background image

Part

Part

G

H

I

J

K

Description

Description

Fan motor assembly

Blade

Blade arm

Light kit mounting plate

Switch housing

Quantity

Quantity

1

5

5

1

1

 

Part

Part

A

B

C

D

E

F

Quantity

Quantity

1

1

1

1

1

1

Description

Description

Mounting bracket (preassembled)

Canopy ring (preassembled)

Canopy

Canopy bottom cover (preassembled)

Hanger ball/downrod assembly

Coupling cover

PACKAGE CONTENTS

PACKAGE CONTENTS

Pre-Installation (continued)

6

H

I

A

E

F

J

K

G

B
C
D

Содержание 1002270078

Страница 1: ...NG FAN THANK YOU THANK YOU Item 1002270078 Model YG593 TB 1 855 HD HAMPTON HAMPTONBAY COM Questions problems missing parts Before returning to the store 8 a m 7 p m EST Monday Friday 9 a m 6 p m EST Saturday call Hampton Bay Customer Service ...

Страница 2: ...nting Instructions Installation Assembly Standard Ceiling Mounting Close to Ceiling Mounting Hanging the Fan Attaching the Fan Blades 2 3 4 4 4 4 5 6 7 8 9 9 10 11 14 16 Operation Pull Chain Operating Instructions Reverse Switch Operating Instructions Care and Cleaning Troubleshooting Service Parts 17 17 17 18 18 20 Installing the Light Kit ...

Страница 3: ... After making electrical connections spliced conductors should be turned upward and pushed carefully up into the outlet box The wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box 9 All setscrews must be checked and retightened where necessary before installation WA...

Страница 4: ...ngest useful life when protected from varying weather conditions A certain amount of wobble is normal and should not be considered a defect Servicing performed by unauthorized persons shall render the warranty invalid There is no other express warranty We hereby disclaim any and all warranties including but not limited to those of merchantability and fitness for a particular purpose to the extent ...

Страница 5: ... with lock washer preassembled Blade arm screw with lock washer preassembled Light kit mounting plate screw preassembled Switch housing mounting screw preassembled Pull chain and fob not to scale Plastic plug not to scale Part Part Description Description 3 4 1 1 2 6 10 3 4 1 1 Quantity Quantity NOTE Hardware shown to actual size unless noted otherwise in the table below AA BB CC DD JJ KK HH II EE...

Страница 6: ...ntity Quantity 1 5 5 1 1 Part Part A B C D E F Quantity Quantity 1 1 1 1 1 1 Description Description Mounting bracket preassembled Canopy ring preassembled Canopy Canopy bottom cover preassembled Hanger ball downrod assembly Coupling cover PACKAGE CONTENTS PACKAGE CONTENTS Pre Installation continued 6 H I A E F J K G B C D ...

Страница 7: ...e standard downrod installation the distance from the ceiling to the bottom of the fan blades will be approximately 12 in The close to ceiling installation reduces the distance from the ceiling to the bottom of the fan blades to approximately 9 in Once you have decided which ceiling installation you will use refer to the corresponding sections and procedures during the assembly period Where necess...

Страница 8: ...hree different ways to mount the outlet box LL not included LL LL MM LL LL A Installation MOUNTING OPTIONS MOUNTING OPTIONS WARNING To reduce the risk of fire electric shock or personal injury mount the fan to an outlet box marked acceptable for fan support using the screws provided with the outlet box An outlet box commonly used for the support of lighting fixtures may not be acceptable for fan s...

Страница 9: ... then through the hanger ball downrod assembly E Align the holes at the bottom of the hanger ball downrod assembly E with the holes in the collar on top of the fan motor assembly G Carefully insert the clevis pin CC through the holes in the collar and the hanger ball downrod assembly E Be careful not to jam the clevis pin CC against the wiring inside the hanger ball downrod assembly E Insert the c...

Страница 10: ...opy ring B and canopy C over the collar at the top of the fan motor assembly G Align the mounting holes in the bottom of the canopy C with the holes in the top of the fan motor assem bly G Fasten using the three collar mounting screws with lock washers FF previously removed Tighten the collar mounting screws FF securely A BB BB C B Remove the canopy ring B from the canopy C Remove the mounting bra...

Страница 11: ...c shock or other personal injury mount the fan only to an outlet box or supporting system marked acceptable for fan support and use the mounting screws provided with the outlet box WARNING The tab in the ring must rest in the groove of the hanger ball E Failure to properly seat the tab in the groove could cause damage to the wiring WARNING The hook is only to hold the fan while attaching wiring Fa...

Страница 12: ...to your household wiring Use the plastic wire nuts AA with your fan Secure the plastic wire nuts AA with electrical tape Make sure there are no loose strands or connections Connect the ground conductor of the 120V supply this may be a bare wire or a wire with green colored insulation to the green ground lead s of the fan There are two green grounding leads one from the mounting bracket A and one f...

Страница 13: ...ew with lock washer BB included with your fan Slide the canopy ring B over the canopy C and tighten by turning the ring B Remove the fan from the hook on the mounting bracket A Secure the canopy C to the mounting bracket A with the four canopy mounting screw with lock washer BB provided Slide the canopy ring B over the canopy C and tighten by turning the ring B WARNING The locking slots of the can...

Страница 14: ...e blade H engages in the spring locking mechanism QQ Make sure the spring of the spring locking mechanism QQ is upward and the butt of the spring locking mechanism QQ is against the edge of the blade NOTE Your fan blades are reversible Select the blade side finish which best accentuates your decor To install the blade to the blade arm Press down the spring locking mechanism QQ to release the blade...

Страница 15: ...an Do not insert foreign objects between rotating fan blades H Fasten the blade assemblies to the fan motor assembly G by lining up the slots RR of the motor with the tabs on the blade arms SS Tighten the two blade arm screws with lock washers GG already installed in the blade arms I Repeat this procedure for the remaining blade arms I G RR I H GG SS 15 HAMPTONBAY COM Please contact 1 855 HD HAMPT...

Страница 16: ...g plate screws HH previously loosened and the one HH previously removed HH J TT CAUTION Before starting installation disconnect the power by turning off the circuit breaker or removing the fuse at the fuse box Turning power off using the fan switch is not sufficient to prevent electric shock Assembly Installing the Light Kit 12 Attaching the switch housing to the light kit mounting plate While hol...

Страница 17: ...e blade rotation REVERSE SWITCH OPERATING INSTRUCTIONS REVERSE SWITCH OPERATING INSTRUCTIONS The reverse switch is located on the surface of the switch housing Slide the switch to the left for warm weather operation Slide the switch to the right for cool weather operation Warm weather Counterclockwise Direction A downward air flow creates a cooling effect This allows you to set your air conditione...

Страница 18: ...e power is off at the electrical panel box before you attempt any repairs Refer to step 6 Making the Electrical Connections on page 12 Problem Problem Solution Solution Check the main and branch circuit fuses or breakers Check the line wire connections to the fan and switch wire connections in the switch housing Make sure all motor housing screws are snug Make sure the screws that attach the fan b...

Страница 19: ...then select any fan blade and measure from the center of the selected blade to the point on the ceiling Rotate the fan until the next blade is positioned and repeat the measurement using the same point from the ceiling for every blade Measurement deviations should be within 1 8 in If all deviations are less than 1 8 in and the fan continues to wobble please call Customer Service 1 855 HD HAMPTON t...

Страница 20: ...art Part AA BB CC DD EE FF GG HH II JJ KK Description Description Plastic wire nut Canopy mounting screw with lock washer preassembled Clevis pin preassembled Cotter pin preassembled Collar setscrew preassembled Collar mounting screw with lock washer preassembled Blade arm screw with lock washer preassembled Light kit mounting plate screw preassembled Switch housing mounting screw preassembled Pul...

Страница 21: ...ON HAMPTONBAY COM Retain this manual for future use YG593TB001 A Questions problems missing parts Before returning to the store 8 a m 7 p m EST Monday Friday 9 a m 6 p m EST Saturday call Hampton Bay Customer Service ...

Отзывы: