background image

Screws

Lock ring

Bulbs

Light kit 
assembly

Glass shade

Glass holder

Wire connection 
plugs 

N O T E

:   B e f o r e   s t a r t i n g   i n s t a l l a t i o n ,  

disconnect the power by turning off the circuit 
breaker or removing the fuse at fuse box.

Turning power off using the fan switch is 
not sufficient to prevent electric shock.

1. Attach the light kit to the switch housing by 

feeding the light kit wires (black and white) 
through the hole of switch housing and then 
screw it onto the switch housing by nut & 
lock washer.  Be sure it is tight enough to 
prevent light kit from vibrating loose. (Fig. 
16)

2. Locate two single white and blue wires in 

the switch housing labeled  FOR LIGHT. 

3.  Make the polarized plug connections:
       - White to white  
       - Blue to black

4. 

5. Carefully push all wires back into the 

switch housing, then install the light kit 
assembly onto the mounting plate with 4 
screws provided. Be sure to tighten all 
screws. (Fig. 17) 

While holding the light kit assembly under 

your fan, snap together the wire connection 
plugs .

6. Remove the lock ring from the socket by 

turning the lock ring counter-clockwise 
Until it unlocks.  Insert the glass into the 
glass holder and turn the lock ring 
clockwise to tighten the glass.  Repeat 
for the remaining glass.  (Fig. 17)

7. With the power off, insert the light bulbs 

(included) into the light kit sockets.  Max. 
60 watts.

8. Restore power and your light kit is ready 

for operation.

Figure 17

Switch housing

Light kit

Nut

Lock washer

Figure 16

 

Installing the Light Kit 

9. 

NOTE:

 Light bulbs have no warranty, 

can be purchased at local light bulb 
specialty store or from our service center.

Содержание Torrington

Страница 1: ...eeling Brass finishes of this type give their longest useful life when protected from varying weather conditions A certain amount of wobble is normal and should not be considered a defect Servicing pe...

Страница 2: ...Safety Rules Unpacking Your Fan Installing Your Fan Installing the Light Kit Your Care of Your Fan Troubleshooting Specifications Operating Transmitter 1 2 3 9 10 11 12 13 Table of Contents...

Страница 3: ...connections spliced conductors should be turned upward and pushed carefully up into the outlet box The wires should be spread apart with the grounded conductor and the equipment grounding conductor o...

Страница 4: ...10 Light kit 11 Glass shades 12 6 13 14 16 Balancing kit 4 0 Watt medium base bulbs 4 Receiver with 6wire nuts Transmitter holder 2 mounting screws 2 plastic plugs 15 Extra plasticplug 1 2 3 6 4 5 8 9...

Страница 5: ...support must be able to fully support the moving weight of the fan at least 50 lbs Do not use plastic outlet boxes Figures 1 2 and 3 are examples of different ways to mount the outlet box Note You may...

Страница 6: ...with the holes in the collar on top of the motor housing Fig 7 Carefully insert the hanger pinthrough the holesin the collar a half turn ecorative ring WARNING FAILURE TO PROPERLY INSTALL LOCKING PIN...

Страница 7: ...igure 8 Step 1 Figure 9 Insert the receiver into the mounting bracket with the flat side of the receiver facing the ceiling Step 2 Figure 10 Motor to Receiver Electrical Connections Connect the black...

Страница 8: ...canopy up to ceiling and over the 2 screws on the hanger bracket Rotate canopy clockwise Next while holding the canopy with one hand slide the canopy cover over the screws and rotate clockwise until t...

Страница 9: ...bleis still noticeable 4 If the blade wobble is still noticeable interchanging two adjacent side by side blades can redistribute the weight and possibly result insmoother operation Rubber washer Blade...

Страница 10: ...g Plate Step 1 Remove 1 of the 3 screws from the mounting ring and loosen the other 2 screws Do not remove Step 2 Place the key holes on the mounting plate over the 2 screws previously loosened from t...

Страница 11: ...te to white Blue to black 4 5 Carefully push all wires back into the switch housing then install the light kit assembly onto the mounting plate with 4 screws provided Be sure to tighten all screws Fig...

Страница 12: ...ng area as shown in Figure 21 This allows you to set your heating unit on a lower setting without affecting your comfort Restore power to the ceiling fan and test for proper operation 1 HI MED LOW but...

Страница 13: ...sh The plating is sealed with a lacquer to minimize discoloration or tarnishing Do not use water when cleaning This could damage the motor or the wood or possibly causean electrical shock 3 You can ap...

Страница 14: ...3 Make surewire nut connectionsare not rubbingagainst each otheror the interiorwall of theswitch housing CAUTION Make suremain power isoff 4 Allowa 24 hour breaking in period Most noiseassociated with...

Страница 15: ...W C F 52 120 3 04 Xx kgs Xx kgs Xxx Xx Xx Xxxx 120 120 Fan Size Speed Volts Amps Watts Low Medium High 13 Specifications Distributed by Your Other Warehouse LLC 12100 Little Cayman Dr Baton Rouge LA...

Отзывы: