HAMMAR ERRS CP2 

ELECTRONIC REMOTE 

RELEASE SYSTEM

 

ERRS CP2 INSTALLATION AND TEST MANUAL 

ISSUED 2019-02 

Rev.4 

 

Installation information 

The first power up of the system after installation (i.e. installing main fuse, connecting battery and 

connecting the main connector to the back of the ERRS front panel) shall only be done by trained 

personal familiar with the technical function and use of the ERRS system. 

 

Note! After the battery has been connected to the system it will automatically take over the power 

supply to the ERRS CP2 system if the ships emergency power supply is switched off or interrupted. 

The battery will lose capacity by repeated deep discharging cycles. It is important that the battery 

is disconnected in situations where an interrupted emergency power supply can be expected, as 

for an example during a stay at a shipyard. Note that there is a backup battery in each ERRS CP2 

Control Panel if more than one panel is connected in a network. 

 

 

 

Содержание ERRS CP2

Страница 1: ...and use of the ERRS system Note After the battery has been connected to the system it will automatically take over the power supply to the ERRS CP2 system if the ships emergency power supply is switc...

Страница 2: ...rder to avoid water or dirt to get inside the box When the installation is finished all holes in the ERRS CP2 enclosure shall have EMC cable glands or sealing plugs installed There shall be no opening...

Страница 3: ...tion so that it is ensured that the connection cable of the H20 ERU can be connected Mount the connector box with the cable glands in a horizontal position and in a protected position with respect to...

Страница 4: ...ERRS CP2 enclosure Only use the original type of cable glands Additional cable glands can be ordered from CM HAMMAR AB The Enclosure shall be connected to ships ground by the Ground connection device...

Страница 5: ...imum current consumption for the system is 0 5 A Internal fuses S1 1 0AF 5x20 mm glass tube fuse See wiring diagram for maximum cable length and area H20 ERU Cut the flexible cable of the H20 ERU to a...

Страница 6: ...ep 7 and 8 for all outputs to ensure that all outputs are connected to the right release unit 10 When all outputs have been checked push the MAINTENANCE pushbutton to exit the maintenance menu Activat...

Страница 7: ...inputs activates the correct outputs or sequence of outputs Testing activation by the use of fuses Connect a fuse between the terminals in ERU connection box for the output to be tested Connect jumpe...