background image

Table of Contents  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Safety Information  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Warranty  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pre-installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Assembly  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Care and Cleaning  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Troubleshooting  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2

Table of Contents

2
2
3
3
6

7
13
15
15

READ AND SAVE THESE INSTRUCTIONS

To reduce the risk of electric shock, ensure electricity has been 
turned off at the circuit breaker or fuse box before beginning.

All wiring must be in accordance with the National Electrical 
Code “ANSI/NFPA 70” and local electrical codes. Electrical 
installation should be performed by a qualified licensed 
electrician.

The outlet box and support structure must be securely mounted 
and capable of reliably supporting a minimum of 35 lb (15.9 kg) 
or less. Use only UL Listed outlet boxes marked “FOR FAN 
SUPPORT.”

The fan must be mounted with a minimum of 7 ft (2.1 m) 
clearance from the trailing edge of the blades to the floor.

Avoid placing objects in the path of the blades.

To avoid personal injury or damage to the fan and other items, 
be cautious when working around or cleaning the fan.

Do not use water or detergents when cleaning the fan or fan 
blades. A dry dust cloth or lightly dampened cloth will be 
suitable for most cleaning.

After making electrical connections, spliced conductors should 
be turned upward and pushed carefully up into the outlet box. 
The wires should be spread apart with the grounded conductor 
and the equipment-grounding conductor on one side of the 
outlet box and ungrounded conductor on the other side of the 
outlet box.

All set screws must be checked and retightened where 
necessary before installation.

Suitable for use with solid-state speed control (MR181B-3 only).

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

WARNING:

 To reduce the risk of electric shock, this fan 

must be installed with an isolating wall control/switch.

WARNING:

 To reduce the risk of personal injury, do not bend 

the blade arms (also referred to as flanges), when installing 
the brackets, balancing the blades or cleaning the fan.

WARNING:

 Do not insert foreign objects between rotating 

fan blades.

WARNING:

 

To reduce the risk of fire, electric shock or 

personal injury, mount the fan to an outlet box marked 
acceptable for fan support with the screws provided with the 
outlet box.

CAUTION:

 To reduce the risk of personal injury, use only 

the screws provided with the outlet box.

Safety Information

The following responsible party designated in FCC §2.909 is 
responsible for this declaration:
Model Number: 

AK376-CH, AK376-MBK

Company Name: 

TAL INTERNATIONAL CORPORATION 

Company Address:  2919 E. Philadelphia St., Ontario, CA 91761, U.S.A.
Telephone Number: (909) 923-2888  Fax: (909) 923-8337

Содержание AK376-MBK

Страница 1: ...e for your home improvement needs Thank you for choosing Hampton Bay 1 855 HD HAMPTON HAMPTONBAY COM Questions problems missing parts Before returning to the store 8 a m 7 p m EST Monday Friday 9 a m...

Страница 2: ...spliced conductors should be turned upward and pushed carefully up into the outlet box The wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side o...

Страница 3: ...allation or by affixing any accessories is not covered by this warranty Because of varying climatic conditions this warranty does not cover any changes in brass finish including rusting pitting corrod...

Страница 4: ...to actual size AA BB CC DD Plastic wire nut Blade attachment screw with lock washer additional 23A 12V battery Extension cord Part Description 3 1 1 1 Quantity HARDWARE INCLUDED Pre Installation cont...

Страница 5: ...assembly Receiver Remote control Quantity 5 1 1 1 Part A B C D E F Quantity 1 1 1 1 1 1 Description Mounting bracket preassembled Canopy Canopy bottom cover preassembled Hanger ball downrod assembly...

Страница 6: ...hanger bar not included as shown above Outlet Box Outlet Box Hanger Bar Outlet Box Recessed Outlet Box A WARNING To reduce the risk of fire electric shock or personal injury mount the fan to an outle...

Страница 7: ...take out the screw located in the hanger ball lower the hanger ball and remove the pin Remove all three pieces from the downrod and assemble them onto the new longer downrod before proceeding to the...

Страница 8: ...provided with the outlet box Note that the flat side of the mounting bracket A is toward the outlet box Securely tighten the two mounting screws WARNING The tab in the ring must rest in the groove of...

Страница 9: ...over on the remote control K NOTE The frequencies on your receiver and remote control have been preset at the factory Before installing the receiver make sure the dip switches on the receiver and remo...

Страница 10: ...connections WARNING To reduce the risk of electric shock this fan must be installed with an isolating wall control switch Insert the receiver J into the mounting bracket A with the flat side of the r...

Страница 11: ...on the mounting bracket A Turn the canopy B clockwise until it locks in place at the narrow section of the key holes Make sure the positioning pin JJ on the mounting bracket falls into one of two hol...

Страница 12: ...e 16W LED light kit assembly I so they line up with the tabs QQ on the inside of the rim on the light kit mounting plate NN Secure it to the fan by turning the 16W LED light kit assembly I clockwise u...

Страница 13: ...to the corresponding speed Press and release 1 time turns the fan on high speed Press and release 2 times turns the fan on medium speed Press and release 3 times turns the fan on low speed Press and...

Страница 14: ...t for the fan to stop before reversing the direction of the blade rotation Warm weather Counterclockwise Direction A downward air flow creates a cooling effect This allows you to set your air conditio...

Страница 15: ...er are set to the same frequency Make sure all motor housing screws are snug Make sure the screws that attach the fan blade to the motor hub are tight Make sure the wire nut connections are not rattli...

Страница 16: ...pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate...

Отзывы: