background image

5

Keyboard Country

Scan the 

Program Keyboard Country

 bar code 

below, then scan the numeric bar code(s) from 
page 11, then the 

Save

 bar code to program the 

keyboard for your country.  As a general rule, the 
following characters are not supported by the 
imager for countries other than the United States:
@  |  $  #  {  }  [  ]  =  /  ‘  \  <  >  ~.

Note: For complete list of country codes, see the 

User’s Guide for this product at our website,  

www.handheld.com.

Country Code

Scan

Country Code

Scan

Belgium

1

Italy

5

Denmark

8

Norway

9

Finland

2

Spain

10

France

3

Switzerland

6

Germany/Austria

4

USA (Default)

0

Great Britain

7

Program Keyboard Country 

Save

Содержание IMAGETEAM 4620

Страница 1: ...4620 5620 Quick Start ...

Страница 2: ... the base then power up the computer once the base is fully connected When the base is connected and powered up put the imager in the base to establish a link The green LED on the base flashes to indicate the imager s battery is charging USB Connection ...

Страница 3: ...2 Keyboard Wedge Connection Serial RS 232 Connection ...

Страница 4: ...he code and larger when it is farther from the code Hold the imager close to smaller bar codes and farther away from large bar codes to get a proper read If the bar code is highly reflective e g laminated you may need to tilt the imager at an angle so the bar code can be scanned Note If the imager beeps 3 times when scanning a bar code the link has not been established If the imager beeps once the...

Страница 5: ...4 PC Interface Scan the bar code that describes the PC or interface you are using AT PS2 Keyboard Wedge Default RS 232 USB Keyboard PC Emulate External Keyboard Japan DOS V ...

Страница 6: ...e following characters are not supported by the imager for countries other than the United States Note For complete list of country codes see the User s Guide for this product at our website www handheld com Country Code Scan Country Code Scan Belgium 1 Italy 5 Denmark 8 Norway 9 Finland 2 Spain 10 France 3 Switzerland 6 Germany Austria 4 USA Default 0 Great Britain 7 Program Keyboard Country Save...

Страница 7: ... imager is unlinked Override Locked Imager If you need to replace a broken or lost imager that is linked to a base scan the Override Locked Imager bar code with a new imager and place that imager in the base The locked link will be overridden the broken or lost imager s link with the base will be removed and the new imager will be linked Open Link Override Locked Imager ...

Страница 8: ... unlinked it will no longer communicate with the base Scan the Unlink Imager bar code to unlink an imager Trigger The following bar codes will allow you to use the reader in Manual Trigger mode need to press the trigger to read or Presentation mode the reader is activated when it sees a bar code Unlinking Imager Manual Trigger Default Presentation Mode ...

Страница 9: ...ts against accidental rereads of the same bar code Suffix If you want a carriage return after the bar code scan the Add CR Suffix bar code To add a tab after the bar code scan the Add Tab Suffix bar code Otherwise scan the Remove Suffix bar code to remove the suffixes Medium Reread Delay Add CR Suffix Remove Suffix Add Tab Suffix ...

Страница 10: ...selection is enabled and function codes are contained within the scanned data the imager transmits the function code to the terminal Charts of these function codes are provided in your User s Guide When the imager is in keyboard wedge mode the scan code is converted to a key code before it is transmitted Add Code ID Prefix to all Symbologies Enable Default Disable ...

Страница 11: ...ebsite www handheld com 1 Scan the Enter Data Format symbol 2 Primary Alternate Format scan 0 for Primary Format 3 Terminal Type scan 99 for any terminal type 4 Code I D scan 99 for any bar code type 5 Length scan 9999 for any length bar code 6 Editor commands use the Programming Chart that follows 7 Scan Save to save your entries Enter Data Format Clear All Data Formats Save ...

Страница 12: ...11 Programming Chart 0 2 1 4 3 5 6 7 ...

Страница 13: ...12 A B C D E F 9 8 Save ...

Страница 14: ...istance If you need assistance installing or troubleshooting your imager please call your Distributor or the nearest Hand Held Products technical support office North America Canada Telephone 800 782 4263 option 4 8 a m to 6 p m EST Fax number 315 685 4960 E mail natechsupport handheld com Europe Middle East and Africa Telephone European Ofc Int 31 0 40 79 99 393 U K Ofc Int 44 1925 240055 E mail ...

Страница 15: ...ion To download the full User s Guide for these products visit our website at www handheld com Product Service and Repair Hand Held Products provides service for all its products through service centers throughout the world To obtain warranty or non warranty service return the unit to Hand Held Products postage paid with a copy of the dated purchase record attached Contact the appropriate location...

Страница 16: ... Fax 239 263 9689 E mail laservice handheld com Brazil Hand Held Products Brazil Telephone 55 21 2176 0250 Fax 55 21 2176 0249 E mail suporte handheld com Europe Middle East and Africa Hand Held Products Europe Telephone 31 0 40 29 01 633 Fax 31 0 40 2901631 E mail euservice handheld com Asia Pacific Hand Held Products Asia Pacific Telephone 852 2511 3050 Fax 852 2511 3557 E mail apservice handhel...

Страница 17: ...hipment This warranty does not cover any Hand Held Products product which is i improperly installed or used ii damaged by accident or negligence including failure to follow the proper maintenance service and cleaning schedule or iii damaged as a result of A modification or alteration by the purchaser or other party B excessive voltage or current supplied to or drawn from the interface connections ...

Страница 18: ...option will either repair or replace the product without charge except for return shipping to Hand Held Products EXCEPT AS MAY BE OTHERWISE PROVIDED BY APPLICABLE LAW THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER COVENANTS OR WARRANTIES EITHER EXPRESSED OR IMPLIED ORAL OR WRITTEN INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE HAND HELD P...

Страница 19: ...mited duration of the warranty for the IT2020 5B the 4620 and the 5620 is for three 3 years The limited duration of the warranty for the imager battery is for one 1 year Disclaimer Hand Held Products Inc Hand Held Products reserves the right to make changes in specifications and other information contained in this document without prior notice and the reader should in all cases consult Hand Held P...

Страница 20: ...Hand Held Products Inc 700 Visions Drive P O Box 208 Skaneateles Falls NY 13153 0208 Crdlss QS Rev A 2 06 ...