OPERATION

Ambient temperature

Temperature 0-35°C

Atmosphere 86-106 kpa

VOLTAGE:115V/60HZ

Position the water cooler on the horizontal, structurally sound ground. Leave an

adequate open space (10-20 cm) behind the water cooler for good ventilation.

When using the bottles holding ultra-pure water, distilled water or space water with

the so-called clever lid, tear off the hygienic labels on the lid. Place the bottles at the

intake, then the core of water guard will automatically open the valve and seal it in

the meantime, when moving the bottles, the valve will also seal automatically to

avoid any possible oozing.

Push the hot water valves, bubbles are generated inside the bottle, indicating that

water is flowing into hot water and cold water tanks, keep pressing the hot water

valve until water flows out, dispensing cold water required need no particular

adjustment.

Caution: Do not connect the electrical power plug until water comes out of the hot

water tap.

After water is flowing out from the hot tap, then we can open the switch at the back

side.

Turn the heating switch on, the red indicator is on and the heating system starts

working. When the hot water comes up (86-95°C) or so, the red light goes off, the

heating system stops working, and it is on a warm keeping status.

When the hot water temperature is lower than 85°C, the heating system will resume

working again automatically.

Turn on the cooling switch, the green indicator is on and the cooling system starts

working. When the cold water falls down to 5-10°C (for compressor-cooling), the

green light goes off, the cooling system stops working, and it is on a cold keeping

status.
When the cold water temperature goes up to a set degree, the cooling system will

resume working again atomically.

Since the temperature has already been adjusted before leaving the factory, it is

unnecessary for customers to set the temperature.

If device is not applied for a long time, after the hot water cools down, please

remove the power plug and revolve the drain the rest water in the hot tank then

tighten the cap open the cold water tap to drain the rest water in the cold tank.

If there is no water flowing from cooling tap, please shut down the cooling switch until

there is water flowing out.

Содержание HBWC112-SSWH

Страница 1: ...Y RULES AND OPERATING INSTRUCTIONS Hamilton Beach is a registered trademark of Hamilton Beach Brands Inc used under license by Curtis International Ltd For service assistance and product information please call 1 800 968 9853 Curtis International Ltd 7045 BECKETT DRIVE UNIT 15 MISSISSAUGA ON L5S 2A3 www curtisint com ...

Страница 2: ...always ...

Страница 3: ...NAME AND STRUCTURE 1 Power ON OFF switches at rear 2 Water Bottle Inlet 3 Hot Water Button 4 Cold Water Button 5 Indicator Lights 6 Hot Water Faucet 7 Cold Water Faucet 8 Water Drip Tray ...

Страница 4: ...open the switch at the back side Turn the heating switch on the red indicator is on and the heating system starts working When the hot water comes up 86 95 C or so the red light goes off the heating system stops working and it is on a warm keeping status When the hot water temperature is lower than 85 C the heating system will resume working again automatically Turn on the cooling switch the green...

Страница 5: ...similarly qualified persons in order to avoid a hazard WARNING Do not damage the refrigerant circuit WARNING Do not use electrical appliances inside the food storage compartments of appliance unless they are of the type recommended by the manufacturer MAINTENANCE Remove power plugs or disconnect from the mains before performing any maintenance or servicing the product Never use detergent or chemic...

Страница 6: ...l The water cooler does not have the correct clearance Vibration Check to assure that the water cooler is level The water cooler seems to make to much noise The rating noise may come from flow of the refrigerant which is normal As each cycles ends you may hear gurgling Sound cause by the flow of refrigerant in your water cooler Contraction and expansion of inside walls may cause popping and cracki...

Страница 7: ...consumer purchaser or gift recipient Keep the original sales receipt as proof of purchase is required to make a warranty claim This warranty is void if the product is used for other than single family household use or subjected to any voltage and waveform other than as on the specified rating on the label e g 120V 60Hz We exclude all claims for special incidental and consequential damages caused b...

Страница 8: ...R TOUTES LES REGLES DE SECURITE ET INSTRUCTIONS D UTILISATION Hamilton Beach es una marca registrada de Halmilton Beach Brands Inc utilisé sous licence par Curtis International Ltd Pour obtenir assistance et information appelez 1 800 968 9853 Curtis International Ltd 7045 BECKETT DRIVE UNIT 15 MISSISSAUGA ON L5S 2A3 www curtisint com ...

Страница 9: ......

Страница 10: ...Le nom et la structure 1 Interupteurs 2 Bouteille d eau Inlet 3 Bouton d eau chaude 4 Bouton d eau froide 5 Voyants 6 Robinet d eau chaude 7 Robinet d eau froide 8 Bac de récupération ...

Страница 11: ...yer sur le bouton de chauffage et la lampe indicative rouge qui est devant s allume la machine commence à fonctionner Quand la température s élève à 86 95 C environ la lampe indicative rouge s éteint le chauffage s arrête et la machine passe au mode de conservation de la chaleur Quand la température de l eau est inférieure de 86 C le système de chauffage recommence automatiquement Appuyer sur le b...

Страница 12: ...evez la prise électrique et tournez le robinet de vidange pour enlever l eau dans le reservoir eau chaude resserrer alors le robinet ouvrir le robinet d eau froide pour vidanger l eau dans le réservoir eau froide S il n y a pas d eau qui s écoule du robinet de refroidissement arrêtez le commutateur de refroidissement jusqu à ce qu il y ait l eau sortant Attention Le dos du dispositif doit être élo...

Страница 13: ... que vous pouvez vous procurer est au service après vente Guide de dépannage Problème Cause possible Le distributeur de l eau ne fonctionne pas Non branché Fusible débranché ou le disjoncteur a sauté Le refroidisseur de l eau n est pas assez froid Contrôler si le passage froid à l arrière est allumé Le distributeur d eau n a pas le dégagement correct L eau chaude n est pas assez chaude Contrôler s...

Страница 14: ...tial ou au destinataire du cadeau Conservez le reçu de vente original car une preuve d achat est nécessaire pour faire une réclamation de garantie Cette garantie est annulée si le produit est utilisé pour un usage autre que domestique ou s il est soumis à une tension ou une forme d onde autre que celle indiquée sur l étiquette par exemple 120V 60Hz Nous excluons toute réclamation pour des dommages...

Отзывы: