 H25-1 Direct Vent Freestanding Gas Stove

5

REQUIREMENTS 

5.08: 

Modifications to NFPA-54, Chapter 10

(2) Revise 10.8.3 by adding the following additional requirements: 

(a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for 
residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than 
seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall 
be satisfied:  

1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled 
equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is 
installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery 
operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure 
served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of 
qualified licensed professionals for the installation of hard wired carbon monoxide detectors 

a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon 
monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level. 

b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of 
thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon 
monoxide detector with an alarm shall be installed. 

2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions 
shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.  

3. SIGNAGE. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight 
(8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The 
sign shall read, in print size no less than one-half (1/2) inch in size, 

"GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL 

OBSTRUCTIONS". 

4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation 
unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 
5.08(2)(a)1 through 4.  

(b) EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:  

1. The equipment listed in Chapter 10 entitled "Equipment Not Required To Be Vented" in the most current edition of NFPA 54 as adopted by 
the Board; and  

2. Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or 
structure used in whole or in part for residential purposes.  

(c) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product 
Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the 
instructions provided by the manufacturer for installation of the equipment and the venting system shall include: 

1. Detailed instructions for the installation of the venting system design or the venting system components; and 

2. A complete parts list for the venting system design or venting system.  

(d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a 
Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies 
"special venting systems", the following requirements shall be satisfied by the manufacturer: 

1. The referenced "special venting system" instructions shall be included with the appliance or equipment installation instructions; and  

2. The "special venting systems" shall be Product Approved by the Board, and the instructions for that system shall include a parts list and 
detailed installation instructions.  

(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, 
all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of 
the installation.  

MA Code - CO Detector

(for the State of Massachusetts only)

Содержание H25-LP1

Страница 1: ...Y What to do if you smell gas Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Fol...

Страница 2: ...a hand crafted appliance and has been designed to provide you with all the warmth and charm of a wood replace at the ick of a switch The model H25 has been approved by Warnock Hersey for both safety a...

Страница 3: ...Residential and Manufactured Homes Mobile Homes 21 Minimum Horizontal Termination Installations 21 Dura Vent Termination Kit 22 Horizontal Terminations 23 Vertical Terminations 24 Converting Class A...

Страница 4: ...abel on the unit is the correct one For the State of Massachusetts installation and repair must be done by a plumber or gas tter licensed in the Commonwealth of Massachusetts For the State of Massachu...

Страница 5: ...directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT...

Страница 6: ...d manufactured USA only or mobile home where not prohibited by local codes This appliance is only for use with thetypeofgasindicatedontherating plate This appliance is not convert ible for use with ot...

Страница 7: ...ction 3 Setventrestrictor Refertothe VentRestric tor Position section 4 Install venting a Check all venting requirements See Vent Restrictor Position to Rigid Pipe Venting Systems sections b Vertical...

Страница 8: ...ction INSTALLATION OPTIONAL FAN INSTALLATION Fan Kit Contains Qty Description 1 Fan Assembly c w green wire attached 1 Thermodisc 1 power cord 2 2 1 4 x 20 hex nut 1 Fan Speed Control 1 Remove the rea...

Страница 9: ...stove and secure with the 2 supplied bolts 2 1 4 20 hex head 12 Before re attaching the rear access panel the valve wires and the fan wires need to be connected Re connect the red and grey valve wires...

Страница 10: ...Warnock Hersey Theseunitsusethe balanced ue technology Co Axial system The inner liner vents products ofcombustiontotheoutsidewhiletheouterpipe draws outside combustion air into the combus tion chambe...

Страница 11: ...ap min 12 30cm with Riser Vent min 6 15cm H Not to be installed above a meter regulator assembly within 3 90cm horizontally from the centerline of the regulator J Clearance to service regulator vent o...

Страница 12: ...4DT AJB N A N A N A Adjustable Length 17 24 Galvanized Disc See 46DV 16A 917 N A from FPI N A N A N A N A Adjustable Length 17 24 Black Disc See 46DV 16AB 917B N A N A N A SV4LBA24 Adjustable Length 7...

Страница 13: ...N A N A N A Mansonry Chimney Conversion Kit includes Cap Adapter 18 x18 Flashing 46DVA KCT 935 N A N A N A N A Wall Firestop 46DVA WFS 947 N A N A N A N A Colinear Flex Connectors 46DVA ADF 923F N A N...

Страница 14: ...ll as Simpson Dura Vent Direct Vent GS American Metal Products Ameri Vent Direct Vent Security Secure Vent Selkirk Direct Temp AstroCapTM is a proprietary trademark of FPI Fireplace Products Internati...

Страница 15: ...If the vent is ENCLOSED in a chase min size 9 x 9 maintain a 1 1 4 clearance to combustibles May be installed in Manufactured Mobile Homes after rst sale Horizontal Terminations for All Venting System...

Страница 16: ...feet total vertical and max 8 feet total horizontal Please note min 1 foot between 90o elbows is required With these options maxi mum total pipe length is 30 feet with minimum of 6 feet total vertical...

Страница 17: ...tween 90o elbows is re quired Option H H1 V A 2 Max 2 Min B 3 Max 3 Min C 4 Max 4 Min D 5 Max 5 Min E 6 Max 6 Min Withtheseoptions max total pipelengthis30feetwithmin of6feettotalverticalandmax 6 feet...

Страница 18: ...the Venting Arrangements chart below for minimum and maximum ue lengths See chart below for minimumdistancesfromroof Periodicallycheck that the vent is unrestricted Masonry chimneys may take various...

Страница 19: ...Attachthe 45o elbowtotherigid pipe and ensure that the pipe length when cut with the 45o elbow will seat onto both the starter collar and the 90o elbow Crimpedsectionofrigidpipe seats into the 90o elb...

Страница 20: ...to prevent water from entering and to make a tight seal between the cap and the standoff 7 Stretch the 4 dia ex liner out fully and get a trial t of the liner onto the 4 dia starter collar 8 Cut the...

Страница 21: ...ular requirements Determine the minimum clearance to combustibles from the rear of the unit to the wall It is also important to note the wall thickness Before cutting the vent hole through the wall en...

Страница 22: ...through a wall ceiling or at the ter mination where the use of a restop or wall thimble reduces the required clearance to 1 Be sure to check the vent termination clearance requirements from decks win...

Страница 23: ...s constructed of non combusti ble material i e masonry block or concrete a 7 diameter hole is acceptable Note a The horizontal run of vent should have a 1 4 inch rise for every 1 foot of run towards t...

Страница 24: ...stallation NOTE For best results and optimum performance with each approved vent ing system it is highly recommended to apply Mill Pac sealant supplied to every inner pipe connection Failure to do so...

Страница 25: ...ing or performance issues not covered under warranty Silicone red RTV is optional 4 Assemble the desired lengths of black pipe and elbows necessary to reach from the appliance adapter up though the Ro...

Страница 26: ...secured in place and sealed before installing a Direct Vent system within the chimney If the appliance shuts off during operation contact a quali ed service person to de termine if a negative pressur...

Страница 27: ...o the support using the eight metal screws provided Be sure there is at least a 2 inch overlap where the extension joins the support HIGH ELEVATION This unit is approved in Canada for altitude to 4500...

Страница 28: ...mits speci ed on the safety label 6 When nished reading manometer turn off the gas valve disconnect the hose and tighten the screw clockwise with a 1 8 at screwdriver Note Screw should be snug but do...

Страница 29: ...und 30 in 904 781 Velcro Hook Black Remove the 2 screws push Burner Assembly to the left and lift out 3 Pull off the pilot cap to expose the pilot ori ce Installation of the LPG Conversion Kit 1 Shut...

Страница 30: ...wn in Fig 4 rotate the screw clockwise until snug do not overtighten 13 Verify that if the conversion is from NG to LPG the screw must be re assembled with the red o ring visible Fig 5 14 Re assemble...

Страница 31: ...generator wire through the hole of the DC spark heat shield 2 First remove the Piezo Ignition Wire from the Piezo Ignitor Then remove the Piezo Ignitor from the control panel 7 Attach the ground wire...

Страница 32: ...r to the diagrams If the logs are broken do not use the unit until they are replaced Broken logs can interfere with the pilot operation The gas log kit contains the following a Rear Log b Left Side Fr...

Страница 33: ...ace at the front of the burner in and around where the embers are placed Avoid stacking platinum embers 7 Place the center cross log on the locating pin in the top of the rear log and position as show...

Страница 34: ...ximum wire length Note Preferableifthethermostatisinstalled on an interior wall Hampton offers an optional programmable thermostat but any 250 750 millivolt rated non anticipator type thermostat that...

Страница 35: ...needed for the fan blower operation Caution Ensure that the wires do not touch any hot surfaces and are away from sharp edges INSTALLATION FINAL CHECK Before leaving this unit with the customer the in...

Страница 36: ...ding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Do not cut or remove the grounding prong from this plug INSTALLATION F...

Страница 37: ...the glass while it is hot located at the top right hand corner rear of the stove 2 Turn gas control knob so indicator points to OFF position and allow 5 minutes for any gas in the combustion chamber t...

Страница 38: ...e knob will not push in or turn by hand don t try to repair it call a quali ed service technician Force or attempted repair may result in a re or explosion D Do not use this appliance if any part has...

Страница 39: ...t Body Firebox Different types and thicknesses of steel will expand and contract at different rates resulting in some cracking and ticking sounds will be heard throughout the cycling process WARNING C...

Страница 40: ...ngs have been disturbed and conse quently loosened Also check mechanical supports such as Wall Straps or plumbers tape for rigidity 5 Verify proper operation after servicing LOG REPLACEMENT The unit s...

Страница 41: ...alve assembly continue 14 Remove two 2 thermopile wires 15 Remove thermocouple with a 9 mm metric wrench 16 Remove pilot nut with an 11 mm wrench 17 Remove valve to ori ce nut with a 13 16 wrench 18 R...

Страница 42: ...ption Part Description Part Description 50 W260260 Top Relief Frame Gasket 51 942 117 Top Relief Frame 52 W260280 Top Relief Plate Gasket 53 770 066F Top Relief Plate 54 Capscrew 1 4 x 1 3 4 NC 55 Sid...

Страница 43: ...910 038 Pilot Assy S I T 3 ame NG 910 039 Pilot Assy S I T 3 ame LP 67 Pilot Holder 68 W840470 Pilot Assembly Gasket 69 Valve Shield 70 Valve Bracket 71 260 042 Valve Gasket 73 Valve Cover Plate 74 V...

Страница 44: ...________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________...

Страница 45: ...________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________...

Страница 46: ...________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________...

Страница 47: ...requested It is the general practice of FPI to charge for larger higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated for manufacturer d...

Страница 48: ...Serial No __________________________________________________________ Printed in Canada Hampton is a trademark of FPI Fireplace Products International Ltd Hampton replace products are designed with rel...

Отзывы: