HAMPTON BAY Spoleto II Spoleto II Скачать руководство пользователя страница 4

Safety Rules - Read and Save These Instructions

1

To reduce the risk of electric shock, insure electricity has been turned off 
at the circuit breaker or fuse box before beginning.

All wiring must be in accordance with the National Electrical Code 
“ANSI/NFPA 70-1999” and local electrical codes.  Electrical installation 
should be performed by a qualified licensed electrician.

WARNING:

 To reduce the risk of electrical shock or fire, do not use this 

fan with any solid-state fan speed control device.  It will permanently 
damage the electronic circuitry.

CAUTION: 

To reduce the risk of personal injury, use only the screws 

provided with the outlet box.

The outlet box and support structure must be securely mounted and 
capable of reliably supporting a minimum of 35 pounds. Use only UL 
Listed outlet boxes marked 

“FOR FAN SUPPORT”

.

The fan must be mounted with a minimum of 7 feet clearance from the 
trailing edge of the blades to the floor.

Avoid placing objects in path of the blades.

To avoid personal injury or damage to the fan and other items, be 
cautious when working around or cleaning the fan.

Do not use water or detergents when cleaning the fan or fan blades.  A dry 
dust cloth or lightly dampened cloth will be suitable for most cleaning.

After making electrical connections, spliced conductors should be turned 
upward and pushed carefully up into outlet box.  The wires should be 
spread apart with the grounded conductor and the equipment-grounding 
conductor on one side of the outlet box and ungrounded conductor on the 
other side of the outlet box.

All set screws must be checked and retightened where necessary before 
installation.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

WARNING

TO REDUCE THE RISK OF PERSONALL INJURY, DO NOT BEND THE 
BLADE ARMS (ALSO REFERRED TO AS FLANGES), WHEN INSTALLING 
THE BRACKETS, BALANCING THE BLADES OR CLEANING THE FAN.  DO 
NOT INSERT FOREIGN OBJECTS IN – BETWEEN ROTATING FAN 
BLADES.

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL 
INJURY, MOUNT FAN TO OUTLET BOX MARKED ACCEPTABLE FOR 
FAN SUPPORT WITH THE SCREWS PROVIDED WITH THE OUTLET BOX.

Содержание Spoleto II Spoleto II

Страница 1: ...Spoleto II 52 in Ceiling Fan Owner s Manual Spoleto II Ventilador de Techo de 1 32 m Manual del Propietario 326 201...

Страница 2: ...Spoleto II by Hampton Bay...

Страница 3: ...has been manufactured with the highest standards of safety and quality Table of Contents Safety Rules 1 Unpacking Your Fan 2 Installing Your Fan 3 Operating Your Fan 10 Care of Your Fan 11 Troubleshoo...

Страница 4: ...oid placing objects in path of the blades To avoid personal injury or damage to the fan and other items be cautious when working around or cleaning the fan Do not use water or detergents when cleaning...

Страница 5: ...or assembly 1 2 3 4 5 Motor housing Decorative cover 4 speed wall control with 2 mounting screws and 3 wire nuts Mounting plate with 2 mounting screws 6 7 8a 8b WARNING DO NOT INSTALL OR USE FAN IF AN...

Страница 6: ...SCREWS PROVIDED WITH THE OULET BOX OUTLET BOX COMMONLY USED FOR THE SUPPORT OF LIGHTING FIXTURE MAY NOT BE ACCEPTABLE FOR FAN SUPPORT AND MAY NEED TO BE REPLACED CONSULT A QUALIFIED ELECTRICIAN IF IN...

Страница 7: ...otate the fan until the next blade is positioned for measurement Repeat for each blade Measurements deviation should be within 1 8 Run the fan for 10 Minutes Use the enclosed Blade Balancing Kit if th...

Страница 8: ...nrod is available at any Home Depot store Route wires exiting from the top of the fan motor through the coupling cover canopy cover canopy and then through the ball downrod Figure 8 1 2 3 4 WARNING FA...

Страница 9: ...d with your outlet box Figure 9 Security tighten the two mounting screws Carefully lift the fan assembly up to the ceiling mounting bracket and seat the hanger ball in the mounting bracket socket Make...

Страница 10: ...upply source White wire from fan to white wire from the A C supply source Connect the fan ground wire green to the household ground wire If your outlet box has a ground wire green or bare copper conne...

Страница 11: ...and place the key hole on the canopy over the screw on the mounting bracket turn canopy until it locks in place at the narrow section of the key holes Fig 14 Align the circular hole on canopy with th...

Страница 12: ...usly loosened from the mounting ring turn motor housing until it locks in place at the narrow section of the key holes Secure by tightening the 2 screws previously loosened and the one previously remo...

Страница 13: ...er on a higher setting without affecting your comfort Cool weather Clockwise direction An upward airflow moves warm air off the ceiling area Fig 19 This allows you to set your heating unit on a lower...

Страница 14: ...4 Here are some suggestions to help you maintain your fan Check main and branch circuit fuses or breakers Check line wire connections to the fan and switch wire connections in the switch housing Chec...

Страница 15: ...W C F 52 120 7 06 kgs 15 53 lbs 8 06 kgs 17 73 lbs 2 07 Low Medium Medium High High 0 17 0 28 0 36 0 50 6 92 17 55 29 79 59 96 50 87 111 157 1353 8 2320 79 3345 58 4811 32 These are approximate measu...

Страница 16: ...unauthorized persons shall render the warranty invalid There is no other express warranty Hampton Bay hereby disclaims any and all warranties including but not limited to Those of merchantability and...

Отзывы: