background image

 

Hamworthy Heating Limited                                 Purewell Variheat                                                        500001168/B 

PUREWELL VariHeat (c & he Models) 

INSTRUCTIONS FOR USE 

Note

:- This boiler is for use on Natural Gas (2nd Family) 

I

2H

 only. Only a competent person must carry 

out any adjustments. 

WARNING

:  All installations MUST conform to the relevant Gas Safety and Building Regulations.  

It is law that all gas appliances are installed and maintained by competent persons in accordance with 
the above regulations.  

This appliance must only be used for the purpose and under the conditions, for which it is designed. This 
appliance  is  not  intended  for  use  by  persons  (including  children)  with  reduced  physical,  sensory  or 
mental  capabilities,  or  lack  of experience  and  knowledge,  unless  they have  been  given  supervision  or 
instructions concerning use of the appliance by a person responsible for their safety. Children should be 
supervised to ensure that they do not play with the appliance.  

LIGHTING INSTRUCTIONS 

 

Carry out the following procedure for each  boiler.

 

1) 

Ensure  the  electrical  mains  supply  to  the  boiler 
module  is  switched  on  and  that  any  external 
controls  are  calling  for  heat  (Time  clock,  BMS 
etc.).

 

2) 

Use  the  Mode  Button  (3)  to  select  the  desired 
operating mode. 

 

3) 

The  boiler  should  go  through  it’s  sequence  and 
finish at the default screen shown above.

 

4) 

By using the Info button (10) the boiler status can 
be  viewed.  To  return  to  the  default  screen  press  
Mode button (3).

 

5) 

To  change  the  clock  time  (24hrs)  press  ‘Prog’ 
button (6) or (7). Set the clock to the desired time 
by pressing the value button (8) or (9). Having set 
the time press the Mode button (3) followed by the  
Info button (10).

 

6) 

To  set/change  the  program  timings,  press  ‘Prog’ 
button  (6)  or  (7).  To  select  the  desired  switching 
times  press  the  ‘Prog’  button  (6)  or  (7)  scrolling 

The boiler display screen provides various levels of access to view and change the performance parameters of 
the boiler.  
A  code is used to access the various security levels of the program.  
The User can change parameters relating to time clock, boiler program timings and boiler temperature setpoint. 
 
In addition, the User can view performance data and reset specific lockouts. Should a lockout occur, a code will 
flash alternatively with the time of day, indicating the fault.  

 
Should a fault code appear which cannot be reset, or a fault code repeatedly occurs, contact Hamworthy 
Heating for assistance. Do not continue to operate or use the boiler as this may cause damage to the con-
trols.

 

Button   

Function 

 

Reset Lockouts 

 

Not Used 

 

Selection of Operating Mode 

Automatic (time control) 

Continuous ‘ Normal’ temperature 

Continuous ‘ Reduced ‘ setback temperature 

Standby - boiler off. 

 

Adjustment of boiler or room temperature 

 

Not used 

6, 7 

 

Selection of operating parameter 

8, 9 

 

Adjustment of parameter value 

10 

 

Select Information display screens 

 

1) Boiler off - based on ‘On/Off’ button  

10 