background image

2

Table of Contents ........................................................... 2
Safety Information .......................................................... 2
Product Specifications ................................................... 3
Typical Installation .......................................................... 3
Wiring Diagram ............................................................... 3

 

Quick connect instructions ...................................................... 3

Warranty .......................................................................... 4
 

LIMITED LIFETIME WARRANTY ................................................ 4

 

What is Covered...................................................................... 4

 

Pre-installation................................................................ 4
 

Planning Installation ................................................................ 4

 

Tools Required ........................................................................ 4

 

Hardware Included .................................................................. 5

 

Package Contents ................................................................... 5

Installation - New Construction .................................... 6
Installation - Existing Construction .............................. 8
Care and Maintenance ................................................. 11
Troubleshooting ............................................................ 11

Table of Contents

Safety Information

Please read and understand this entire manual before attempting to assemble, operate or install the 
product.

1.  Always disconnect the power supply prior to servicing the fan, motor or junction box.
2.  Installation work must be carried out by a qualified person(s) in accordance to all local and safety codes including the rules for fire-rated  

construction.

3.  Follow all local building, safety and electrical codes as well as NEC (National Electrical Code) and OSHA (Occupational Safety and Health Act).
4.  Electric Service supply must be 120 volts, 60 hertz.
5.  This unit must be properly grounded.
6.  Do not bend or kink the power wires.
7.  Exercise care to not damage existing wiring when cutting or drilling into walls or ceilings.
8.  Sufficient air supply is required for proper combustion and the exhaustion of gases through the chimney (flue) of fuel burning equipment  

to prevent back-drafting. See the standards of NFPA (National Fire Protection Association) and ASHRAE (American Society for Heating  
Refrigeration and Air Conditioning Engineers) and the local building code authorities.

9.  Do not use this fan with any solid state control device, such as a remote control, dimmer switch, or certain timers. Mechanical timers are  

not solid state devices.

10.  This ventilation fan is approved for use over a bathtub or shower when installed in a GFCI protected circuit. Do not use fans over a bathtub  

or shower that are not approved for that application and marked accordingly.

11.  Do not install in a cooking area.
12. 

Do not use to exhaust hazardous or explosive vapors.

13. 

Fans should always be vented to the exterior and in compliance with local codes.

14. 

Do not install in a ceiling with insulation greater than R40.

15. 

Duct work should be installed in a straight line with minimal bends.

16. 

Duct work size must be the same size as the discharge and should not be reduced. Reducing the duct size may increase fan noise.

17. 

Prior to service or cleaning this unit, shut off power supply at the panel and lock to prevent the power from being turned on. If the panel  
cannot be locked, clearly mark the panel with a warning tag to prevent the power from being turned on.

18. 

Use this unit in the manner intended by the manufacturer. If you have any questions. Please call customer service.

19. 

To reduce the risk of injury to persons, install the fan at least 7 feet (2.1m) above the foor.

20.

DOT USE rigid conduit when installation.

Содержание PT13-13D-1

Страница 1: ...rday 1 855 HD HAMPTON HAMPTONBAY COM THANK YOU We appreciate the trust and confidence you have placed in Hampton Bay through the purchase of this ventilating bath fan We strive to continually create q...

Страница 2: ...rafting See the standards of NFPA National Fire Protection Association and ASHRAE American Society for Heating Refrigeration and Air Conditioning Engineers and the local building code authorities 9 Do...

Страница 3: ...the connector on stranded wires Strip wires 3 8 1 2 Grip the wire firmly and push the stripped end of the wire into the open port of the connector Use only one conductor per port Verify the stripped...

Страница 4: ...an the purpose SHALL VOID THIS WARRANTY Shipping costs for return product as part of a claim on the warranty must be paid for by the customer Contact the Customer Service Team at 1 855 HD HAMPTON or v...

Страница 5: ...5 HAMPTONBAY COM Please contact 1 855 HD HAMPTON for further assistance Pre installation continued PACKAGE CONTENTS Part Description A Fan Body B Grille C Duct connector Quantity 1 1 1...

Страница 6: ...ount the fan housing to the joist using long wood screw where indicated Connect house and fan wires Pull the wire through the hole and into the junction box not included Using a quick connector secure...

Страница 7: ...ct not included and secure it with duct tape or clamps neither included Finish ceiling work The ceiling hole should be aligned with the edge of the fan housing 5 Install the grille Pinch the mounting...

Страница 8: ...iling opening Measure the opening to assure it is large enough to accom modate the new fan body A 7 50 in x 7 25 in NOTE 7 25 inch side of the opening should be flush with the joist 3 Enlarge the open...