HAMPTON BAY Greenfire GCi60-2 Скачать руководство пользователя страница 15

Installation

Installation

m

aSonry

 f

ireplace

 i

nStallation

:

A  non-combustible  manufactured 

hearth pad (min. 24 gauge galvanized 

steel or similar) must cover combustible 

flooring underneath, as well as 6” (150 

mm) in front of the heater and 6” (150 

mm) to the side of the heater.

1. Install the hearth pad.

2. Lock any existing fireplace dampers 

in the open position.

3. Set  leveling  leg  to  approximate 

height.

4. Connect  a  Exhaust  Starter  Quick 

Connect straight to the exhaust pipe.

5. This fireplace insert must be installed 

with a chimney liner of 4” diameter 

extending  a  minimum  of  3’  from 

the  fireplace  insert  to  the  4”  to  6” 

increaser.  A  5.5  or  6  inch  stainless 

steel liner is then attached to the 

4” to 6” increaser to the top of the 

chimney.    The  chimney  liner  must 

conform to the Class 3 requirements 

of  CAN/ULC-S635,  Standard  for 

Lining Systems for Existing Masonry 

or Factory-Built Chimneys and Vents, 

or  CAN/ULC-S640,  Standard  for 

Lining  Systems  for  New  Masonry 

Chimneys.

6. It is necessary to permanently seal 

any opening between the masonry of 

the fireplace and the facing masonry.

Figure 9: Masonry fireplace installation. 

When installing the insert into a masonry fireplace, DO NOT remove any bricks or masonry, with the 

following exception: masonry or steel, including the damper plate, may be removed from the smoke

shelf and adjacent damper frame, if necessary, to accommodate a chimney liner. Do this only if their 

removal will not weaken the structure of the fireplace and chimney, and will not reduce protection for 

combustible  materials  to  less  than  that  required  by  the  national  building  code.  When  installing  the 

fireplace insert into a zero clearance fireplace, 

DO NOT

 cut or modify any factory firebox parts. 

Installation requirements when meeting the 78% (HHV)

A 4’’ chimney liner is affixed to a  4” to 6” increaser & either a 5.5” or 6” liner taken from the increaser 

to the top of the chimney. See diagram below.

Installation

Installation

M

AS ONRY

 F

IREPLACE

 I

NS TALLATION

:

A  non-combustible  manufactured 

hearth pad (min. 24 gauge galvanized 

steel or similar) must cover combustible 

flooring underneath, as well as 6” (150 

mm) in front of the heater and 6” (150 

mm) to the side of the heater.
1. Install the hearth pad.

2. Lock any existing fireplace dampers 

in the open position.

3. Set  leveling  leg  to  approximate 

height.

4. Connect  a  Exhaust  Starter  Quick 

Connect straight to the exhaust pipe.

5. This fireplace insert must be installed 

with a chimney liner of 4” diameter 

extending  a  minimum  of  3’  from 

the  fireplace  insert  to  the  4”  to  6” 

increaser.  A  5.5  or  6  inch  stainless 

steel  liner  is  then  attached  to  the 

4” to 6” increaser to the top of the 

chimney.    The  chimney  liner  must 

conform to the Class 3 requirements 

of  CAN/ULC-S635,  Standard  for 

Lining Systems for Existing Masonry 

or Factory-Built Chimneys and Vents, 

or  CAN/ULC-S640,  Standard  for 

Lining  Systems  for  New  Masonry 

Chimneys.

6. It is necessary to permanently seal 

any opening between the masonry of 

the fireplace and the facing masonry.

Figure 9: Masonry fireplace installation. 

When installing the insert into a masonry fireplace, DO NOT remove any bricks or masonry, with the 

following exception: masonry or steel, including the damper plate, may be removed from the smoke

shelf and adjacent damper frame, if necessary, to accommodate a chimney liner. Do this only if their 

removal will not weaken the structure of the fireplace and chimney, and will not reduce protection for 

combustible  materials  to  less  than  that  required  by  the  national  building  code.  When  installing  the 

fireplace insert into a zero clearance fireplace, 

DO NOT

 cut or modify any factory firebox parts. 

Installation requirements when meeting the 78% (HHV)

to the top of the chimney. See diagram below.

Floor Protection

Combustible Floor

Masonry Fireplace

Min 6" 

(150 mm)

Rain Cap

Steel Plate or Flashing

Flexible or Rigid 4"

Stainless Steel Liner

12" (30.5cm) Mantle

Minimum 36" (91 cm) 

from Bottom of stove

Damper Removed

or Fastened Open

Surround Panel

Flexible stainless 

steel pipe 

connection

Flexible or Rigid 5.5’’ or 6’’

Stainless Steel Liner

4’’ to 6’’ Stainless Steel

Increaser

3’ minimum of 4’’ 

Hampton GCi60-2 Cast Pellet Insert Technical Manual

15

Hampton GCi60-2 Cast Pellet Insert Technical Manual

15

Содержание Greenfire GCi60-2

Страница 1: ...storeorusegasolineorother flammable vapours and liquids in the vicinity of this or any other appliance Installation and service must be performed by an authorized installer or service agency Tested by...

Страница 2: ...ual for further information Note The 78 HHV when tested was achieved burning wood pellets only FIRE EXTINGUISHER AND SMOKE DETECTION All home with a pellet burning stove should have at least one fire...

Страница 3: ...s 11 Minimum Fireplace Opening 11 Vent Termination Requirements 12 Outside Fresh Air Connection 13 Exhaust And Fresh Air Intake Locations 13 Masonry Fireplace Installation 14 Positive Flue Connection...

Страница 4: ...until you are certain the chimney and its lining have not been damaged OPERATION The door and ash drawer must be kept closed when the unit is in operation to prevent fume spillage and for proper and s...

Страница 5: ...tributing plate must be taken to achieve it DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE FRESH AIR This...

Страница 6: ...ombustible materials Les d gagements minimums aux mat riels combustibles This pellet heater needs periodic inspection and repair for proper operation Consult the owner s manual for further information...

Страница 7: ...r Capacity Consumption on Low 60 Hz up to 60 lb 36 3 Kg 1 5 lb hr 0 68 Kg hr Testing Standard Weight with full hopper Consumption on High ASTM 1509 04 500 lb 227 Kg 6 5 lb hr 2 95 Kg hr Note Consumpti...

Страница 8: ...ecommended Fresh Air must be connected to all units installed in Mobile and Air Tight Homes R2000 or where required by local codes 7 Do not obtain combustion air from an attic garage or any unventilat...

Страница 9: ...onry bricks may be placed under the frame 4 Once level position the Insert Frame in the fireplace cavity so that the Surround Panel is flush with the front of the fireplace 5 Adjust the top anchor bol...

Страница 10: ...72 6 1 6 3DUW HVFULSWLRQ 6 7 2 Thermostat Installation 1 Install the wall thermostat millivolt rated thermostat recommended or a 12 24 Volt rated thermostat set to millivolts in a location that is not...

Страница 11: ...51 mm C Bottom of unit to an unshielded 12 305 mm mantle Le fond de l unit un manteau de chemin e non blind 33 838 mm D Unit to top facing protruding 19 mm De l unit au sommet du parement 0 0 mm E Uni...

Страница 12: ...erior vent termination locations Table 2 Use in conjunction with Figure 6 for allowable exterior vent termination locations Letter Minimum Clearance Description A 24 in 61 cm Above grass top of plants...

Страница 13: ...nd mobile homes When connecting to an outside fresh air source do not use plastic or combustible pipe A 3 minimum 76 mm ID inside diameter steel aluminum or copper pipe or ducting should be used The i...

Страница 14: ...to permanently seal any opening between the masonry of the fireplace and the facing masonry Figure 9 Masonry fireplace installation When installing the insert into a masonry fireplace DO NOT remove a...

Страница 15: ...ustible manufactured hearth pad min 24 gauge galvanized steel or similar must cover combustible flooring underneath as well as 6 150 mm in front of the heater and 6 150 mm to the side of the heater 1...

Страница 16: ...tering the chimney which will affect proper drafting of appliance Figure 10 Masonry fireplace positive flue installation A qualified installer should evaluate the existing fireplace to determine the b...

Страница 17: ...with sheet metal studs and have no combustible material in the air space All venting for Built In installation must use PL or L venting and be installed with vent manufacturer s recommended clearances...

Страница 18: ...d the structure Follow vent manufacturer guidelines for installation clearance to combustibles and sealing of venting High temp Sealant must be used when connecting vent pipe to the unit s starter pip...

Страница 19: ...12 Venting horizontally with rise NOTE This venting configuration is only for use with the Built In installation Wall framing Wall thimble Termination cap Vertical section of vent pipe Clean out tee...

Страница 20: ...tee Make sure that you install support brackets to keep the vent straight and secure All joints in the exhaust venting system must be fastened with at least three 3 screws 3 Install ceiling thimble an...

Страница 21: ...stem must be fastened with at least three 3 screws 3 Install ceiling thimble and secure the flashing as you go through the roof 4 Ensure that the rain cap is a minimum of 24 61 cm above the roof NOTE...

Страница 22: ...fuel qualities Refer to the Owners Manual for circuit board operation If after long periods of burning the fire builds up or there is a build up of clinkers this would be a sign that the fuel quality...

Страница 23: ...flashing unit may be out of fuel Check the Door and Ash Pan door THEY MUST BE CLOSED TIGHT See section 8 The Fuel will not light Check the fuse on the circuit board If the unit still does not start c...

Страница 24: ...aust motor will not function normally and 5 Unit is on but auger does not turn at all for more suggestions Severe negative pressure in area where unit is installed Check the operation by opening a win...

Страница 25: ...l settings Heat Level have no effect on the fire Check the line fuse to see if it has blown Check position of the Thermostat slide switch on the Circuit Board If there is no control of the Heat Level...

Страница 26: ...White Grey Grey White Blue Yellow Auger Motor White Yellow Vacuum Switch Connect Thermostat Here Brown Brown Blue Purple Yellow Red Thermostat Combustion Blower Black Black White Green Ground 120V Gr...

Страница 27: ...T MOTOR CAPACITOR C W STRAP GC60 017 16 AGITATOR DRIVE SHAFT W SPROCKET GC60 008 17 MOTOR DRIVE SPROCKET GC60 009 18 AUGER MOTOR 1 RPM GF55 001 19 GCI60 COMBUSTION BLOWER W HOUSING MOUNT GASKET GCI60...

Страница 28: ...GCI60 006 50 PED ASHPAN GASKET 10 GF55 020 51 ASH PAN GCI60 007 52 10 INCH DRAWER SLIDES WITH BRACKET SET OF 2 GCI60 034 53 22 INCH DRAWER SLIDES SET OF 2 GCI60 036 54 BEARINGS WITH MOUNTING BOLTS SET...

Страница 29: ...GCI60 Cast Surround Left CHARCOAL GCI60 251 70 GCI60 Cast Surround Right CHARCOAL GCI60 261 71 GCI60 Cast Surround Top Left CHARCOAL GCI60 271 72 GCI60 Cast Surround Top Right CHARCOAL GCI60 281 73 G...

Страница 30: ...Parts Diagram Components 6 48 1 2 3 4 8 23 14 10 11 15 9 29 21 7 42 24 12 54 25 17 16 18 40 5 22 45 41 49 47 52 53 13 19 20 37 47 75 Hampton GCi60 2 Cast Pellet Insert Technical Manual 30...

Страница 31: ...Parts Diagram Steel 69 70 38 28 57 26 27 63 5 62 61 36 51 59 66 67 68 64 65 30 37 39 44 71 72 73 75 74 Hampton GCi60 2 Cast Pellet Insert Technical Manual 31...

Страница 32: ...facture or FPI factory assembled components only unless herein specified otherwise Any part s found to be defective during the warranty period as outlined above will be repaired or replaced at FPI s o...

Страница 33: ...s cardboard coal or coal products oil based products waxed cartons compressed pre manufactured logs lack of regular maintenance and upkeep acts of God weather related problems from hurricanes tornados...

Страница 34: ...ir local provincial or national legal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtai...

Страница 35: ...in order for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product De...

Страница 36: ...Hampton GCi60 2 Cast Pellet Insert Technical Manual 36 WARRANTY...

Страница 37: ..._____________________________________________________________ ____________________________________________________________________ ____________________________________________________________________...

Страница 38: ..._____________________________________________________________ ____________________________________________________________________ ____________________________________________________________________...

Страница 39: ...Hampton GCi60 2 Cast Pellet Insert Technical Manual 39...

Страница 40: ...taller Please complete the following information Dealer Name Address ________________________________________ ___________________________________________________________ Installer ____________________...

Отзывы: