Programming the Scanner
3-38
[Data Verifier]
Scan “Program” to enter the programming mode.
Scan “Verifier Control” and set bar code symbology to
“
08
” (Interleaved 2 of 5).
Scan “Identified Data Length” and set the length to “
16
.”
Scan “1st Identified Character” and set the identified position to
“
00
,” then set the identified character to “
39
” (Hex value for 9).
[Data Formatter]
Scan “Formatter Control” and set bar code symbology to “
08
.”
Scan “1st Insertion” and set the identified position to “
06
,” then
inserted characters to “
09
” (Hex value for TAB), “
53
” (Hex value
for S), “
4E
” (Hex value for N).
Scan “2nd Insertion” and set the identified position to “
12
,” then
inserted character to “
09
.” Finally, you must scan the “
FIN
”
(Finish) code to terminate this selection.
Scan “3rd Insertion” and set the identified position to “
16
,” then
inserted character to “
09
.” Finally, you must scan the “
FIN
”
(Finish) code to terminate this selection.
[Data Replacer]
Scan “Replacer Control” and set bar code symbology to “
08
.”
Scan “1st Replacement” and set the identified position to “
00
,”
then replaced character to “
41
” (Hex value for A).
At this point the data string is as follows:
A81025[TAB]SN123456[TAB]9876[TAB]. We still need to delete
the 98 from the string to get the desired output.
[Data Organizer]
Scan “Organizer Control” and set bar code symbology to “
08
.”
Scan “1st Organization” and set the identified position to “
16
,”
then set the data transmission to “
0
” (before).
The character position, which counts the added “SN” and TABs,
is identified as 00, 01, 02,… so the 16
th
character is “
9
.” The
include/exclude control, which will be set to 0 for exclude in the
last step of the instructions below, determines that the “
9
” in the
16
th
position will not be sent. All of the characters before the 16
th
position will be transmitted.
Scan “2nd Organization” and set the identified position to “
17
,”
which is “
8
,” in this case, then set the data transmission to “
1
”
to transmit all of the characters after position 17. Whether
position 17 gets transmitted along with the string is determined
by the include/exclude control, which, in this case, will be
excluded in the next step.
[Include/Exclude Control]
Scan “Include/Exclude Control”.
Scan “
0
” for transmitted data excluding the data of the identified
position.
Scan “
END
” (Exit) to terminate the programming.