10 - 4
Example #4: What are the device’s settings for all Codabar selections?
Enter:
cbr?.
Response:
CBRENA1[ACK],
SSX0[ACK],
CK20[ACK],
CCT1[ACK],
MIN2[ACK],
MAX60[ACK],
DFT[ACK].
This response indicates that the device’s Codabar Coding Enable (CBRENA) is
set to 1, or on;
the Start/Stop Character (SSX) is set to 0, or Don’t Transmit;
the Check Character (CK2) is set to 0, or Not Required;
concatenation (CCT) is set to 1, or Enabled;
the Minimum Message Length (MIN) is set to 2 characters;
the Maximum Message Length (MAX) is set to 60 characters;
and the Default setting (DFT) has no value.
Trigger Commands
You can activate and deactivate the scanner with serial trigger commands.
First, the scanner must be put in Manual/Serial Trigger Mode either by scanning
the Manual/Serial Trigger Mode bar code (
). Once the scanner is in serial trigger
mode, the trigger is activated and deactivated by sending the following com-
mands:
Activate:SYN T CR
Deactivate:SYN U CR
The scanner scans until a bar code has been read, until the deactivate com-
mand is sent, or until the serial time-out has been reached (see
on page 3-4 for a description, and the serial command on
Содержание 3820
Страница 1: ...2020 3820 Cordless System User s Guide...
Страница 7: ...Required Safety Labels 3820SR0C0BE 3820...
Страница 62: ...2 18 2020 3820 User s Guide...
Страница 86: ...5 6 2020 3820 User s Guide...
Страница 132: ...8 4 2020 3820 User s Guide...
Страница 162: ...11 8 2020 3820 User s Guide...
Страница 175: ......
Страница 176: ......
Страница 180: ...Hand Held Products Inc 700 Visions Drive P O Box 208 Skaneateles Falls NY 13153 0208 3820 UG Rev A 5 06...