Problem

Problem

Solution

Solution

The fan wobbles.

   Verify that all blades and blade bracket screws are secure (most fan wobble problems are caused by 

loose parts). Once the fan is properly installed, run the ceiling fan for 10 minutes to let the fan 
self-adjust. 

If wobble occurs after running the fan for 10 minutes, verify blade level using the following process:

-   Select a point on the ceiling above the tip of one of the blades, then select any fan blade and measure 
from the center of the selected blade to the point on the ceiling. Rotate the fan until the next blade is 
positioned and repeat the measurement using the same point from the ceiling for every blade.  
Measurement deviations should be within 1/8 in. 

-   If all deviations are less than 1/8 in. and the fan continues to wobble, please call Customer Service 
(1-855-HD-HAMPTON) to order a complimentary Blade Balancing Kit.

-   If deviation is greater than 1/8 in., please call Customer Service (1-855-HD-HAMPTON) to order 
complimentary replacements of your brackets.

Содержание AM213-BN

Страница 1: ... 44 IN CEILING FAN THANK YOU THANK YOU Item xxxxxxxxxx Model AM213 BN Questions problems missing parts Before returning to the store call Hampton Bay Customer Service 8 a m 6 p m EST Monday Friday 1 855 HD HAMPTON HAMPTONBAY COM ...

Страница 2: ...unting Instruction Installation Assembly Standard Ceiling Mounting Close to Ceiling Mounting Hanging the Fan Attaching the Fan Blades Installing the Light Kit 2 3 4 4 4 4 5 6 7 8 9 9 10 11 14 16 Operation Pull Chain Operating Instructions Reverse Switch Operating Instructions Care and Cleaning Troubleshooting Service Parts 18 18 18 19 19 21 ...

Страница 3: ...nd the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box All setscrews must be checked and retightened where necessary before installation WARNING To reduce the risk of electric shock ensure electricity has been turned off at the circuit breaker or fuse box before beginning WARNING To reduce the risk of electrical shock or fire...

Страница 4: ...ditions this warranty does not cover any changes in brass finish including rusting pitting corroding tarnishing or peeling Brass finishes of this type give their longest useful life when protected from varying weather conditions A certain amount of wobble is normal and should not be considered a defect Servicing performed by unauthorized persons shall render the warranty invalid There is no other ...

Страница 5: ...preassembled Light kit mounting plate screw preassembled Light kit mounting screws preassembled Plastic nut preassembled Glass cap preassembled Decorative nut preassembled Pull chains and fobs not to scale Plastic plug not to scale 40 watt candelabra bulb not to scale Part Part Description Description 3 4 1 1 2 6 8 3 3 1 1 1 2 1 3 Quantity Quantity NOTE Hardware shown to actual size unless noted o...

Страница 6: ...uantity Quantity 1 4 4 1 1 1 Part Part A B C D E F Quantity Quantity 1 1 1 1 1 1 Description Description Mounting bracket preassembled Canopy ring preassembled Canopy Canopy bottom cover preassembled Hanger ball downrod assembly Coupling cover PACKAGE CONTENTS PACKAGE CONTENTS Pre Installation continued 6 A H I B C E F J K L G D ...

Страница 7: ...e standard downrod installation the distance from the ceiling to the bottom of the fan blades will be approximately 12 in The close to ceiling installation reduces the distance from the ceiling to the bottom of the fan blades to approximately 9 in Once you have decided which ceiling installation you will use refer to the corresponding sections and procedures during the assembly period Where necess...

Страница 8: ...hree different ways to mount the outlet box PP not included PP PP QQ PP PP A Installation MOUNTING OPTIONS MOUNTING OPTIONS WARNING To reduce the risk of fire electric shock or personal injury mount the fan to an outlet box marked acceptable for fan support using the screws provided with the outlet box An outlet box commonly used for the support of lighting fixtures may not be acceptable for fan s...

Страница 9: ...hrough the holes in the collar and the hanger ball downrod assembly E Be careful not to jam the clevis pin CC against the wiring inside the hanger ball downrod assembly E Insert the cotter pin DD through the hole near the end of the clevis pin CC until it snaps into the locked position Tighten the two collar setscrews EE on top of the fan motor assembly G firmly WARNING Failure to properly install...

Страница 10: ...exiting from the top of the fan motor assembly G through the canopy ring B Make sure the slot openings of the canopy ring B are on top and then proceed to place the canopy ring B and canopy C over the collar at the top of the fan motor assembly G Align the mounting holes in the bottom of the canopy C with the holes in the top of the fan motor assem bly G and fasten using the three collar mounting ...

Страница 11: ...x or supporting system marked acceptable for fan support and use the mounting screws provided with the outlet box WARNING The tab in the ring must rest in the groove of the hanger ball E Failure to properly seat the tab in the groove could cause damage to the wiring WARNING The hook is only to hold the fan while attaching wiring Failure to hang as instructed may result in the tab breaking causing ...

Страница 12: ...mounting bracket A since the hanger ball downrod assembly E is not used Connect the fan motor white wire to the supply white neutral wire using a plastic wire nut AA Connect the fan motor black wire and the blue wire to the supply black hot wire using a plastic wire nut AA Turn the wire nut connections upward spreading them apart so the green ground will be on one side of the outlet box PP and the...

Страница 13: ...d WARNING Make sure the tab on the mounting bracket A properly sits in the groove in the hanger ball E before attaching the canopy C to the mounting bracket A by turning the canopy housing until it drops into place 7b Close to ceiling mounting Remove the fan from the hook on the mounting bracket A Secure the canopy C to the mounting bracket A with the four screws with lock washers BB Slide the can...

Страница 14: ...e H engages in the spring locking mechanism UU Make sure the spring of the spring locking mechanism UU is upward and the butt of the spring locking mechanism UU is against the edge of the blade NOTE Your fan blades are reversible Select the blade side finish which best accentuates your decor To install the blade to the blade arm Press down the spring locking mechanism UU to release the blade H fro...

Страница 15: ...the blade arms I while installing balancing the blades H or cleaning the fan Do no insert foreign objects between rotating fan blades H Align the holes on the blade arms I to holes on the motor G and secure with the screws with lock washers GG Tighten the screws GG securely HAMPTONBAY COM Please contact 1 855 HD HAMPTON for further assistance G I H GG ...

Страница 16: ... HH previously removed HH J CCC CAUTION Before starting installation disconnect the power by turning off the circuit breaker or removing the fuse at the fuse box Turning power off using the fan switch is not sufficient to prevent electric shock Assembly Installing the Light Kit 12 Attaching the light kit to the light kit mounting plate While holding the light kit K under the fan snap together the ...

Страница 17: ...ight kit K You can keep the light kit K for future use Attach the plastic plug NN to the switch housing EEE Install the switch housing EEE to the light kit mounting plate J with light kit mounting screws II provided KK JJ LL MM L OO MM K CAUTION Before starting installation disconnect the power by turning off the circuit breaker or removing the fuse at the fuse box Turning power off using the fan ...

Страница 18: ...d to the light kit K NOTE Wait for the fan to stop before reversing the direction of the blade rotation REVERSE SWITCH OPERATING INSTRUCTIONS REVERSE SWITCH OPERATING INSTRUCTIONS The reverse switch is located on the surface of the switch housing Slide the switch to the left for warm weather operation Slide the switch to the right for cool weather operation Warm weather Counterclockwise Direction ...

Страница 19: ...rcuit fuses or breakers Check the line wire connections to the fan and switch wire connections in the switch housing Make sure all motor housing screws are snug Make sure the screws that attach the fan blade arm to the motor hub are tight Make sure wire nut connections are not rattling against each other or the interior wall of the switch housing Allow a 24 hour breaking in period Most noises asso...

Страница 20: ...ng above the tip of one of the blades then select any fan blade and measure from the center of the selected blade to the point on the ceiling Rotate the fan until the next blade is positioned and repeat the measurement using the same point from the ceiling for every blade Measurement deviations should be within 1 8 in If all deviations are less than 1 8 in and the fan continues to wobble please ca...

Страница 21: ...t kit mounting screw preassembled Plastic nut preassembled Glass cap preassembled Decorative nut preassembled Pull chains and fob Plastic plug 40 watt candelabra bulb 21 HAMPTONBAY COM Please contact 1 855 HD HAMPTON for further assistance H I AA KK JJ LL MM NN OO BB CC DD FF GG EE II J L HH Part Part A B C D E F G H I J K L Description Description Mounting bracket preassembled Canopy ring preasse...

Страница 22: ...uestions problems missing parts Before returning to the store call Hampton Bay Customer Service 8 a m 6 p m EST Monday Friday 1 855 HD HAMPTON HAMPTONBAY COM Retain this manual for future use XXXXXXXXXXX ...

Отзывы: