Fortress 1700 DT/TA
52
Possible cause
Action
Action to
be taken
by
•
There is a loose connector.
•
Correct the connection if
possible, otherwise contact
your dealer.
Yourself
+
Dealer
•
The battery voltage is too low
•
Check the battery voltage.
See ‘Battery condition
meter’.
•
Charge the batteries for 8
hours.
•
Check operation of the
battery charger.
Yourself
•
The scooter drives too slowly
•
Turn the speed control
knob to the right
Yourself
•
Overheated motor
•
Remove the jack key from
the receptacle and allow
the scooter to cool down.
Yourself
Sometimes simply switching the scooter off and back on again will correct the
problem.
If you cannot solve the problem by using the list above, contact your dealer.
7.2
Automatic circuit breaker
The scooter has been equipped with an automatic
circuit breaker (A), located on the rear cover under
the seat
In normal circumstances, the automatic circuit
breaker will not pop out and the scooter will be ready
for use.
When the electric circuit is overloaded or shorted, the
automatic circuit breaker will switch off the electric
system to prevent damage.
Overload can be caused if the motor is overheated. If the automatic circuit
breaker switches off the electric circuit of the scooter, it will pop out.
By pressing the automatic circuit breaker button back in again, you can try to
restart the scooter. If the automatic circuit breaker button pops out again, wait
15 to 20 minutes to allow the motor to cool off, and then try resetting again.
A