background image

7.

BLUE

BLACK

WHITE

GREEN

BLUE

BLACK

WHITE

WHITE

Outlet 

Box

SUPPLY CIRCUIT

Green

Grounding

Lead

BLACK

WHITE

Ground 

to 

Downrod

Making the Electrical 

Connections

REMEMBER

  to  disconnect  the  power.  If 

you  feel  you  do  not  have  enough  electrical 

wiring knowledge or experience, have your fan 

installed by a licensed electrician. 

Follow  the  steps  below  to  connect  the  fan 

to  your  household  wiring.  Use  the  wire 

connecting  nuts  supplied  with  your  fan.  Se-

cure  the  connectors  with  electrical  tape. 

Make  sure  there  are  no  loose  strands  or 

connections.

Connect the ground conductor of the 120v 

1. 

supply (this may be a bare wire or a wire 

with green insulation) to the green ground 

lead(s) of the fan (Figure 12). When using 

standard  ceiling  mounting,  there  are  two 

green grounding leads; one from the ceiling 

mounting plate and one from the ball/down-

rod assembly. When using Close-to-Ceiling 

mounting,  there  is  only  one  green  ground 

lead from the mounting plate since the ball/

downrod assembly is not used.

Connect  the  fan  motor  white  wire  to  the 

2. 

supply white (neutral) wire using a wire nut 

(Figure 12).

ELECTRICAL  DIAGRAMS  ARE  FOR  REFER-

ENCE ONLY. OPTIONAL USE OF ANY LIGHT KIT 

SHALL BE UL LISTED AND MARKED SUITABLE 

FOR USE WITH THIS FAN.

CHECK TO SEE THAT ALL CONNECTIONS ARE 

TIGHT,  INCLUDING  GROUND,  AND  THAT  NO 

BARE WIRE IS VISIBLE AT THE WIRE NUTS, EX-

CEPT FOR THE GROUND WIRE.

TO  REDUCE  RISK  OF  FIRE  OR  ELECTRIC 

SHOCK, DO NOT USE A WALL MOUNTED SOLID 

STATE  SPEED  CONTROL  WITH  THIS  FAN.  IT 

WILL PERMANENTLY DAMAGE THE ELECTRON-

IC CIRCUITRY.

Figure 12

Connect the fan motor black wire to the sup-

3. 

ply black (hot) wire using a wire nut (Figure 

12).

After  connecting  the  wires,  spread  them 

4. 

apart so that the green and white wires are 

on one side of the outlet box and the black 

wire is on the other side.

Turn the wire connecting nuts upward and 

5. 

push into the outlet box.

Содержание 52" Huntington III

Страница 1: ......

Страница 2: ...www homedepot com Please reference your SKU 519 694 oil rubbed bronze or UPC 82392 810528 oil rubbed bronze Thank you for purchasing this Hampton Bay ceiling fan This product has been manufactured with the highest standards of safety and quality The finish of this fan is weather resistant but over time will naturally weather and fade Safety Rules 1 Unpacking Your Fan 2 Installing Your Fan 3 Operat...

Страница 3: ...dust cloth or lightly dampened cloth will be suitable for most cleaning After making electrical connections spliced conductors 11 should be turned upward and pushed carefully up into outlet box The wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box Electrical diagrams are for reference only Light kits that are 12 not packed ...

Страница 4: ... Extra Switch Cup 7 Fan Motor Assembly with Pre Attached 1 Blade Brackets and Light Fixture Canopy with Slide On Ceiling 2 Mounting Plate Blades 5 3 2 Unpacking Your Fan IMPORTANT THIS PRODUCT AND OR COMPONENTS ARE COVERED BY ONE OR MORE OF THE FOLLOWING U S PATENTS 5 947 436 5 988 580 5 971 573 6 010 306 6 039 541 6 046 416 AND OTHER PATENTS PENDING Unpack your fan and check the contents You shou...

Страница 5: ...ger downrod to maintain proper blade clearance when install ing on a steep sloped ceiling The maximum angle allowable is 30 If the canopy touches downrod remove the decorative canopy bottom cover and turn the canopy 180 before attaching the canopy to the mounting plate Outlet Box To hang your fan where there is an existing fixture but no ceiling joist you may need an installation hanger bar as sho...

Страница 6: ...allation reduces the distance from the ceiling to the bottom of the fan blades to approximately 8 inches Once you have decided which ceiling installation you will use proceed with the following instructions Where necessary Turn Canopy Ring to Remove Figure 5 Remove Loosen but Do Not Remove Figure 6 Figure 7 Remove the mounting plate from the canopy 3 by loosening the four screws on the top of the ...

Страница 7: ...anopy by 1 turning the ring to the right until it unlocks Figure 5 Remove the mounting plate from the canopy 2 by loosening the four screws on the top of the canopy Remove the two non slotted screws and loosen the slotted screws This will enable you to remove the mounting plate Figure 6 Remove the decorative canopy bottom cov 3 er from the canopy by depressing the three studs Figure 8 Figure 8 Can...

Страница 8: ...ting hang the fan on the hook provided by utilizing one of the holes at the outer rim of the ceiling canopy Fig ure 11 If using standard mounting seat the hanger ball in the mounting plate socket Make sure the tab on the mount ing plate socket is properly seated in the groove in the hanger ball Figure 11 THE HOOK AS SHOWN IN FIGURE 11 IS ONLY TO BALANCE FAN WHILE ATTACHING WIRING FAILURE TO HANG A...

Страница 9: ...all down rod assembly When using Close to Ceiling mounting there is only one green ground lead from the mounting plate since the ball downrod assembly is not used Connect the fan motor white wire to the 2 supply white neutral wire using a wire nut Figure 12 ELECTRICAL DIAGRAMS ARE FOR REFER ENCE ONLY OPTIONAL USE OF ANY LIGHT KIT SHALL BE UL LISTED AND MARKED SUITABLE FOR USE WITH THIS FAN CHECK T...

Страница 10: ... 4 blades WHEN USING THE STANDARD BALL DOWNROD MOUNTING THE TAB IN THE RING AT THE BOT TOM OF THE MOUNTING PLATE MUST REST IN THE GROOVE OF THE HANGER BALL FAILURE TO PROPERLY SEAT THE TAB IN THE GROOVE COULD CAUSE DAMAGE TO WIRING LOCKING SLOTS OF CEILING CANOPY ARE PROVIDED ONLY AS AN AID TO MOUNTING DO NOT LEAVE FAN ASSEMBLY UNATTENDED UNTIL ALL FOUR CANOPY SCREWS ARE EN GAGED AND FIRMLY TIGHTE...

Страница 11: ... the power off insert the light bulbs 3 MAX 14 watts provided into the light kit sockets Squeeze steel tensioners together Silde shades over steel tensioners Figure 14 Mechanism Engage Locking Motor Assembly and Pull Blade Away from Blade Balancing All blades are grouped by weight Because nat ural woods vary in density the fan may wobble even though the blades are weight matched The following proc...

Страница 12: ... Remove the three screws that secure the fix 1 ture to the bottom of the switch cup Carefully pull down the light kit and discon 2 nect the two plugs that connect the light kit to the fan Tuck the wires from the fan into the switch cup Figure 15a Align the holes in the switch cup cover with 3 the holes in the switch cup and push into place Secure the switch cup cover with the three 4 screws remove...

Страница 13: ...own or reverse switch up Figure 16 Figure 17 WAIT FOR THE FAN TO STOP BEFORE REVERS ING THE DIRECTION OF BLADE ROTATION Warm weather Forward A downward air flow creates a cooling effect as shown in Figure 16 This allows you to set your air conditioner on a higher setting without affecting your comfort Cool weather Reverse An upward air flow moves warm air off the ceiling are as shown in Figure 17 ...

Страница 14: ...ngs MAKE SURE THE POWER IS OFF AT THE ELECTRICAL PANEL BOX BE FORE YOU ATTEMPT TO MAKE ANY REPAIRS REFER TO THE SECTION MAKING ELECTRICAL CONNECTIONS Fan will not start Fan sounds noisy Troubleshooting Problem Solution Check main and branch circuit fuses or breakers 1 CAUTION Make sure main power is off 2 Check line wire connec tions to the fan and switch wire connections in the switch housing Mak...

Страница 15: ...52 Low 120 0 22 9 69 1595 22 4 Lbs 24 8 Lbs 2 3 Med 120 0 36 26 117 3727 High 120 0 54 65 178 5513 These are approximate measures They do not include Amps and Wattage used by the light kit Distributed by Your Other Warehouse LLC 12100 Little Cayman Dr Baton Rouge LA 70809 Vendor number 219030 ...

Страница 16: ...be considered a defect Servicing performed by un authorized persons shall render the warranty invalid There is no other express warranty Hampton Bay hereby disclaims any and all warranties including but not limited to those of merchantability and fitness for a particular purpose to the extent permitted by law The duration of any implied war ranty which cannot be disclaimed is limited to the time p...