background image

®

Instruments

ENGLISH

MANUAL • HANDBUCH • MANUEL

3.3 GHz Portable

Spectrum Analyzer

HM5033

Содержание HM5033

Страница 1: ...Instruments ENGLISH MANUAL HANDBUCH MANUEL 3 3 GHz Portable Spectrum Analyzer HM5033...

Страница 2: ...2 Subject to change without notice...

Страница 3: ...3 Subject to change without notice...

Страница 4: ...pecified because doing so may cause damage to the unit Guarantee of quality Guarantee period Guarantees that it will repair any failure free of charge if it occurs because of our responsibility within...

Страница 5: ...uring value reading exceeding the instruments specifications may result from such conditions in individual cases 4 RF immunity of Spectrum Analyser 4 1 Electromagnetic RF field Although the interior o...

Страница 6: ...6 Subject to change without notice...

Страница 7: ...N HOLD mode 19 16 4 AVERAGE mode 19 16 5 OVER WRITE mode 19 17 Marker Peak Search MKR 19 17 1 Moving the marker 19 17 2 Setting the peak search 19 PEAK SEARCH 17 3 Changing the unit of marker point 19...

Страница 8: ...pectrum of the maximum level in the 3 3 GHz band and in addition optimum reference level resolution bandwidth video bandwidth and sweep time are set when the AUTO TUNE key is pressed This function is...

Страница 9: ...field probe measurement Frequency counter Frequency span Setting range 0 Hz zero span 200 kHz to 2 GHz 1 2 5step 3 3 GHz full span Accuracy kHz within 3 20 x t 1 dot frequency span 200 kHz to 10 MHz 2...

Страница 10: ...anel 1 LCD screen This is a large liquid crystal display with 240 V 320 H dots It simultaneously displays traces 8 10 div various setting values measured values etc 2 Input connector SMA J connector 3...

Страница 11: ...up 19 Print key When pressing this key the image is printed with a printer optional as it is 20 RS 232C key Sets baud rate and transfers a current or saved trace 21 Display control key Sets contrast b...

Страница 12: ...EAS F6 F2 21 Adj Ch WIDTH MEAS F6 F2 F3 21 ANT MEAS F6 F5 F1 22 AVER CALC F4 19 B B L DSPL F2 26 BACK SPACE FREQ F5 F6 15 BAND CNTR MEAS F6 F1 F1 F2 21 BAND WIDTH MEAS F6 F1 F1 F3 21 BAUD RS232C F2 26...

Страница 13: ...O ALL SCALE SCALE Refer to 10 Display Scale for details Set the display scale 10 dB 2 dB VBW VBW Refer to 12 Video Bandwidth for details Set the VBW MANU AUTO ALL SWEEP SWEEP Refer to 13 Sweep Axis fo...

Страница 14: ...electric overdischarge state and becomes the cause of contracting the life of a battery Please take care Moreover under low temperature near 0 C since a battery performancefallsandvoltagebecomeslow ev...

Страница 15: ...y pressing a unit key MHz RS232C or GHz DSPL Any figures below the resolution 100 kHz will be discarded 4 Changing the setting F5 Deletes the entire value and allows you to input one from the beginnin...

Страница 16: ...E dB A m 180 X F dBm F probe calibration coefficient changes by frequency 9 4 Relation between the reference level and ATT AMP in dBm indication The programmable attenuator ATT and the input amplifie...

Страница 17: ...se to set the RBW 3kHz 10kHz 30kHz 100kHz 300kHz 1MHz 3MHz 11 2 AUTO mode 1 When F2 is pressed optimum RBW is set according to the settings of SPAN and SWEEP Since is displayed on the right end of RBW...

Страница 18: ...mple points When sweep time is 10ms or 30ms detection mode is set to SMPL SWEEP MANU AUTO ALL SWEEP to switch over to the function screen shown below F1 F2 F3 F4 F5 F6 Press PosPK SMPL NegPK 14 AUTO T...

Страница 19: ...earch function NEXT peak function is available The display when an ZONE marker is selected The marker moves to the highest paek position automatically at ZONE mode inside specified zone 17 2 Setting t...

Страница 20: ...W 100 kHz Offset 0 0 dB VBW 10 kHz Impedance 50 Display scale 10 dB div 19 Measuring Function MEAS Select the measuring function F1 Ch Power Channel power measurement F2 Adj Ch Pw Adjacent channel lea...

Страница 21: ...nt Use F1 MODE to select a mode TOTAL BAND or PEAK It is each shown on MEAS area of LCD as ACPTOT ACP BAND or ACP PK The measured value and setting parameter are displayed at the right lower corner on...

Страница 22: ...nd VSWR are specified at a center of frequency range Items M301 M302 M303 Type Sleeve Sleeve Sleeve Frequency range 0 8 to 1 0 GHz 1 25 to 1 65 GHz 1 7 to 2 20 GHz Antenna gain 1 dBi 1 dBi 1 dBi or hi...

Страница 23: ...he antenna In addition a trace is not displayed for frequencies outside those supported by the antenna Example case of M301 Center frequency 900 MHz Frequency span 200 MHz Antenna directivity referenc...

Страница 24: ...24 Subject to change without notice M302 1 5 GHz E plane Antenna gain vs Frequency M303 2 0 GHz E plane Antenna gain vs Frequency M304 2 4 GHz E plane Antenna gain vs Frequency Measuring Function...

Страница 25: ...on of the probe ID Magnetic field strength measurement cannot be used without entering the Probe ID attached to the optional magnetic field probe CP 2S Once you have entered it you don t need to enter...

Страница 26: ...g It remains in the HOLD state after the printing is finished It stops printing if you press the PRINT again during printing Since the printer operates with power supply from either the AC adapter or...

Страница 27: ...equency Refer to 1 CF 2 5140G SP Frequency span Refer to 2 SP 20M RF Reference level Refer to 3 RF 10 dBm ST Sweep time and detection mode Refer to 4 ST 30 ms SMP RB Resolution bandwidth Refer to 5 RB...

Страница 28: ...PAN ZERO 200K 500K 1M 2M 5M 10M 20M 50M 100M 500M 1G 2G FULL unit Hz 4 Set the reference level Command REF 60 to 10 1step unit dBm For units other than dBm use the conversion formulas in 9 3 Refferenc...

Страница 29: ...dth mesurement Command OBWDB 0 1 to 40 0 0 1 step unit dB 21 Set the antenna of electric field strength measurement Command EFANT M301 M302 M303 M304 M305 USER Command Antenna M301 Setting date for M3...

Страница 30: ...arch mode Command PEAK NORM ZONE Command Peak search mode NORM Normal peak search ZONE Zone peak search 38 Request the peak search Command PKSEARCH 01 02 03 04 05 06 07 08 09 10 11 Command Position to...

Страница 31: ...strength measurement used the antenna prepared by the visitor or on the case of magnetic field strength measurement used the magnetic field probe prepared by the visitor it is necessary to write the d...

Страница 32: ...e of electric field strength measurement please select MEAS E F ANT on the case of magnetic field strength measurement please select MEAS M F PROBE Please push F1 and display USER on the upper of F1 N...

Страница 33: ...ance testing or formal testing is needed please contact the dealership where you purchased the product or contact us 25 1 Frequency characteristics Adjust the output level of the spectrum analyzer cal...

Страница 34: ...ibration microwave power meter etc Setting of HM5033 Reference level Specifications Measurement value Judgement 10 dBm within 1 4 dB 1 dot 0 dBm within 1 4 dB 1 dot 10 dBm within 1 4 dB 1 dot 15 dBm w...

Страница 35: ...ter frequency of HM5033 Output power 15 dBm However calibrate the signal generatorin advance 25 4 The display accuracy of the frequency span Adjust the frequency of the calibration equipment so that t...

Страница 36: ...output starting from the reference and measure the amplitude value of HM5033 Setting of HM5033 Display scales Output of calibration unit Specifications Measurement value Judgement 10 dB div XdBm adju...

Страница 37: ...37 Subject to change without notice...

Страница 38: ...38 Subject to change without notice...

Страница 39: ...39 Subject to change without notice...

Страница 40: ...0 Fax 49 0 61 82 89 09 30 E mail sales hameg de Printed in Germany Oscilloscopes Multimeters Counters Frequency Synthesizers Generators R and LC Meters Spectrum Analyzers Power Supplies Curve Tracers...

Отзывы: