1
Use and Care Guide
LED LOW VOLTAGE WELL LIGHT
PACKAGE CONTENTS
C – Wire Connector x1 (with 12 in.
A – Well Lights x 1 B – Housing x 1 wire attached to lamp body) D– Plastic plug x 4 E – Cover Screw x 4
Assembly and Installation
1
Buried the housing
2
Connecting the wires
NOTE
:
Do not use a hammer. If the ground is hard, use water to
soften it or a trowel to loosen the soil.
□
The well lamp (A) is pre-installed in housing (B), and it is need to use
a screwdriver to lift out the plastic plug (D) and screw out the cover
screw (E) to release the housing (B).
□
Choose a location to buried the housing (B) into the ground.
□
It is necessary to ensure that the wires are placed inside the housing
(B) to connect the power supply.
WARNING:
The wire connector (C) contacts have sharp edges for
piercing the main low voltage cable. To avoid injury, do not touch
the metal contacts.
CAUTION:
The wire from low voltage power unit should be 12-16
AWG type underground low Energy Circuit Cable.
IMPORTANT:
□
Protect the wiring by routing it in close proximity to the light
fitting, or next to a building structure such as a house or a
deck.
□
The landscape wire and connector can also be hidden under
stone or buried under grass at a maximum depth of 6 in.
(15.24 cm).
□
Do not install the fixture within 10 ft. of a pool, spa, or fountain.
□
Do not submerge the fixture in water.
□
Place the wire connector (C) on opposite sides of the low voltage
cable (sold separately) from the transformer (sold separately)
where the fixture will be located.
□
Align and fit the main low voltage cable vertically to the slot of the
wire connector (C).
□
Press the wire connector (C) together until it is locked around the
main low voltage cable. The pre-set prongs will pierce the cable
insulation and establish contact with the electrical wire inside.
□
Once the wire connector (C) is in place, wrap it with electrical tape
(sold separately).
□
After all fixtures are installed, turn on the transformer.
Item # 1008 556 345
Model # LBW5401LX-02