
ensure that there are no loose parts.
Check the emergency stop function by activating the emergency stop button, and
then pressing either the up or down button. If nothing happens when the up or down
buttons are pressed, the emergency stop is functioning properly.
Grasp the hand control, press the up button and run the lift arm all the way up. Then,
press the down button and run the liftarm all the way down.
Test base-width adjustment function by pushing down on the respective pedals for
widening and narrowing the base. For EE use the buttons on the hand control.
Test lift function by lifting a person (not a user) using an approved sling. At the same
time, check the emergency lowering function with someone in the lift, see section on
Emergency lowering.
If the lift is functioning correctly, connect the charger and check to ensure that the
charging lamp on the control box lights up.
NOTE!
Before the lift is used for the first time, it must be charged for at least 4 hours. See
section on Charging batteries.
Keep the user manual where it is accessible to users of the product.
EE
EM
No burrs allowed
Break sharp edges: Rmax:0.3 mm / 0.3 mmx 45degrees
Replaces drawing/part number (Linido Part No)
Unless otherwise stated, general tolerances according to ISO 2768-m
Omitted dimensions according to
[90003465_06_Carina350EM.dwg/step]
REVISION HISTORY
REV.
POS.
DESCRIPTION
DATE
DRAWN BY
Art. no.
extension
RAL code
Color
00
Stainless steel polished
Blanc
02
RAL 9010
White
03
RAL9005
Black
04
RAL3003
Red
07
RAL5002
Blue
08
RAL9001
Créme white
09 (special)
Divers
Color
D
E
F
C
1
2
3
4
B
A
3
2
1
5
C
D
4
6
7
8
A
B
This drawing and any information or descriptive matter set out hereon are the confidential and copyright property of Handicare
and must not be disclosed, loaned, copied or used for manufacturing, tendering or any other purpose without their written permission.
06
SCALE
PROJECTION
Material <not specified>
MATERIAL SPECIFICATION:
A3
2015-03-05
32312.24 g
90003465
Carina350EM
Released
SIZE
MATERIAL:
TITLE
STATUS
WEIGHT:
SHEET 1 OF 1
CREATED
DATE
NAME
REV.
DWG. NO.
1:20
5
6
E
hc-laek
6
M A N U A L System
RoMedic
TM
Содержание SystemRoMedic Carina350EM
Страница 2: ......
Страница 18: ...Serial number 117 M A N U A L SystemRoMedic TM...