background image

Hardy 4 - Series 4 

 

1 - 4 

  458  18    330 

13 

  323  12

3/4 

  370  14

12 

  93.5  3

3/4 

 

  102 

 

 

 

 

AIB7 

 

2.8 

 

1.2 

Hardy 5 - Series 4 

 

1 - 5 

  475  19    370  14

1/2 

  333 

13 

  387  15

1/4 

  93.5  3

1/4 

 

  102 

 

 

 

 

AIB0 

 

3.2 

 

1.8 

Camborne Deluxe Compact 
Generation 2 

 

1 - 5 

  505  20    394  15

1/2 

  377  14

3/4 

  409 

16 

  103 

 

  102 

 

 

 

 

AIB0 

 

3.2 

 

1.8 

Camborne Deluxe Small  
Generation 2 

 

1 - 5 

  530  20

3/4 

  477  18

3/4 

  386 

15 

  423  16

3/4 

  103 

 

  127 

 

 

 

 

AIB8 

 

 

Camborne Deluxe Medium 
Generation 2 

 

2 - 8 

  552  21

3/4 

  586 

23 

  382 

15 

  423  16

3/4 

  105  4

1/4 

 

  127 

 

 

 

 

AIB9 

 

5.4 

 

2.6 

Camborne Deluxe Large 
Generation 2 

 

2.5 - 11    552  21

3/4 

  572  26

1/2 

  467  18

1/2 

  434 

17 

  141  5

1/2 

 

  152 

 

 

 

 

AIB10 

 

7.6 

 

3.4 

Solution 5  - Series 2 

 

1 - 5 

  522  20

1/2 

  397  15

1/2 

  388  15

1/4 

  424  16

3/4 

  94 

3

3/4 

 

625  525    102 

 

74.7% 

 

306 

 

0.58 

 

AIB0 

 

3.2 

 

1.8 

Solution 7 - Series 2 

 

1.5 - 6    558  22    476  18

3/4 

  386 

15 

  449  17

1/2 

  109  4

1/2 

 

650  450    127 

 

72.1% 

 

363 

 

0.58 

 

AIB8 

 

 

Solution 9 - Series 2 

 

2 - 9 

  600  23

1/2 

  586 

23 

  396  15

1/2 

  485 

19 

  103 

 

750  500    127 

 

71.6% 

 

364 

 

0.68 

 

AIB9 

 

6.4 

 

2.6 

Solution 11 - Series 2 

  2.5 - 11    605  23

3/4 

  672  26

1/2 

  442  17

1/2 

  479  18

3/4 

  141  5

1/2 

 

800  500    152 

 

74.7% 

 

670 

 

0.71 

 

AIB10 

 

7.6 

 

3.4 

Technical Specifications 

Output 

kW 

Description 

Depth 

mm   inches 

Height 

mm   inches 

Width 

mm   inches 

Depth from 

back to 

centre of 

top flue 

mm   inches 

Height to 
centre of 

rear flue 

mm   inches 

Solution 5 Inset  

 

1 - 5 

  590  23

1/4 

  572  22

1/2 

  404 

16 

  225 

9”    155 

6” 

 

Rectangular 

Letter Box 

  80.1%   

261 

 

0.50 

 

Solution 7 Inset 

 

1.5 - 7 

  590  23

1/4 

  572  22

1/2 

  555 

22 

  362  14

1/4 

  127 

5” 

 

30” Sloping 

Flue 

  72.1%   

346 

 

0.58 

 

Output 

kW 

Description 

Depth 

mm   inches 

Height 

mm   inches 

Width 

mm   inches 

Depth of 

front fascia 

mm   inches 

Depth 

into  

fireplace 

mm   inches 

Inset Models 

Freestanding  

Содержание BK540

Страница 1: ...BK540 EN 13240 2001 Amd A2 February 2013 PLEASE RETAIN THIS GUIDE FOR FUTURE REFERENCE User Guide For stove ranges Camborne Deluxe Generation 2 Hardy 4 5 Series 4 Solution Series 2...

Страница 2: ...ances including multi fuel stoves If in doubt contact The Solid Fuel Association telephone 0845 601 4406 01773 835400 or visit www solidfuel co uk It is a legal requirement that the installation of al...

Страница 3: ...a chimney fire Please Note If you have sticky tar inside the appliance or chimney your wood is green or too wet PAPER Paper will burn successfully Burn dry paper only or chimney damage will occur WARN...

Страница 4: ...ating the air controls Your stove has two air inlet controls These may be located either on the stove body or the door The primary air inlet providing under draught to the base of the fire chamber and...

Страница 5: ...e off fumes which are non toxic but certain persons may find they have an unpleasant or irritant effect Ensure that the surrounding area is well ventilated during this time BURNING SOLID FUELS Only ap...

Страница 6: ...any damaged bars replaced Also check for obstructions that may prevent the operation of the riddling mechanism DOOR GLASS The door glass should remain clear during normal burning However under certai...

Страница 7: ...d up to touch the underside of the grate bars as this will greatly reduce the life span of the grate The ash will require less frequent removal when burning wood compared to solid fuels WARNING The as...

Страница 8: ...he fire door can be re aligned as follows 1 When the appliance is cold open the fire door so that it is at right angles to the front of the stove 2 Lift the fire door up off its hinges 3 Gently tap th...

Страница 9: ...oduced in the event of a claim being made Claims are not valid where installation does not conform to appropriate building regulations The manufacturers decision shall be final However if your applian...

Страница 10: ...151 4 424 163 4 94 33 4 6 Solution 7 Series 2 1 5 6 558 22 476 183 4 386 15 449 171 2 109 41 2 6 Solution 9 Series 2 2 9 600 231 2 586 23 396 151 2 485 19 103 4 7 Solution 11 Series 2 2 5 11 605 233 4...

Страница 11: ...364 0 68 AIB9 6 4 2 6 51 2 800 500 152 6 74 7 670 0 71 AIB10 7 6 3 4 Flue Diameter mm inches Nett Efficiency Mean Flue Gas Temperature Mean CO Emissions 13 O2 Add in Boiler If Available 6 Rectangular...

Страница 12: ...Plate Door Catch Door Handle Operating Tool Stove Glove Grate Fuel Bed Installation Guide Assembled By Checked by Model The Fireworks Weycroft Avenue Axminster Devon EX13 5HU www arada uk com www arad...

Отзывы: