background image

Hampton GCI60 Cast Pellet Insert Owner's Manual

16

WARRANTY

Exclusions and limitations:

1.  This Warranty does not cover tarnish, discoloration or wear on the plating or paint.  

2.  This Warranty excludes wear and tear or breakage caused by cleaning, moving or service on log set.

3.  A qualified installer must install this stove or fireplace. This Limited Warranty covers defects in materials and workmanship only 

if the product has been installed in accordance with local building and fire codes; in their absence, refer to the owner’s manual. 

If the product is damaged or broken as a result of any alteration, willful abuse, mishandling, accident, neglect, or misuse of the 

product, the Limited Warranty does not apply.

4.  The stove must be operated and maintained at all times in accordance with the instructions in the Owner’s Manual. If the unit 

shows signs of neglect or misuse, it is not covered under the terms of this Warranty policy. Performance problems due to operator 

error will not be covered by the Limited Warranty policy.

5.  As this is a heating appliance some changes in colour of surface finishes may occur. This is not a flaw and as such is not covered 

under this warranty. 

6.  Some minor expansion, contraction, or movement of certain parts and resulting noise, is normal and not a defect and therefore, 

is not covered under this Limited Warranty. 

7.  Misuse includes over-firing. Over-firing this appliance can cause serious damage and will nullify the Limited Warranty.

8.  The Limited Warranty will cover glass thermal breakage only and will not cover misuse of the stove glass, including but not limited 

to glass that is struck, has surface contaminates or has had harsh or abrasive cleaners used on it.

9.  This warranty does not cover products made or provided by other manufacturers and used in conjunction with the operation of 

this stove without prior authorization from FPI The use of such products may nullify the Limited Warranty on this stove. If unsure 

as to the extent of this Limited Warranty, contact your authorized Hampton dealer before installation.

10. FPI will not be responsible for inadequate performance caused by environmental conditions, or use of any fuel other than certified 

wood pellets.

11. The Limited Warranty does not cover installation and operational related problems such as spillage caused by environmental 

conditions. Environmental conditions include but are not limited to nearby trees, buildings, roof tops, wind, hills, mountains, inad-

equate venting or ventilation, excessive offsets, negative air pressures or other influences caused by mechanical systems such 

as furnaces, fans, clothes dryers etc.

12. The Limited Warranty is void if:

  a) The stove has been operated in atmospheres contaminated by chlorine, fluorine or other damaging chemicals.

   b) The stove is subject to submersion in water or prolonged periods of dampness or condensation.

  c) Any damage to the unit, combustion chamber or other components due to water, or weather damage which is the result of, but 

not limited to, improper chimney/venting installation.

  c) Salt air in coastal areas or high humidity can be corrosive to the finish; these environments can cause rusting. Damage caused 

by salt air or high humidity is not covered by the Limited Warranty.

13.Exclusions to the Limited Warranty include: injury, loss of use, damage, failure to function due to accident, negligence, misuse, 

improper installation, alteration or adjustment of the manufacturer’s settings of components, lack of proper and regular mainte-

nance, alteration, or act of God.

14. The Limited Warranty does not cover damage caused to the fireplace or stove while in transit. If this occurs, do not operate the 

stove and contact your courier and/or dealer.

15. The Limited Warranty does not extend to or include firebox paint, door or glass gaskets with damage caused by normal wear and 

tear, or exterior paint discoloration or chipping, worn gaskets, etc.

16. The Limited Warranty does not include damage to the unit caused by abuse, improper installation, or modification of the unit.

WARRANTY

Содержание GCI60

Страница 1: ...and service must be performed by an authorized installer or service agency Tested by IMPORTANT SAVE THESE INSTRUCTIONS Contact your building or fire officials about restrictions and installation insp...

Страница 2: ...ve any questions about your product that are not covered in this manual please contact the HAMPTON DEALER in your area Safety Note If this stove is not properly installed a house fire may result For y...

Страница 3: ...sions Specifications 6 Control Board Functions 7 Automatic Safety Features of Your Pellet Stove 7 Operating Your Pellet Stove 8 Turning Your Pellet Stove Off 9 Slider Damper Set Up 9 Routine Cleaning...

Страница 4: ...cleaned daily A low ash fuel may allow longer intervals between cleaning CLINKERING clinkers are silica sand or other impurities in the fuel that will form a hard mass during the burning process This...

Страница 5: ...s lining have not been damaged OPERATION The door and ash drawer must be kept closed when the unit is in operation to prevent fume spillage and for proper and safe operation of the pellet stove Also e...

Страница 6: ...ributing plate must be taken to achieve it DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE FRESH AIR This u...

Страница 7: ...ood corn wheat barley Voltage Current Max Power 110 120 V 4 2 Amps 504 Watts Frequency Hopper Capacity Consumption on Low 60 Hz up to 50 lb 22 7 Kg 1 5 lb hr 0 68 Kg hr Testing Standard Weight with fu...

Страница 8: ...WN Heat Level Arrow to adjust setting 3 Light is the default setting Depending on Fuel quality Ignition problems may occur at higher altitudes this can be resolved by trimming the Combustion Fan to a...

Страница 9: ...it will switch to the designated heat setting Once a fire has been established the convection blower will turn on after ten minutes To OPERATE Press the Heat Level buttons to change the desired Heat L...

Страница 10: ...s can be measured using a Magnahelic pressure gauge once the unit has been running on heat level 5 setting after one hour of burn time This adjustment is necessary for varying venting configurations T...

Страница 11: ...ks at the right rotate the top of the agitator towards the back of the firebox to unlock it slide it to the left and lift it out of the burn pot liner 4 Lift the burn pot liner out of the stove 5 Lift...

Страница 12: ...extended use the gasketing may come loose To repair this glue the gasketing on using high temperature fiberglass gasket glue available from your local dealer This is important to maintain an airtight...

Страница 13: ...ished using the pellet appliance for the season unplug the stove for added electrical protection It is very important that the stove be cleaned and serviced as stated above CLEANING PAINTED SURFACES P...

Страница 14: ...1 Remove Cast Ash Drawer Front 2 Slide open the Cast Top 3 Lift off Cast Sides 4 Clip Side Rails to unit 5 Attach Front Rail using the quick release pins as shown in Fig 12 6 Adjust leg height and lo...

Страница 15: ...efects in materials and workmanship for part repair or replacement for the first three 3 years and limited labour for the first two 2 years to the original purchaser Please see the exclusions and limi...

Страница 16: ...fy the Limited Warranty on this stove If unsure as to the extent of this Limited Warranty contact your authorized Hampton dealer before installation 10 FPI will not be responsible for inadequate perfo...

Страница 17: ...to replace or repair items under this Limited Warranty will be covered per our warranty service fee reimbursement schedule Labour rates are set per component and as such total labour costs may not be...

Страница 18: ...______ Installer ____________________________________________________________ Phone ____________________________________________________________ Date Installed ________________________________________...

Отзывы: