HAMPTON BAY Greenfire GC60 Скачать руководство пользователя страница 19

Installation

S

LIDER

/D

AMPER

 S

ET

-U

P

:

This is used to regulate the airflow through the pellet stove. 

Convection 
Fan

Slider 
Damper

Slider Damper 
Set Screw with 

5

/

16

" Hex Head

Removable Plate 
& Exhaust Sensor 
location 

Combustion 
Blower

Note: The side panel, 
& back grill are 
removed for clarity.

Figure 19: Slider/Damper Plate & Rod in Unit.

This unit is designed to operate within a negative pressure range 

of 

0.15-0.17 inches of water column (37-42 Pa). (See 

image on right for location to measure negative pressure 

test port).  

 This can be measured using a Magnahelic pressure 

gauge once the unit has been running on heat level 5 setting after 

one hour of burn time. This adjustment is necessary for varying 

venting configurations.  The reading can be taken from the 

” hole located on the right side of the Ash Box.  

The Combustion Trim, Feed Trim and Fuel Type Functions  can be used to compensate for varying fuel qualities. Refer 

to the Owners Manual for circuit board operation.
If, after long periods of burning, the fire builds up or there is a build up of clinkers, this would be a sign that the fuel 

quality is poor - this requires more air. 
The easiest way to make sure that an efficient flame is achieved is to understand the characteristics of the fire. 

•  A tall, lazy flame with dark orange tips requires more air.

•  A short, brisk flame, like a blowtorch, has too much air .

•  If the flame is in the middle of these two characteristics with a bright yellow/orange, active flame with no black tips 

then the air is set for proper operation, refer to Figure 20. 

SPECIAL NOTES:

 

Fuel quality is a major factor in how the stove will operate. If the fuel has a high moisture content or ash content the 

fire will be less efficient and has a higher possibility of the fire building up and creating clinkers (hard ash build-up).

A

Negative Pressure

Testing Port

Hampton GC60 Cast Pellet Stove Technical Manual

19

Содержание Greenfire GC60

Страница 1: ...a V4G 1H4 GC60 080 02 17 14 GC60 WARNING Improper installation adjustment alteration service or maintenance can cause injury property damage or loss of life Refer to this manual For assistance or addi...

Страница 2: ...result For your safety follow the installation instructions contact local building fire officials or authority having jurisdiction about restrictions and installation inspection requirements in your a...

Страница 3: ...Locations 11 Mobile Home Installation 12 Corner Through Wall Installation 12 Horizontal Exhaust Through Wall Installation 13 RECOMMENDED Through Wall With Vertical Rise and Horizontal Termination Ins...

Страница 4: ...ed to clean to be safe OPERATION The door and ash drawer must be kept closed when the unit is in operation to prevent fume spillage and for proper and safe operation of the pellet stove Also ensure al...

Страница 5: ...uction doesn t meet load capacity suitable measures e g load distributing plate must be taken to achieve it DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT DO NOT CONNECT THIS...

Страница 6: ...of floor protection in front of and to the sides of the door opening Serial No No De Seri To Start Stove Select fuel type mode PREMIUM PELLETS for superior quality pellet fuel REGULAR PELLETS for all...

Страница 7: ...ellet Heater 6mm dia Pellets wood corn wheat barley Voltage Current Max Power 110 120 V 4 2 Amps 504 Watts Frequency Hopper Capacity Consumption on Low 60 Hz up to 60 lb 36 3 Kg 1 5 lb hr 0 68 Kg hr T...

Страница 8: ...y onto carpet If it is to be installed on a carpeted area a solid surface wood metal or approved hearth pad must be installed between the unit and the carpet 6 This unit uses large quantities of air f...

Страница 9: ...the sides of the door opening Figure 4 GC60 Clearance to Combustibles THERMOSTAT INSTALLATION 1 Install the wall thermostat millivolt rated thermostat recommended or a 12 24 Volt rated thermostat set...

Страница 10: ...xterior vent termination locations Table 2 Use in conjunction with Figure 6 for allowable exterior vent termination locations Letter Minimum Clearance Description A 24 in 61 cm Above grass top of plan...

Страница 11: ...rtight homes and mobile homes When connecting to an outside fresh air source do not use plastic or combustible pipe A 3 minimum 76 mm ID inside diameter steel aluminum or copper pipe or ducting should...

Страница 12: ...ectrically grounded to the chassis of your home permanently Do not install in a room people sleep in Outside fresh air is mandatory Secure outside air connections directly to fresh air intake pipe and...

Страница 13: ...ned with at least three 3 screws 1 Place the appliance 15 37 5 cm away from the wall If the stove will be installed on a hearth pad set the unit on it 2 Locate the center of the exhaust pipe on the st...

Страница 14: ...152 cm of vertical pipe in the system to help naturally draft the unit in the event of extreme weather or a power outage Some horizontal through wall installations may require a T and 3 to 5 feet 91...

Страница 15: ...r thimble 4 90 Elbow Vertical section of 4 pipe Wall Thimble 4 45 Elbow with screen or Termination Cap Installation to use if there is a concrete or retaining wall in line with exhaust vent on pellet...

Страница 16: ...INSTALLATIONS section and then finish it by performing the following refer to Figure 15 1 Install a tee with clean out on the outside of the house 2 Install PL vent upward from the tee Make sure that...

Страница 17: ...installed vertically it will meet the minimum clearance from a combustible wall stated by the vent manufacturer 2 Install the tee with clean out 3 Install the pellet vent upward from tee When you reac...

Страница 18: ...xist fresh air intake can be taken through back of the fireplace or through the ash dump Installation HEARTH MOUNT INSTALLATION Figure 17 Hearth Mount Side View Figure 18 Hearth Mount Over View 1 Lock...

Страница 19: ...ype Functions can be used to compensate for varying fuel qualities Refer to the Owners Manual for circuit board operation If after long periods of burning the fire builds up or there is a build up of...

Страница 20: ...ng unit may be out of fuel Check the Door and Ash Pan door THEY MUST BE CLOSED TIGHT See section 8 The Fuel will not light Check the fuse on the circuit board If the unit still does not start contact...

Страница 21: ...e termination into a low pressure zone To reset Circuit Board after a trouble code push the ON OFF button 5 Unit is on but auger motor does not turn at all Check the line fuse to see if it has blown C...

Страница 22: ...es out and leaves fresh unburned fuel in the burn pot liner the fire is going out before the stove shuts off Trim the combustion air down to decrease the magnahelic pressure Turn the Heat Level up sli...

Страница 23: ...ge White Grey Grey White Blue Yellow Auger Motor White Yellow Vacuum Switch Connect Thermostat Here Brown Brown Blue Purple Yellow Red Thermostat Combustion Blower Black Black White Green Ground 120V...

Страница 24: ...t shown LATCH BOLT ROLLERS C W NUT GC60 031 not shown 2 AMP SMALL FUSE GC60 032 not shown 4 AMP SMALL FUSE IGNITOR GC60 033 not shown ADJ AUGER FEED COVER KIT N C PRE NOV 2010 GC60 034 not shown COMBU...

Страница 25: ...FIREBOX LOWER GC60 045 31 GC60 CONTROL PANEL WITH DECAL GC60 055 32 DAUGHTER BOARD GC60 022 33 MOTHER BOARD GC60 023 39 ASH PAN GC60 046 40 GLASS GC60 024 42 DOOR COMPLETE GC60 026 43 AUGER TUBE COVER...

Страница 26: ...arts Diagram Components 26 22 48 19 54 1 52 55 2 53 23 25 10 44 32 33 11 24 4 9 6 3 12 21 20 40 50 31 39 42 47 15 8 7 49 56 43 51 5 14 16 27 46 17 45 Hampton GC60 Cast Pellet Stove Technical Manual 26...

Страница 27: ...COAL GC60 221 60 GC60 CAST LEG CHARCOAL GC60 231 61 GC60 CAST SIDE LEFT CHARCOAL GC60 241 62 GC60 CAST SIDE RIGHT CHARCOAL GC60 251 63 GC60 CAST LEG LIP LEFT CHARCOAL GC60 261 64 GC60 CAST LEG LIP RIG...

Страница 28: ...efects in materials and workmanship for part repair or replacement for the first three 3 years and limited labour for the first two 2 years to the original purchaser Please see the exclusions and limi...

Страница 29: ...zed Hampton dealer before installation 10 FPI will not be responsible for inadequate performance caused by environmental conditions or use of any fuel other than certified wood pellets 11 The Limited...

Страница 30: ...to replace or repair items under this Limited Warranty will be covered per our warranty service fee reimbursement schedule Labour rates are set per component and as such total labour costs may not be...

Страница 31: ...__________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ _________________________...

Страница 32: ..._______ Installer ___________________________________________________________ Phone ___________________________________________________________ Date Installed _________________________________________...

Отзывы: