background image

5

Warning - renovation work, work in
the vicinity of the smoke detector

• Reinstall all correctly functioning smoke

detectors in their installation locations and
immediately replace any smoke detectors
that are no longer functioning correctly with
new devices.

• After installation, check all smoke detectors

for their function as described in

7.1. Testing

.

4.3 Installation locations and optimal
placement of smoke detectors

Note

The installation locations and positions of the
smoke detectors shown are only examples based
on average apartments and houses and are only
intended as a guide.

4.3.1 Not permitted installation locations

• Do not install smoke detectors in garages - the

combustion residues/exhaust gases produced
when starting a motor vehicle can trigger false
alarms.

• Unsuitable rooms are those in which temperatures

fall below 0°C or rise above 40° C or in which the
humidity is more than

93%.

• Do not attach the smoke detector e.g. to the

ceiling of a caravan or similar rooms. The sun's
rays heat the air quickly here, so that possible
smoke is thereby prevented from reaching the
smoke detector and triggering the alarm.

4.3.2 Installation locations with restrictions

• Also take into account the information in

4.2. Reasons for false alarms

.

• Smoke detectors must only be installed in kitchens

and wet rooms (bathrooms) if the restrictions
are observed and at the same time false alarms
caused by kitchen and water vapour can be
excluded.

• When installing the smoke detector near

dishwashers, washing machines, ovens, etc., keep
it at least 3 m away from these areas.

• When installing the smoke detector near ventila-

tion shafts or openings for heat and cold supply,
keep it at least 1 m away from these areas. The
air could blow the smoke away from the smoke
detector and thus interrupt or prevent the alarm.
Make sure that the air movement in such rooms
does not affect the penetration of

fi

re smoke into

the smoke detector.

• Perforated ceilings used for ventilation in forcibly

ventilated rooms must be closed within a radius
of 0.5 m around the smoke detector.

• In very dirty, dusty, greasy or insect-infested

areas, smoke detectors can become excessively
contaminated with dust and dirt, resulting in false
alarms or impaired smoke detection.

4.3.3 Standard rooms

• Smoke and combustion residues rise upwards

to the ceiling and then spread horizontally. The
ideal installation location is on the ceiling, in the
middle of the room.

• When installing, make sure that the smoke

detector is at least 0.5 m away from any side
wall and larger furnishings, e.g. high cupboards
(see Fig. 2a).

• A smoke detector is only permitted for room sizes

up to max

.

60 m

2.

If the room size exceeds 60 m

2

,

use additional smoke detectors. For example, at
least two smoke detectors should be installed in
rooms between 60 m² and 120 m² in size.

• A smoke detector is only approved for installation

heights up to max. 6 m. If the room height
exceeds 6 m, additional smoke detectors must be
installed at several levels.

max.

6 m

min. 0.5 m

min. 0.5 m

min. 0.5 m

2 a

Содержание GS536

Страница 1: ...Smoke Alarm GS536 Rauchwarnmelder 00 223841 D GB Operating Instructions Bedienungsanleitung...

Страница 2: ...mage the smoke detector must be replaced Draw up an escape plan in case of emergency see 6 1 for instructions The escape plan recommendation Warning of hearing damage The smoke detector alarm is very...

Страница 3: ...teries from the product and dispose of them without delay Avoid storing charging and using in extreme temperatures and at extremely low atmospheric pressures such as at high altitudes 4 Installation N...

Страница 4: ...ave a tendency to trigger false alarms due to their typical use This includes disruptive factors such as Water cooking and other vapours Welding soldering cutting and other hot work Sawing and grindin...

Страница 5: ...hen and water vapour can be excluded When installing the smoke detector near dishwashers washing machines ovens etc keep it at least 3 m away from these areas When installing the smoke detector near v...

Страница 6: ...itchens that serve as escape routes Corridors and rooms with a width 1 m the ideal installation location is on the ceiling centrally between the walls Corridors with a width 3 m in corridors with a ma...

Страница 7: ...rooms For pitched roofs with a roof pitch 20 the smoke detector must be installed at a distance of at least 0 5 m and max 1 m from the gable peak see Fig 5a 0 5 m 0 5 m 20 5 a Note the following for...

Страница 8: ...the individual ceiling panels is less than 36 m each the joists beams are not relevant and are to be seen as part of the ceiling The smoke detector can be installed on a ceiling panel or directly on t...

Страница 9: ...pprox every 32 seconds Battery compartment Battery 8 5 2 Installing the smoke detector Attach the smoke detector to the base plate affixed to the installation location by inserting the latching hooks...

Страница 10: ...rs and windows of your escape route if this can be done safely to slow down the spread of smoke and fire After leaving the house go to your agreed assembly point and make sure that everyone has left t...

Страница 11: ...cially the sensor is also limited in time Therefore before installing the smoke detector observe the date printed on it for replacement Replace the smoke detector with a new unit on this recommended d...

Страница 12: ...com 00223841 Downloads 10 Manufacturer and approval holder Siterwell Electronics CO Limited No 666 Qingfeng Road Jiangbei District Ningbo Zhejiang Province China Distributed by Hama GmbH Co KG 86652...

Страница 13: ...nshinweise Bei jeglicher Art von Besch digung ist der Rauchwarnmelder auszutauschen Erstellen Sie f r den Notfall einen Fluchtplan Hin weise dazu finden Sie unter 6 1 Der Fluchtplan Empfehlung Warnung...

Страница 14: ...iftige und umweltsch dliche Schwermetalle enthalten Entfernen und entsorgen Sie verbrauchte Batterien unverz glich aus dem Produkt Vermeiden Sie Lagerung Laden und Benutzung bei extremen Temperaturen...

Страница 15: ...und Umgebungen neigen aufgrund ihrer typischen Nutzung m glicherweise beg nstigt zur Ausl sung von Fehlalarmen Darunter fallen St rfaktoren wie z B Wasser Koch und sonstige D mpfe Schwei L t Trenn un...

Страница 16: ...itig Fehlalarme durch K chen und Wasserdampf ausgeschlossen werden k nnen Halten Sie bei der Installation des Rauchwarn melders in der N he von Geschirrsp lern Waschmaschinen fen etc mindestens 3 m Ab...

Страница 17: ...4 3 8 Wandmontage beschrieben zu bevorzugen Flure und R ume mit einer Breite 1 m Der ideale Montageort ist an der Decke mittig zwischen den W nden Flure mit einer Breite 3 m In Fluren mit einer maxima...

Страница 18: ...3 5 Standard R ume Bei Spitzd chern mit einer Dachneigung 20 ist der Rauchwarnmelder in einer Entfernung von mind 0 5 m und max 1 m von der Giebelspitze anzubringen siehe Bild 5a 0 5 m 0 5 m 20 5a Bea...

Страница 19: ...der jeweils kleiner als 36 m sind die Unterz ge Balken nicht relevant und als Bestandteil der Decke zu sehen Der Rauchwarn melder kann auf einem Deckenfeld oder direkt auf dem Unterzug Balken installi...

Страница 20: ...des Rauchwarnmelders Befestigen Sie den Rauchwarnmelder auf der an der Montagestelle angebrachten Grundplatte indem Sie die Rasthaken in die vorgesehenen ffnungen einf hren und den Rauchwarnmelder im...

Страница 21: ...bewohner Verlassen Sie nun sofort das Haus und schlie en Sie alle T ren und Fenster Ihrer Fluchtroute wenn dies gefahrlos m glich ist um die Aus breitung von Rauch und Brand zu verlangsamen Gehen Sie...

Страница 22: ...und Funktions berpr fung wie in 5 2 Montage des Rauchwarnmelders beschrieben durch Hinweis Neben der Lebensdauer der Batterie ist auch die Lebensdauer des Rauchwarnmelders insbesondere des Sensors zei...

Страница 23: ...Produkt finden Sie unter www hama com 00223841 Downloads 10 Hersteller und Genehmigungsinhaber Siterwell Electronics CO Limited No 666 Qingfeng Road Jiangbei District Ningbo Zhejiang Province China Di...

Страница 24: ...corresponding companies Errors and omissions excepted and subject to technical changes Our general terms of delivery and payment are applied Hama GmbH Co KG 86652 Monheim Germany Service Support www h...

Отзывы: