6
Step#17
Install foam strip to strike edge of tube opening
Step#18
Test door operation. Door should stay sealed tight
so that door seal closes against it.
when carrier arrives in teller. If the door seal leaks
on the strike side, you can adjust the position of the
Detent Mounting Block to the right.
C
L
O
S
E
39
5
4
K
Step#19
Adjusting Spring Plunger. 3-Ways to do so.
Step#20
Re-install Upper and Lower Switch covers.
1)
Adjust plunger depth (In-Out)
Note: Use 10-32 x ¼ HHMS provided in kit
2)
Adjust mounting block location (Left-Right)
to mount lower switch cover.
3)
Adjust plunger spring tension (Rear Set Screw)
Note:
Grease the Pin end of Plunger and the steel
roller pressed in the aluminum Door Ring with
grease supplied in kit.