HAMPTON BAY HBLG5000 Скачать руководство пользователя страница 10

Do not under any 
circumstances cut 
or remove the 
grounding prong 
from the plug.

Line Cord Plug

Use Wall Receptacle

Power Supply

Power supply cord with
3-prong grounding plug

Standard 125V, 3-wire grounding
receptacle rated 15A, 125V AC

Use 15 AMP, time
delay fuse or circuit 
breaker.

TYPE B

SASH SEAL

(TYPE E)

L BRACKET

TYPE A

DRAIN PIPE

DRAIN CAP

TYPE B

Support Bracket (TYPE G)

10

Features

and

Installation

Fig. 12

Fig. 13

Fig. 14

4. SECURE THE GUIDE PANELS

Extend the guide panels (TYPE F) to fill the window
opening using 4 screws (TYPE B) to secure them, as
shown in Fig. 12. 

5. INSTALL THE SASH SEAL AND SASH LOCK

a. Cut the sash seal (TYPE E) to the window width.

Stuff the sash seal between the glass and the
window to prevent air and insects from getting into
the room, as shown in Fig. 12.

b. Fasten  the  bracket using a screw (TYPE A), as

shown in Fig. 12.

6. a. Remove the screws that secure the cabinet and

base pan in the right side.

b. Fasten the suport bracket (TYPE G) using a

removed screw. Attach the suport bracket (TYPE G)
in the inner window sill with a screw (TYPE B), as
shown Fig. 13.

7. Window installation of room air conditioner is now

completed. See ELECTRICAL DATA for attaching
power cord to electrical outlet.

C. HOW TO SECURE THE DRAIN PIPE

In humid weather, excess water may cause the BASE
PAN to overflow. To drain the water, remove the
DRAIN CAP and secure the DRAIN PIPE to the rear
hole of the BASE PAN. (Fig. 14) Press the drain pipe
into the hole by pushing down and away from the fins
to avoid injury.

REMOVAL FROM WINDOW

Turn the air conditioner off, disconnect the power cord, remove the bracket, the screws and Support Bracket
installed through the top and bottom of the guide panels, and save for reinstallation later. Close the guide panels.
Keeping a firm grip on the air conditioner, raise the sash, and carefully tilt the air conditioner backward, draining
any condensate.  Lift the air conditioner from the window and remove the sash seal from between the windows.

USE OF EXTENSION CORDS

Because of potential safety hazards, we strongly discourage the use of an extension cord. However, if you wish to
use an extension cord, use a CSA certified/UL-listed 3-wire (grounding) extension cord, rated 15A, 125V.

Electrical  Data

Hang

Push

Содержание HBLG5000

Страница 1: ...ating your room air conditioner MODELS MODÉLES MODELOS HBLG5000 Veuillez lire attentivement et en entier ce guide d utilisation et les mesures de sécurité ci incluses avant de procéder à l installation et au fonctionnement de votre climatiseur Por favor lea las instrucciones de operación y las precauciones de seguridad cuidadosa y totalmente antes de instalar y operar su acondicionador de aire de ...

Страница 2: ...s to common problems in the chart of troubleshooting tips If you review our chart of Troubleshooting Tips first you may not need to call for service at all READ THIS MANUAL CAUTION Contact an Authorized Service Center for repair or maintenance of this unit Call 1 800 243 0000 to locate the nearest ASC The air conditioner is not intended for use by young children or invalids without supervision You...

Страница 3: ... shown below Be sure not to do this Be sure to follow the instructions Plug in the power plug properly Otherwise it will cause electric shock or fire due to heat generation Do not operate or stop the unit by inserting or pulling out the power plug It will cause electric shock or fire due to heat generation Do not damage or use an unspecified power cord It will cause electric shock or fire If the p...

Страница 4: ... dust to accumulate on the heat exchanger Do not put a pet or house plant where it will be exposed to direct air flow This could injure the pets or plants Do not use for special purposes Do not use this air conditioner to preserve precision devices food pets plants and art objects It may cause deterioration of quality etc Do not operate switches with wet hands It may cause an electric shock Do not...

Страница 5: ...re moderate cooling i e the higher number the greater cooling FOR NORMAL COOLING 1 Turn the operation switch to the High Cool or the Low Cool setting 2 Set the thermostat control to the desired temperature mark the mid point is a good starting position If the room temperature is not satisfactory after a reasonable time adjust the control to a cooler or warmer setting as appropriate FOR MAXIMUM COO...

Страница 6: ...etergent and lukewarm water then polished with Liquid Wax for Appliances To ensure continued peak efficiency the condenser coils outside of unit should be checked periodically and cleaned if clogged with soot or dirt from the atmosphere HOW TO REMOVE THE FRONT GRILLE 1 Remove the thermostat knob and the operation knob by pulling 2 Remove the screw securing the Front Grille Fig 3 3 Push the grille ...

Страница 7: ... parts name prior to installation will help you understand the installation procedure Features 1 CABINET 2 HORIZONTAL AIR DEFLECTOR 3 COOL AIR DISCHARGE 4 FRONT GRILLE 5 INLET GRILLE 6 AIR FILTER 7 KNOBS 8 AIR INTAKE 9 UPPER GUIDE Features and Installation ...

Страница 8: ...l 2 If storm window presents interference fasten a 2 wide wood strip to the inner window sill across the full width of the sill The wood strip should be thick enough to raise the height of the window sill so that the unit can be installed without interference by the storm window frame See Fig 5 2 The top of the wood strip should be approximately 3 4 higher than the storm window frame STORM WINDOW ...

Страница 9: ...ets behind the inner window sill with short side of bracket as shown Use the 2 screws TYPE A provided b The bracket helps to hold unit securely in place Be sure to place bracket edge flush against back of inner sill See Fig 9 3 INSTALL THE AIR CONDITIONER IN THE WINDOW a Carefully lift the air conditioner and slide it into the open window Make sure the bottom guide of the air conditioner drops int...

Страница 10: ... in the inner window sill with a screw TYPE B as shown Fig 13 7 Window installation of room air conditioner is now completed See ELECTRICAL DATA for attaching power cord to electrical outlet C HOW TO SECURE THE DRAIN PIPE In humid weather excess water may cause the BASE PAN to overflow To drain the water remove the DRAIN CAP and secure the DRAIN PIPE to the rear hole of the BASE PAN Fig 14 Press t...

Страница 11: ...rtains blinds or furniture blocking the front of the air conditioner Turn the knob to a higher number The highest setting provides maximum cooling Clean the filter at least every 2 weeks See the care and Maintenance section When the air conditioner is first turned on you need to allow time for the room to cool down Check for open furnace floor registers and cold air returns See Air Conditioner Fre...

Отзывы: