IMPORTANT:
It is essential to use the 235594 SG70-120 LPG Conversion Kit
supplied as an option by HAMWORTHY. Refer to the kit instructions
for installing specific components and before modifying the LMS
settings, adjusting the gas valve, and adjusting the regulator.
IMPORTANT:
ONLY
on 70 to 120kW storage tanks
AA031262 - DR-SG 70-538, AA031263 - DR-SG 80-538, AA031264 - DR-
SG 100-538, AA031265 - DR-SG 120-538
Models
Gas
9504
9512
9524
9529
20-210
G20
5450
5840
2200
6030
G31
5450
5700
2100
5700
25-210
G20
5450
5840
2200
7390
G31
5450
5700
2100
6970
30-210
G20
5450
5840
2200
8500
G31
5450
5700
2100
7850
35-356
G20
5000
3870
2250
6250
G31
5000
3800
2200
5630
50-356
G20
5000
3870
2250
8890
G31
5000
3800
2200
7880
60-356
G20
5000
3870
2250
9800
G31
5000
3800
2200
8800
70-538
G20
3200
3300
1700
3810
G31
3200
3470
1620
3470
80-538
G20
3200
3300
1700
4330
G31
3200
3470
1620
3740
100-538
G20
3200
3300
1700
5270
G31
3200
3470
1620
4600
120-538
G20
3200
3300
1700
6400
G31
3200
3470
1620
5700
4.8.1.3.
Changing the ignition, pre-ventilation, minimum and maximum speeds
Put the Dorchester DR-SG on standby.
IMPORTANT:
Always replace seals after disassembly.
IMPERATIVELY check the different seals after assembly.
If necessary, press the ESC button to return to the main screen.
Open the Settings / Safety unit menu at specialist level.
Adjust the pre-ventilation speed (9504),
ignition speed (9512), minimum
speed (9524) and maximum speed (9529) settings:
Page 34 / 104
00U07337760-A
DORCHESTER DR-SG -
Installation, Operation and Maintenance