HAMPTON BAY S7-AFL04112 Скачать руководство пользователя страница 8

8

Natural Gas Conversion


Disconnect the gas hose from the gas valve (B).
Disconnect the gas tube (F) from the orifice elbow (G). 
Remove the two M4 nuts and remove the orifice holder (I).

NOTE: 

Natural gas conversion must be performed only 

by your natural gas provider or service company.

NOTE: 

NEVER USE A FLAME TO CHECK FOR LEAKS.

Stick the conversion label on the rating plate as shown below.

Replace the propane orifice (J) with the natural gas orifice 
(AA) from the kit and reinstall the orifice bracket (I) by 
tightening the nuts as shown in below diagram. Reconnect 
and tighten the gas tube (F) to the orifice (AA). Apply a 
solution of soapy water to all connections to check for 
leaks. If soap bubbles continue to form, the connection has 
a leak. If a leak is found, close the tank valve and tighten all 
connections.

Metal Rating Plate

Serial Number _________________

Model Number: 98300

CAUTION: The gas pressure regulator provided with this appliance must be used. This regulator is set for an outlet pressure of 

Minimum clearance from combustible constructions: Sides: 24 in.609 mm. Top 72 in. 1828 mm.
FOR OUTDOOR USE ONLY. If stored indoors, detach and leave cylinder outdoors.

This appliance has been converted to use Natural Gas. Input 30,000 Btu/hr.

Max Gas Supply Pressure 7 in w.c. (1.74 kPa) Min. Gas Supply Pressure 5 in w.c. (1.24 kPa)

Conversion Label

      WARNING: Improper installation, adjustment alteration, service or maintenance can cause injury or

property damage. Refer to the owner’s information manual provided with this appliance. For assistance,

or additional information, consult a qualified installer, service agency, or the gas supplier.

Содержание S7-AFL04112

Страница 1: ...t needs Thank you for choosing Hampton Bay USE AND CARE GUIDE CAROL STREAM 7PC HIGH DINING SET FIREPIT Questions problems missing parts Before returning to the store call Hampton Bay Customer Service...

Страница 2: ...should be carefully supervised when they are anywhere near the appliance the appliance or placed on or near the appliance Any screen or guard removed for servicing an appliance must be replaced prior...

Страница 3: ...well ventilated area out of the reach of children Disconnected cylinders must have threaded valve plugs tightly installed and must not be stored in a building garage or any other enclosed areas 2 41 2...

Страница 4: ...iated with shipments outside continental North America at any time or for any reason WARRANTY EXCLUSIONS This warranty is subjected to the exclusions set forth above In addition the following are excl...

Страница 5: ...ce SPECIFICATIONS Input 30 000 BTU hr 20 000 BTU hr Low fire Propane Regulator Pressure 11 in water column 7 in water column Natural Gas Minimum Inlet Pressure Clearances to Combustible Surfaces Sides...

Страница 6: ...trode F Gas tube H Ignition module FP0003 1 1 1 1 1 1 1 FP1329 FP0310 FP0311 FP1298 G Orifice elbow FP0006 HW0705 1 1 1 1 FP1078 2 FP0585 1 FC0553 FP1419 FP1420 FP1421 1 FP1299 I J K L M N O P Q Orifi...

Страница 7: ...ck wise to tighten Turn the handle counterclock wise to remove The hose must point down Open the control door and check that the valve is turned all the way clockwise to the OFF position NOTE Holes do...

Страница 8: ...connection has a leak If a leak is found close the tank valve and tighten all connections Metal Rating Plate Serial Number _________________ Model Number 98300 CAUTION The gas pressure regulator prov...

Страница 9: ...continue to hold the control knob in for 10 to 15 seconds Release the control knob The control knob should pop back again 3 4 position and turn off the tank valve 1 5V AAA BATTERY COMARTMENT INSTALL...

Страница 10: ...the wire is connected to the ignition module Check that the electrode is not cracked or broken The burner does not stay lit after lighting Check that the tip of the thermocouple is even with the top o...

Страница 11: ...problems missing parts Before returning to the store call Hampton Bay Customer Service 8 a m 7 p m EST Monday Friday 9 a m 6 p m EST Saturday 1 855 HD HAMPTON HAMPTONBAY COM Retain this manual for fu...

Отзывы: