FOUR STACK II
Setup and Operation Instructions
Four Stack II Control Box
Four Stack II Switch Box
The
Four Stack II
was designed to operate any array of one to four antennas within the same band.
It is also possible to operate with two different antenna arrangements, one for reception and one for
transmission.
When the station has more than one
Four Stack II
, such as one for 10m and another for 15m, a
maximum of four, it is possible to operate in a network. Network operation allows any of the
Four Stack
II
commands to operate the Switch from another
Four Stack II
.
1-
Individual operation
In this mode each control box controls only the relay box in which it is connected. The choice of
antennas is made by pressing the push button corresponding to the desired antennas. One touch
connects and another touch disconnects. The illuminated push button indicates that the antena
is connected.
To use an arrangement of antennas in transmission different from the arrangement used in
reception proceed as follows:
Press and hold the
ENTER
push button and choose the desired antennas by pressing the
corresponding push button. The chosen antennas will be signaled by the red LEDs located above
each push button.
The switching of the reception arrangement to the transmission arrangement will take place
when the
PTT
of the Radio is activated
2-
Network operation
Network operation is only applied when two to four
Four Stack II
sets are used. The purpose of
the network operation is to allow the control of a
Four Stack II
to operate the switch box of an
other
Four Stack II
.
a-
First step
- Place addresses in each of the
Four Stack II.
Proceed as follows:
Press the
ENTER
push button for about ten seconds until all the push buttons blink a few
times. The
ENTER
push button will continue flashing. Then choose the address by pressing one
of the four push buttons,
Ant1
,
Ant2
,
Ant3
, or
Ant.4
.
The address chosen for the
Four Stack II
will be shown by the red Led in the
Band
column.
Repeat this procedure for all
Four Stack II
by placing different addresses in each of them