background image

 

Hampton

®

 H27-10 Direct Vent Freestanding Gas Stove

  |     

5

5

requirements

5.08: 

Modifications to NFPA-54, Chapter 10

(2) Revise 10.8.3 by adding the following additional requirements: 

(a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for 

residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than 

seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall 

be satisfied:  

1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled 

equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is 

installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery 

operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure 

served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of 

qualified licensed professionals for the installation of hard wired carbon monoxide detectors 

a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon 

monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level. 

b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of 

thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon 

monoxide detector with an alarm shall be installed. 

2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions 

shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.  

3. SIGNAGE. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight 

(8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The 

sign shall read, in print size no less than one-half (1/2) inch in size, 

"GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL 

OBSTRUCTIONS". 

4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation 

unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 

5.08(2)(a)1 through 4.  

(b) EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:  

1. The equipment listed in Chapter 10 entitled "Equipment Not Required To Be Vented" in the most current edition of NFPA 54 as adopted by 

the Board; and  

2. Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or 

structure used in whole or in part for residential purposes.  

(c) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product 

Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the 

instructions provided by the manufacturer for installation of the equipment and the venting system shall include: 

1. Detailed instructions for the installation of the venting system design or the venting system components; and 

2. A complete parts list for the venting system design or venting system.  

(d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a 

Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies 

"special venting systems", the following requirements shall be satisfied by the manufacturer: 

1. The referenced "special venting system" instructions shall be included with the appliance or equipment installation instructions; and  

2. The "special venting systems" shall be Product Approved by the Board, and the instructions for that system shall include a parts list and 

detailed installation instructions.  

(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, 

all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of 

the installation.  

MA Code - CO Detector

(for the State of Massachusetts only)

Содержание H27-NG10

Страница 1: ...mable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your bu...

Страница 2: ...has been designed to provide you with all the warmth and charm of a wood fireplace at the flick of a switch The model H27 10 has been approved by Warnock Hersey Intertek for both safety and efficiency...

Страница 3: ...System 21 DV Stove Horizontal Vent Kit 22 Residential And Manufactured Homes Mobile Homes 24 Minimum Horizontal Termination Installations 24 Dura Vent Termination Kit 25 Horizontal Terminations 26 Ve...

Страница 4: ...ight Side Wall Vertical Pipe See Manual for details Model Modele H27 NG10 Model Modele H27 LP10 Part 919 485a Colour Everything black on grey except for items indicated as being printed in red Size Pr...

Страница 5: ...directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT...

Страница 6: ...6 Hampton H27 10 Direct Vent Freestanding Gas Stove 6 dimensions UNIT DIMENSIONS WITH VERTICAL VENTING 17 13 16 452 mm...

Страница 7: ...Hampton H27 10 Direct Vent Freestanding Gas Stove 7 7 installation UNIT DIMENSIONS WITH HORIZONTAL VENTING 452 mm...

Страница 8: ...alfirst Consult the building authority having jurisdiction to determine the need for a permit prior to starting the installation Note Failure to follow the instructions could cause a malfunction of th...

Страница 9: ...f the appliance be kept clean and free from excessive lint from carpeting 4 See general construction and assembly in structions The appliance and vent should be enclosedwheninstalledinorpassingthrough...

Страница 10: ...wall if installing the blower option so the fan can be easily installed and or serviced LOCATING YOUR GAS STOVE When selecting a location for your stove ensure that the clearances listed above are met...

Страница 11: ...n the back of the left side access panel 7 Loosen the 2 bolts on fan assembly and slide the fan into the slots provided on the unit 8 Once the fan assembly is fitted into the assigned slots tighten th...

Страница 12: ...e steps OPTIONAL WALL THERMOSTAT INSTALLATION 1 Open the front panel and remove the cover plate by removing two screws 2 Disconnect one of the wires from the switch as shown in the picture below to co...

Страница 13: ...logy Co Axial system The inner liner vents products of combustion to the outside while the outer pipe draws outside combustion air into the combustion chambertherebyeliminatingtheneedtouseheated room...

Страница 14: ...of center line extended above meter regulator assembly 36 90cm a J Clearance to service regulator vent outlet 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air...

Страница 15: ...Adjustable Length 7 Black N A N A 4D7AB N A N A N A Extension Pipe 8 1 2 Galvanized 46DVA 08A N A N A N A N A N A Extension Pipe 8 1 2 Black 46DVA 08AB N A N A N A N A N A Adjustable Length 12 Galvani...

Страница 16: ...Termination Kit A Disc 4DT HKA 4DHTK2 4DHTKA SV SHK TM4 HTK Horizontal Termination Kit B 46DVA KHA Changed Components 4DT HKB 4DHTK1 4DHTKB SV HK TM4 HTK Vertical Termination Kit Disc 4DT VKC 4DHTK 4...

Страница 17: ...nt Direct Vent American Metal Products Ameri Vent Direct Vent Security Secure Vent Selkirk Direct Temp and ICC Excel AstroCapTM is a proprietary trademark of FPI Fireplace Products International Ltd D...

Страница 18: ...m two 45o elbows If the vent is ENCLOSED in a chase min size 9 x 9 maintain a 1 1 4 clearance to combustibles May be installed in Manufactured Mobile Homes after first sale Horizontal Terminations for...

Страница 19: ...of 8 feet total vertical and max 8 feet total horizontal Please note min 1 foot between 90o elbows is required With these options maxi mum total pipe length is 30 feet with minimum of 6 feet total ve...

Страница 20: ...feet total horizontal Please note min 1 foot between 90o elbows is re quired Vent restrictor position A fully open refer to the Vent Restrictor Position section Lengths do not include elbow indicated...

Страница 21: ...to be attached to two 3 76mm co linear aluminium flex running the full length of the chimney See the Venting Arrangements chart below for minimum and maximum flue lengths See chart below for minimumdi...

Страница 22: ...th the starter collar and the 90o elbow Crimped section of rigid pipe seats into the 90o elbow Only cut the uncrimped side of pipe Dismantle all pipe sections including vent terminal 2 Assembleatrialf...

Страница 23: ...and vinyl siding standoff to prevent water from entering and to make a tight seal between the cap and the standoff 7 Stretch the 4 dia flex liner out fully and get a trial fit of the liner onto the 4...

Страница 24: ...rements Determine the minimum clearance to combustibles from the rear of the unit to the wall It is also important to note the wall thickness Before cutting the vent hole through the wall ensure that...

Страница 25: ...ical to horizontal type installations Warning Alwaysmaintainrequired clearances air spaces to nearby combustibles to prevent a fire hazard Do not fill air spaces with insulation Theminimumclearancereq...

Страница 26: ...enetrated is constructed of non combustible material i e masonry block or concrete a 7 diameter hole is acceptable a The horizontal run of vent should have a 1 4 inch rise for every 1 foot of run towa...

Страница 27: ...dden on the final installation NOTE For best results and optimum performancewitheachapprovedventing system it is highly recommended to ap ply Mill Pac sealant supplied toevery inner pipe connection Fa...

Страница 28: ...lt in drafting or performance issues not covered under warranty 4 Assemble the desired lengths of black pipe and elbows necessary to reach from the appliance adapter up though the Round SupportBox Ins...

Страница 29: ...y chimneys cleanout doors and caps or plugs for cleanout tee fittings and ash dumps shall be secured in place and sealed before install ing a Direct Vent system within the chimney If the appliance shu...

Страница 30: ...Gas min 5 0 w c Propane min 12 0 w c Manifold Pressure Natural Gas 3 5 0 2 w c Propane 10 0 2 w c 8 Ensure vent is vertical and secure the base of the flashing to the roof with roofing rails slide sto...

Страница 31: ...the valve 1 Make sure the valve is in the OFF position 2 Loosen the IN and or OUT pressure tap s turning counterclockwise with a 1 8 wide flat screwdriver 3 Attach manometer to IN and or OUT pres sure...

Страница 32: ...ll off the pilot cap to expose the pilot orifice 6 Unscrew the pilot orifice with the allen key and replace with the LP pilot orifice in the kit and replace pilot cap 7 Remove burner orifice with a 1...

Страница 33: ...and refer to the dia grams Ifthelogsarebrokendonotusetheunituntiltheyare replaced Broken logs can interfere with the pilot operation The gas log kit Part 350 930 contains the following a Rear Log b L...

Страница 34: ...ftheburner in and around where the embers are placed Avoid stacking platinum embers 6 Place the center cross log D so it rests in the notch located on the top of the rear log position as shown below L...

Страница 35: ...ck for proper draft CAUTION Anyalterationtotheproductthatcausessooting orcarboningthatresultsindamagetotheexterior faciaisnottheresponsibilityofthemanufacturer BACK UP BATTERY In the event of a power...

Страница 36: ...ot surface and are away from sharp edges WARNING Electrical Grounding Instructions This appliance is equipped with a three pronged grounding plug for your protection against shock hazard and should be...

Страница 37: ...Hampton H27 10 Direct Vent Freestanding Gas Stove 37 37 operating instructions WIRING DIAGRAM WITH THERMOSTAT Thermostat Optional Millivolt...

Страница 38: ...ned Never operate the appliance with the glass removed 5 Verifythattheventingandcapareunobstructed 6 Verify log placement If the pilot cannot be seen when lighting the unit the logs have been incorrec...

Страница 39: ...oard will go into lock out The system will need to be reset as follows a Wait 5 minutes turn the system off by pressing the ON OFF button on the remote b After approximately 2 seconds turn on ON OFF s...

Страница 40: ...nsult a qualified installer service agency or gas supplier AVERTISSEMENT Quiconque ne respecte pas la lettre les instructions dans la pr sente notice risquede d clencher un incendie ou une explosion e...

Страница 41: ...at different rates resulting in some cracking and ticking sounds will be heard throughout the cycling process WARNING CHILDRENANDADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATUREAND...

Страница 42: ...ocheckmechanicalsupportssuch as Wall Straps or plumbers tape for rigidity 5 Verify proper operation after servicing LOG REPLACEMENT Theunitshouldneverbeusedwithbrokenlogs Turn off the gas valve and al...

Страница 43: ...o stove 4 Disconnect gas line to stove 5 Disconnect 3 8 NPT pipe from 90o elbow on valve or flex connector 6 Disconnect 3 wires from spark igniter assembly 7 Lift off the Cast Top and remove the Cast...

Страница 44: ...ctor 350 004 Baffle Plate for Firebox Part Description Part Description Part Description 350 022 Casting Mount Bracket Fan Air Divider 50 W260260 Top Relief Frame Gasket 51 942 117 Top Relief Frame 52...

Страница 45: ...Halogen Light Socket Assembly 910 997 Halogen Light Bulb 120 Volt 20 Watt JCD Bi Pin Gy6 35 910 157 P Blower Motor Only with Squirrel Cage 911 093 10 foot Extension Cord 911 027 Battery Holder W 9V Sn...

Страница 46: ...46 Hampton H27 10 Direct Vent Freestanding Gas Stove 46 notes...

Страница 47: ...d if requested It is the general practice of FPI to charge for larger higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated for manufactur...

Страница 48: ...________________________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial No ___...

Отзывы: