HTX30 Product Manual
Fault Finding
6-9
SCP alarms
Name
SCP text
Description
Priority
Control conflict CTRL / CNFLT
More than one SCP is in control
Warning
Simulate mode SIMUL
The SCP is simulating control and feedback
Warning
In backup
BAKUP
This module is in backup mode
Alarm
In setup
SETUP
This module is running setup
Subcodes:
0 - From SCP
1 - From other
Warning
Warmup
WRMUP
The engine is in warm up mode and the operator has requested
too much throttle
Warning
Gearbox
followup
GBXFO
The gearbox has not followed up on the operator demand or the
gear has unexpectedly changed
Warning
Backup
disagrees
BAKUP / DISAG Some modules are in backup mode and some are in normal. The
subcode is a bitmask of the modules that claim to be in normal.
Comparing this with what is actually in the system should show
which module disagrees. The lower four bits are the EIMs, the 4 to
7th are the JIMs, and the 8th to 15th are the SCPs. Note that
everything is one based
Warning
Bad CIDs
INVAL / CTRLS
This module has no CIDs or has a invalid set of CIDs
Subcodes:
0 - OK: No error. The connected CIDs are fine
1 - Unknown: There is an unknown problem with the CID
configuration. This subcode shouldn't happen
2 - Overlap: The demands supplied by the attached CIDs
overlap. For example, more than one module may be
providing throttle demand
3 - No Space: There are more CIDs attached than the system
can manage
4 - No CIDs: No CIDs are attached
5 - Insufficient Sources: The attached CIDs do not provide
control of either steering, reverse, or throttle
6 - Expected no CIDs: The SCP is configured to be 'naked' and
expects to have no CIDs attached
7 - Incompatible CIDs: One or more of the attached CIDs are
incompatible with the system configuration. An example is a
Mouseboat on a single jet system
Alarm
Too many
autopilots
EXTRA / AUTOP More than one station is set to have an autopilot
Warning
Autopilot in
control
AUTOP
Autopilot is in control
Warning
System not
registered
REGST
The system has not been registered or the registration is invalid
Warning
Hardware fault HWFLT
A hardware fault has occurred in this SCP.
Subcodes:
0 - Unknown
1 - Data Flash
2 - Param Flash
3 - UART
Alarm
Содержание HTX30
Страница 1: ...HTX30 HTX30 Product Manual R0A5 blue ARROW...
Страница 8: ...1 vi...
Страница 20: ......
Страница 26: ......
Страница 31: ...HTX30 Product Manual Component Installation 4 5 Module connections Figure 6 Single jet interconnecting cabling...
Страница 133: ...HTX30 Product Manual Appendix 8 19 Figure 22 Station control panel dimensions Station control panel module weight 2 0 kg...
Страница 134: ...Appendix HTX30 Product Manual 8 20 Figure 23 Dual single lever module dimensions Dual single lever module weight 2 8 kg...
Страница 178: ......
Страница 181: ...Notes...