Hampton HG35-1 Direct Vent Freestanding Gas Stove

3)

  With the pipe attached to the stove, slide the 

stove into its correct location, and mark the 
wall for a 241mm x 241mm (inside dimen-
sions) square hole. The center of the square 
hole should line up with the centerline of 
the horizontal pipe, as shown in diagram 
3. Cut and frame the 241mm square hole 
in the exterior wall where the fl ue will be 
terminated. If the wall being penetrated is 
constructed of non-combustible material, 
i.e. masonry block or concrete, a 178mm 
diameter hole is acceptable.

INSTALLATION

DURA-VENT FLUEING 

COMPONENTS

The Simpson Dura-Vent Direct Vent System 
offers a complete line of component parts for 
installation of both horizontal and vertical installa-
tion. Many items are offered in decorative black, 
as well as galvanized fi nish. The galvanized pipe 
and fi ttings are used for concealed locations such 
as attics or where corrosion is a factor, such as 
above the roof line. Decorative brass trim kits 
are available for both wall thimbles and ceiling 
support boxes.  

Part # 

  Description

971 

Horiz. Termination Kit includes: 90

o

 black 

elbow, wall thimble cover, horiz. square 
termination cap, 24" black pipe, 11" -14" 
5/8" adjustable black pipe

970 Basic 

Horiz. Termination Kit includes: 90

o

 

black elbow, wall thimble cover, horiz.  
square term. cap

978 

Vert. Termination Kit includes 0/12 - 6/12 
pitch adjustable fl ashing, storm collar, 
low profi le term. cap

908B  6" Pipe Length-Black 
907B  9" Pipe Length-Black 
906 

12" Pipe Length Galv.

906B  12" Pipe Length-Black  
904 

24" Pipe Length Galv.

904B  24" Pipe Length-Black 
903 

36" Pipe Length Galv. 

903B  36" Pipe Length-Black 
902 

48" Pipe Length Galv.

902B  48" Pipe Length-Black 
911B  11"-14 5/8" Adj. Pipe Length-Black 
917B  17"- 24" Adj. Pipe Length Black 

945 45

Elbow Galv.

945B 45

O

 Elbow-Black 

945G 45

Elbow-Swivel Galv.

945BG 45

O

 Elbow-Swivel-Black 

990 90

Elbow Galv.

990B 90

O

 Elbow-Black 

990G 90

Elbow-Swivel Galv.

990BG 90

O

 Elbow-Swivel-Black 

991 

High Wind Term. Cap (Vertical)

980 Vertical 

Term. 

Cap

984 

Horiz. Sq. Term. Cap

985 

Horiz. Sq. High Wind Termination

 Cap
982 Snorkel-14" 

Rise 

Term.Cap

981 Snorkel-36" 

Rise 

Term.Cap

940 Wall 

Thimble-Support/Box 

941 Cathedral/Ceiling-Support/Box
3951  Brass Trim-WallThimble/Ceiling Sup-

port

963 Firestop 

Spacer

943 Flashing 

0/12-6/12

943S   Flashing 7/12-12/12
953 Storm 

Collar

950 

Vinyl Siding Standoff

988 Wall 

Strap 

942 Wall 

Thimble

Diagram 1: 

Hint: Apply 

silicone to 

female end.

DURA-VENT 

HORIZONTAL 

INSTALLATIONS

1)

  Set the unit in its desired location. Check 

to determine if wall studs or roof rafters are 
in the way when the venting system is at-
tached. If this is the case, you may want to 
adjust the location of the unit.

2)

  Direct Vent pipe and fi ttings 

are designed with special 
twist-lock connections to 
connect the fl ueing  sys-
tem to the appliance fl ue 
outlet. A twist-lock appli-
ance adapter is installed 
on the unit at the factory. 
Assemble the 
desired combi-
nation of pipe 
and elbows to 
the appliance 

 b)

  Horizontal runs of fl ue must be supported 

every three feet. Wall straps are available 
for this purpose.

 

Parts not supplied by Dura-Vent

946-506/P  Vent Guard (Optional)
640-530 

Riser Flue Terminal (Optional)

948-128 

Vinyl Siding Shield for Riser 

 Flue 

Terminal

946-228 Horizontal 

Square 

Termination 

 

 Cap

You will require the following components with 
your new  Direct Vent Freestanding Gas Stove. 
Please review your product to make sure you 
have everything you need. In the event that you 
are missing any part, contact your dealer. 

Note:  These are the minimum pieces re-

quired. Other parts may be required 
for your particular installation. See 
above for a list of fl ue parts.

If installing termination on a siding covered wall, 
a vinyl siding standoff or furring strips can be 
used in order to ensure that the termination is 
not recessed into siding.

The vinyl siding standoff is required for walls 
with vinyl siding.

Minimum components for a Dura-Vent
Horizontal Installation:

A)  Dura-Vent Horizontal Termination Kit
B)  Wall Thimble (required for combustible 

walls)

Minimum components for a Dura-Vent
Vertical Termination:

D) Dura-Vent Vertical Termination Kit. See 

above for pipe lengths.

 

adapter with pipe seams oriented towards 
the wall or ceiling, as much out of view as 
possible. The fi nal positioning of the pipe 
and 90

o

 elbow assembly is determined by 

the mounting orientation of the adapter on 
the stove and twist-locked for a solid con-
nection.

 

Note:

 a)

  Twist-lock procedure: Four indentations, 

located on the female ends of pipes and 
fi ttings, are designed to slide straight 
onto the male ends of adjacent pipes 
and fi ttings, by orienting the four pipe 
indentations so they match and slide in 
to the four entry slots on the male ends 
(diagram 1). Push the pipe sections 
completely  together, then twist-lock 
one section clockwise approximately 
one-quarter turn, until the two sections 
are fully locked. The female locking lugs 
will not be visible from the outside on 
the Black Pipe or fi ttings. They may be 
located by examining the inside of the 
female ends. Apply sealant "Mill-Pac" to 
inner pipe and high temp silicone sealant 
to outer pipe on every twist-lock joint.

Содержание HG35-LPG1

Страница 1: ...an authorized installer service agency or the gas supplier FOR YOUR SAFETY Do not store or use gasoline or other flam mable vapours and liquids in the vicinity of this or any other appliance Installa...

Страница 2: ...DUCTS INTERNATIONAL LTD The HG35 has been designed to provide you with all the warmth and charm of a wood fireplace As it also bears our own mark it promises to provide you with economy comfort and se...

Страница 3: ...ome Requirements 7 Combustion and Ventilation Air 7 Flueing Introduction 8 Installation Precautions 8 Safety Precautions for the Installer 8 Flue Restrictor Position 8 Exterior Flue Terminal Locations...

Страница 4: ...difference the label on the unit is the correct one DO NO T DO NO T DO NO T DO NO T DO NO T DO NO T OPERATE THIS APPLIANCE BEFORE READING THE INSTRUCTIONS BOOKLET PLACE ARTICLES ON OR AGAINST THIS AP...

Страница 5: ...D AWAY FROM FURNITURE AND DRAPERIES WARNING FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILLVOIDYOURWARRANTYAND MAY CAUSE A SERIOUS HOUSE FIRE CHILDREN AND ADULTS SHOULD BEALERTEDTOTHEHAZARDSOF HIGH S...

Страница 6: ...Clearances A Side Wall to Unit 6 1 2 165 mm B Back Wall to Unit 6 152 mm C Vertical Flue Pipe to Back Wall 2 50 mm E Unit Corner to Wall 2 50 mm Unit Top to Alcove Ceiling 36 914 mm Minimum ceiling h...

Страница 7: ...l as ensuring that there is adequate accessibility for servicing and proper operation INSTALLATION MANUFACTURED MOBILE HOME ADDITIONAL REQUIREMENTS 1 Ensure that structural members are not cut or weak...

Страница 8: ...ns in walls and ceilings FLUEING INTRODUCTION The HorizontalTermination Kit and the Simpson Dura Vent Direct Vent System Model DV GS venting systems in combination with the Direct Vent Freestanding Ga...

Страница 9: ...hanical air inlet or any other opening into a building with the exception of sub floor ventilation see also Note I Appliances up to 150 MJ h input 500 Appliances over 150 MJ h input 1500 k Vertically...

Страница 10: ...ations of vertical runs with horizontal terminations Maximum one 90O elbow two 45o elbows equal one 90o elbow ULPG LPG and Natural Gas Residential Manufactured and Mobile Homes Installations The fluei...

Страница 11: ...ns follownational or local code requirements Below Grade Riser Installation If the Riser Termination must be installed below grade i e basement application proper drain age must be provided to prevent...

Страница 12: ...eing Arrangements chart below for minimum and maximum flue lengths See chart below for minimumdistancesfromroof Periodicallycheck that the flue is unrestricted Masonry chimneys may take various contou...

Страница 13: ...5o elbow will seat onto both the starter collar and the 90o elbow Crimpedsectionofrigidpipe seats into the 90o elbow Only cut the uncrimped side of pipe Dismantle all pipe sections including flue term...

Страница 14: ...the liner onto the 4 dia starter collar 8 Cut the 4 dia flex liner to the desired size Hint leave an extra 12 to 16 of length this will make the final assembly easier to work with 9 Securethe4 dia fl...

Страница 15: ...imumclearancerequirementsbetween the outer wall of the flue pipe and nearby com bustible surfaces is 1 1 4 inch Be sure to check the flue termination clearance requirements fromdecks windows soffits g...

Страница 16: ...unit in its desired location Check to determine if wall studs or roof rafters are in the way when the venting system is at tached If this is the case you may want to adjust the location of the unit 2...

Страница 17: ...ue cap by attaching the two sheet metal strips extending from the flue cap assembly into the outer wall of the flue pipe Use the two sheet metal screws provided to connect the strips to the pipe Bend...

Страница 18: ...ion and sealed Diagram 8 5 Cut a hole in the roof centred on the small drilled hole placed in the roof in Step 2 The hole should be of sufficient size to meet the minimum requirements for clearance to...

Страница 19: ...n is attached to the support using the eight metal screws provided Be sure there is at least a 2 inch overlap where the extension joins the support CATHEDRAL CEILING Round Support RDS Square Support S...

Страница 20: ...be within the limits specified on the safety label 6 When finished reading manometer turn off the gas valve disconnect the hose and tighten the screw clockwise with a 1 8 flat screwdriver Note Screw...

Страница 21: ...908 528 Red LPG label 1 910 037 30 ULPG Pilot Orifice 1 918 579 Instruction Sheet 6 Pull out the pilot hood by hand 7 Remove the pilot orifice with the allen key 8 Put in the new LPG orifice with the...

Страница 22: ...outlet pressure and screw it out to decrease it Use a 10 mm wrench Note The outlet pressure must be set to maximum 2 64 kPa 17 Turn on the gas supply and plug in the power cord Cable Electric Modulat...

Страница 23: ...Burner Orifice 52 LPG 1 918 149 Decal Converted to 30 6 mj 1 918 148 Instruction Sheet 1 Shut off the gas supply 2 Open the front door Carefully remove the logs and lava rock Refer to manual for more...

Страница 24: ...2 154 Embers Embers The 02 refer numbers i e 02 43 are molded into the rear of each log 1 Carefully remove the logs from the box and unwrap them The logs are fragile handle with care do not force into...

Страница 25: ...proper light off make sure flame flows smoothly from one end of burner to the other If there is any flame hesitation check that area for any blockage of the burner port Cutout Pin D 02 46 B 02 56 A 0...

Страница 26: ...om the sides of the Front Casting 3 Fasten the Right Door to the 2 right hinges 2 screws per hinge Repeat for the Left Door TILE INSET INSTALLATION Side Tile Inset 1 Slide the Standard Side Tile Inset...

Страница 27: ...ff of the stove 2 Release the catches on the left and right side of the stove that secure the glass 3 Remove the glass by sliding it up and out 4 Pull all four door hinges out from the sides of the fr...

Страница 28: ...Grounding Instructions This appliance is equipped with a three pronged grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong recep...

Страница 29: ...losed to prevent possible shock 3 Check to ensure there are no gas leaks 4 Make sure the three pieces of door glass are properly positioned Never operate the appliance with any of the glass removed or...

Страница 30: ...button once will switch the unit on The unit will resume its last settings If the unit is switched on pressing and releasing this button once will switch the unit off Flame Increase If the unit is swi...

Страница 31: ...re provisions for adequate combustion and ventilation air 918 399a WARNING If you do not follow these instructions exactly afireorexplosionmayresultcausingproperty damage personal injury or loss of li...

Страница 32: ...AUTHORIZED SERVICE TECHNI CIAN TO INSPECT THE APPLI ANCE AND TO REPLACE ANY PARTOFCONTROLSYSTEMAND ANY GAS CONTROL WHICH HAS BEEN UNDER WATER WARNING CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZAR...

Страница 33: ...sed with broken logs Turn off the gas valve and allow the unit to cool before opening door to carefully remove the logs The pilot light generates enough heat to burn someone If for any reason a log sh...

Страница 34: ...the unit MUST NOT be operated without the fan access panel securely in place and correctly sealed IMPORTANT These fans collect a lot of dust from within your home Ensure you maintainthesefanmotorsona...

Страница 35: ...N A N A N A N A 910 084 Control Box 910 527 Manual Control Switch N A N A N A 910 080 Valve 910 521 Control Box Cable 1 910 522 Control Box Cable 2 910 523 Control Box Cable 3 2 N A 2 2 1 2 3 910 912...

Страница 36: ...5 740 048 Baffle for Firebox 46 Heat Exchanger Assy 47 Transition Box Assy 48 740 077 Side Insert Bracket Part Description Part Description Part Description 55 Gasket Transition Box Air Passage 56 W84...

Страница 37: ...Hampton HG35 1 Direct Vent Freestanding Gas Stove 37 PARTS LIST...

Страница 38: ...Pilot Holder 68 W840470 Pilot Assembly Gasket 69 Valve Shield 70 Valve Bracket 72 Front Support 73 730 528 Rear Log Bracket Assy 75 402 935 Log Set 740 572 Ember Package 78 746 525 Burner Assy 79 Bas...

Страница 39: ...ty to the original purchaser of a Regency Product The Warranty Lifetime Covered under the agreement are the following compo nents Combustion chamber heat exchanger burner tubes logs embers glass therm...

Страница 40: ...lled ______________________________________________________ Serial No __________________________________________________________ Register your Regency warranty online www regency fire com au Reasons t...

Отзывы: