10
L-703SP Surface Plate Calibration System
-
Hardware Overview
A-703SP-LM Surface-Plate Mounting Fixture
To accurately measure the flatness of surface plates, the L-703SP
requires a stable mounting fixture to hold the laser and a special flatness-
measuring base for the target to achieve the highest accuracy possible.
The A-703SP-LM is used to mount the L-703S (
) on flat
surfaces for measuring:
•
Flatness measurements of surfaces, such as surface plates.
•
Flatness, straightness & squareness measurements of machine tool
axes.
To secure the laser in the A-703SP-LM, insert the mounting stud into the
.4995 in. (12.7 mm) mounting hole in the fixture. Then use the thumb
screw to tighten the mounting stud. Make sure to make it very tight to
ensure a rigid mount and avoid laser drift issues.
Figure 12 - A-703SP-LM Laser Mounting Fixture Dimensions
Figure 11 - A-703SP-LM Surface-Plate Mounting Fixture