HAMPTON BAY CALTRIS AK382HG-MBK Скачать руководство пользователя страница 2

Table of Contents  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Safety Information  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Warranty  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pre-installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Assembly  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Care and Cleaning  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Troubleshooting  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2

Table of Contents

2
2
3
3
6

7
12
13
13

READ AND SAVE THESE INSTRUCTIONS

To reduce the risk of electric shock, ensure electricity has been 
turned off at the circuit breaker or fuse box before beginning.

All wiring must be in accordance with the National Electrical 
Code “ANSI/NFPA 70” and local electrical codes. Electrical 
installation should be performed by a qualified licensed 
electrician.

The outlet box and support structure must be securely mounted 
and capable of reliably supporting a minimum of 35 lb (15.9 kg) 
or less. Use only UL Listed outlet boxes marked “FOR FAN 
SUPPORT.”

The fan must be mounted with a minimum of 7 ft (2.1 m) 
clearance from the trailing edge of the blades to the floor.

Avoid placing objects in the path of the blades.

To avoid personal injury or damage to the fan and other items, 
be cautious when working around or cleaning the fan.

Do not use water or detergents when cleaning the fan or fan 
blades. A dry dust cloth or lightly dampened cloth will be 
suitable for most cleaning.

After making electrical connections, spliced conductors should 
be turned upward and pushed carefully up into the outlet box. 
The wires should be spread apart with the grounded conductor 
and the equipment-grounding conductor on one side of the 
outlet box and ungrounded conductor on the other side of the 
outlet box.

All set screws must be checked and retightened where 
necessary before installation.

1.

2.

3.

4.

5.

6.

7.

8.

9.

WARNING:

 To reduce the risk of electrical shock or fire, do 

not use this fan with any solid-state fan speed control device.  
It will permanently damage the electronic circuitry.

WARNING:

 To reduce the risk of personal injury, do not bend 

the blade arms (also referred to as flanges), when installing 
the brackets, balancing the blades or cleaning the fan.

WARNING:

 Do not insert foreign objects between rotating 

fan blades.

WARNING:

 

To reduce the risk of fire, electric shock or 

personal injury, mount the fan to an outlet box marked 
acceptable for fan support with the screws provided with the 
outlet box.

CAUTION:

 To reduce the risk of personal injury, use only 

the screws provided with the outlet box.

Safety Information

The following responsible party designated in FCC §2.909 is 
responsible for this declaration:
Model Number: AK382HG-BN, AK382HG-MBK, AK382HG-MWH
Company Name: TAL INTERNATIONAL CORPORATION 
Company Address: 2919 E. Philadelphia St., Ontario, CA 91761, U.S.A.
Telephone Number: (909) 923-2888  Fax: (909) 923-8337

NOTE:

 

Suitable for use in damp locations.

Содержание CALTRIS AK382HG-MBK

Страница 1: ...our home improvement needs Thank you for choosing Hampton Bay 1 855 HD HAMPTON HAMPTONBAY COM Questions problems missing parts Before returning to the store 8 a m 7 p m EST Monday Friday 9 a m 6 p m E...

Страница 2: ...be turned upward and pushed carefully up into the outlet box The wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and ungrou...

Страница 3: ...stallation or by affixing any accessories is not covered by this warranty Because of varying climatic conditions this warranty does not cover any changes in brass finish including rusting pitting corr...

Страница 4: ...ware not shown to actual size AA BB CC Plastic wire nut Blade attachment screw with lock washer additional Pull chain and fob Part Description 3 1 2 Quantity HARDWARE INCLUDED Pre Installation continu...

Страница 5: ...H Description Blade support plate Switch housing 20W LED Light kit Glass shade Quantity 5 1 1 1 Part A B C D Quantity 1 1 1 5 Description Mounting plate Canopy ring Fan motor assembly Blade with screw...

Страница 6: ...x The illustrations below show three different ways to mount the outlet box not included To hang your fan where there is an existing fixture but no ceiling joist you may need an installation hanger ba...

Страница 7: ...f the fan motor assembly C Attach the mounting plate A to the outlet box not included with two screws and washers provided with the outlet box Ensure the mounting plate A is tight and secured WARNING...

Страница 8: ...xperience have your fan installed by a licensed electrician Follow the steps below to connect the fan to your household wiring Use the plastic wire nuts AA with your fan Secure the plastic wire nuts A...

Страница 9: ...et Box Green Wire Green or Bare Wire Ground On a dual switch the fan and light can be turned on or off separately Make wire connections as follows using the wire nuts AA Wall switch not included From...

Страница 10: ...rews with lock washers EE Raise up canopy ring B and line up the four tabs FF with the four grooves GG on the fan housing Once lined up slide the canopy ring B up to the fan housing until snug Assembl...

Страница 11: ...switch housing F Place the key holes on the switch housing F over the two screws HH previously loosened from the mounting ring II Turn the switch housing F until the switch housing F locks in place at...

Страница 12: ...or cool weather depend on factors such as the room size ceiling height and numbers of fans The light pull chain controls the light kit ON and OFF PULL CHAIN OPERATING INSTRUCTIONS REVERSE SWITCH OPERA...

Страница 13: ...t on the ceiling Rotate the fan until the next blade is positioned and repeat the measurement using the same point from the ceiling for every blade Measurement deviations should be within 1 8 in If al...

Страница 14: ...pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate...

Отзывы: