Page 30 of 92
520008300 08/14
SmartServe™ Drink Mixers Service Manual
Removal and Replacement
Operator Interface Panel Assembly
The operator interface panel assembly is located on the front of the machine and is used
to operate the machine. The assembly has a breaker switch, control board, touch pad, and
access door that are serviceable.
WARNING
To avoid risk of serious injury or death, disconnect power to the machine before
cleaning, servicing, or removing parts.
CAUTION
Do not use power tools to remove hardware. Damage to the hardware or the machine
may occur. Do not lose hardware.
To remove the operator interface panel assembly:
1. Ensure the control panel power switch (1) is in the OFF position and unplug the
machine.
2. Lift the metal tab (2) on the panel to lower the access door (3).
1
2
3
Содержание SmartServe MIC2000