background image

ELEKTRA 2000                                                                                                                                    Hamtronix

 

7

 

BASIC OPERATION 

 

CONTROLLING YOU REPEATER REMOTELY 

 
With exception of audio levels, all functions are controlled remotely with your radio DTMF keypad.  
 

COMMAND SINTAXES 

 
Commands are as following: 
 

PPPPFF0# 

 

Where:  

PPPP

 

 

4 digits password 

FF

  

 

2 digits function 

O

  

 

1 digit option 

#

  

 

Enter 

 
See the command for change the sound of courtesy tone: 

 

1234066# 

 
Your  controller  will  answer  valid  commands  with  two  high  frequency  confirmation  beeps  (function  08 
must  be  enabled).  If  the  entered  command  is  invalid,  a  long,  low  frequency  tone  will  be  heard.  The 
command  must  be  entered  completely  in  one  transmission.  If  you  release  PTT  switch  before  you 
complete a command, the entered numbers will be discarded.  
 
You  can  enter  more  than  one  command  without  having  to  release  PTT  between  them.  #  acts  like  a 
command separator. If entering a command and you made a mistake, just press * to clear the entered 
string and start over. 
 

Note 1:

 DTMF commands without a correct password will not generate an error message. They will just 

be discarded. 

 

Note 2: 

Some commands don’t require an option or may require extra procedures. These exceptions will 

be explained in details at function description. 

 

Note  3: 

Default  password  is  1234.  After  get  acquainted  with  the  controller  commands,  change  this 

password.

 

 

 

WARNING 

 

To get a correct decoding of DTMF tones, the signal must be free of noises or jamming. If the 

repeater is busy, wait until it becomes free prior to sending commands.

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание Elektra 2000

Страница 1: ...Hamtronix Repeater Controller Elektra 2000 Instruction Manual Software V2 10 Hardware Revision H...

Страница 2: ...07 Roller Beep 09 08 Confirmation Tone 09 09 Time out Action 09 10 ID Test 09 11 Repeater CTCSS Enable 09 11 Link CTCSS Enable 09 14 ID Timer 09 15 ID Selection 10 16 CW ID Frequency 10 17 CW Speed 10...

Страница 3: ...for one 1 year from the date of purchase This Warranty do not covers damage deterioration or failure resulting from 1 Accident misuse abuse neglect unauthorized product modification or failure to foll...

Страница 4: ...00 mA Active in low CN2 LINK Pin Signal Description 1 RX RX audio from link transceiver 2 GND Ground 3 MIC TX audio to link transceiver 4 PTT PTT signal output to link transceiver 5 COR COR COS signal...

Страница 5: ...receiver has positive COR jumper J2 should be at 1 2 position NEGATIVE COR If you receiver has negative COR jumper J2 should be at 2 3 position Note COR for link port works the same way using at jump...

Страница 6: ...e Ideally the level of a coming signal should be retransmitted with the same level Ask for someone to transmit a tone or a DTMF tone turn off mute function for this approach at repeater input frequenc...

Страница 7: ...1 23 Link Port 0 OFF 1 Aux 2 Ctrl 3 Link and 4 Cross 11 24 Transmission Test 0 OFF 1 Carrier and 2 Carried with Tone 11 25 Simplex Repeater 0 OFF 1 ON 2 ON beep 12 26 Repeater Time out 0 9 X 30s 12 27...

Страница 8: ...PTT switch before you complete a command the entered numbers will be discarded You can enter more than one command without having to release PTT between them acts like a command separator If entering...

Страница 9: ...This time must be less than the sum of hang time and courtesy tone duration or the courtesy tone will be missed 04 DURATION OF COURTESY TONE Default 1 Determine the duration of courtesy tone 0 No Cour...

Страница 10: ...e a correct CTCSS to operate the repeater port 0 Disable 1 Enable Note This function should only be activated if a CTCSS decoder optional is installed and its logic output is connected to CN1 6 The lo...

Страница 11: ...Hz 6 900 Hz 9 1200 Hz C 1500 Hz 1 400 Hz 4 700 Hz 7 1000 Hz A 1300 Hz D 1600 Hz 2 500 Hz 5 800 Hz 8 1100 Hz B 1400 Hz 17 CW ID SPEED Default 4 Determine the speed for CW ID 1 Slowest 2 Slow 3 Medium 4...

Страница 12: ...ed and stay in alarm until a command is sent to turn it off A siren sound will be transmitted over the air 0 Disable 1 Enable Note Even with alarm activated the repeater will still be available for co...

Страница 13: ...er in order to gain control 27 32 REMOTE OUTPUTS 1 6 Default 0 6 remote outputs are available for general purpose use 0 Disable 1 Enable 2 Pulse inverts state for 100 ms Example To enable output 5 pre...

Страница 14: ...VOICE MESSAGE DURATION Default 1 1 One 20s message 2 Two 10s messages 41 VOICE ID PRIORITY Default 0 When repeater is busy and the ID time is up or the voice is playing back and a signal is received t...

Страница 15: ...ET Function 37 but can be done even without the programmed password or MASTER RESET password Remove J1 to power off Press and hold button S1 Place J1 to power on When green led RX become light release...

Страница 16: ...Serial Number Software Version V2 10 Master Reset Hamtronix 55 19 3601 8540 www hamtronix com 2013...

Отзывы: