Hama 00186425 Скачать руководство пользователя страница 8

6

8. Recalibration of the product

Press and hold ANEW

(6)

for approximately 3 seconds to recalibrate the product.

Calibration should be carried out outdoors, as CO2 levels here are usually around

400-450ppm.

Please ensure that there is no CO2 source in the immediate vicinity. Avoid direct

sunlight and rain.

9. Care and maintenance

Note

Disconnect the device from the mains before cleaning and during prolonged periods

of non-use.

Only clean this product with a slightly damp, lint-free cloth and do not use

aggressive cleaning agents.

Ensure that no water is able to enter the product.

10.Warranty Disclaimer

The measuring device must not be used as a warning device for dangerously high

concentrations (e.g. industrial safety monitoring). It is not suitable for medical

institutions, certification or test measurements. The measuring device is primarily used

for testing purposes and for orientation in private households. No liability is accepted

for possible damage in case of malfunction.

It is not possible to transfer data via the USB cable.

Hama GmbH & Co KG assumes no liability and provides no warranty for damage

resulting from improper installation/mounting, improper use of the product or from

failure to observe the operating instructions and/or safety notes.

11. Technical data

Display mode

LED digital display

Device dimensions

125 x 80 x 35 cm

Measurement error

3 - 30%

Pre-warming time after switch on

120 seconds

Operating voltage

5V min. 1A

Battery capacity

1000 mAh

Charging time

Approx. 4 hours

Standby Time

Approx. 180-240 minutes

Содержание 00186425

Страница 1: ...GB Operating Instructions Bedienungsanleitung Air Quality Detector Luft Qualitäts Messgerät 00 186425 Air quality detector TVOC 0 0 0002 0684 0 030 02 mg m3 mg m3 ppm ppm AQI CO CO2 HCHO ON OFF RESET ANEW ...

Страница 2: ......

Страница 3: ...2 Air quality detector TVOC 0 0 0002 0684 0 030 02 mg m3 mg m3 ppm ppm AQI CO CO2 HCHO ON OFF RESET ANEW 1 2 3 10 4 5 6 7 11 8 9 ...

Страница 4: ...million 1 millionth 1 ppm 10 6 corresponds to 0 001 The Federal Environment Agency recommends letting fresh air into the room from outside if a value of 1 000 ppm CO is exceeded 9 CO Carbon monoxide concentration in ppm In unventilated rooms with gas burners fireplaces or cigarette smoke higher values are quickly reached If the CO concentration rises to values between 136 and 280 ppm fatigue dizzi...

Страница 5: ...gatively affect the product s functionality Do not drop the product and do not expose it to any major shocks Do not modify the product in any way Doing so voids the warranty Keep the packaging material out of the reach of children due to the risk of suffocation Dispose of packaging material immediately in accordance with the locally applicable regulations Route all cables so that there is no risk ...

Страница 6: ... by means of the red yellow green colour code When the battery is fully charged green the charging process can be terminated Disconnect the product from the mains In the case of battery operation the display goes out after approx 30 minutes Press ON OFF 4 briefly to make the display appear again Note charging process A complete charging cycle takes about 4 hours The product s battery can be charge...

Страница 7: ...can be drawn about aerosols with viruses e g Covid 19 present in the air Although these are not directly detectable increased CO2 pollution is at the same time a measure of virus contaminated air This can be remedied by regular airing Permanently inhaling bad and stale air can cause tiredness headaches eye irritation etc The ability to perform and concentrate decreases noticeably as a result The d...

Страница 8: ...dangerously high concentrations e g industrial safety monitoring It is not suitable for medical institutions certification or test measurements The measuring device is primarily used for testing purposes and for orientation in private households No liability is accepted for possible damage in case of malfunction It is not possible to transfer data via the USB cable Hama GmbH Co KG assumes no liabi...

Страница 9: ...cal and electronic devices as well as batteries to the designated public collection points or to the point of sale at the end of their service lives Detailed information on this topic is defined in the national laws of the respective country This presence of the above symbol on the product operating instructions or package indicates that the product is subject to these regulations By recycling reu...

Страница 10: ...el 1 ppm 10 6 entspricht 0 001 Das Umweltbundesamt empfiehlt bei der Überschreitung eines Wertes von 1 000 ppm CO frische Luft von draußen in den Raum zu lassen 9 CO Kohlenmonoxid Konzentration in ppm In unbelüfteten Zimmern mit Gasbrennern Kaminen oder durch Zigarettenrauch werden schnell höhere Werte erreicht Steigt die CO Konzentration auf Werte zwischen 136 und 280 ppm treten schon nach zwei b...

Страница 11: ...ion des Produktes negativ Lassen Sie das Produkt nicht fallen und setzen Sie es keinen heftigen Erschütterungen aus Nehmen Sie keine Veränderungen am Produkt vor Dadurch verlieren Sie jegliche Gewährleistungsansprüche Halten Sie Kinder unbedingt von dem Verpackungsmaterial fern es besteht Erstickungsgefahr Entsorgen Sie das Verpackungsmaterial sofort gemäß den örtlich gültigen Entsorgungsvorschrif...

Страница 12: ...zeige 1 zeigt durch den Farbcode rot gelb grün den Ladezustand an Bei Vollladung grün kann der Ladevorgang beendet werden Trennen Sie das Produkt vom Netz Bei Batteriebetrieb erlischt die Anzeige nach ca 30 Minuten Durch kurzes Drücken von ON OFF 4 erscheint die Anzeige wieder Hinweis Ladevorgang Ein kompletter Ladevorgang dauert ca 4 Stunden Der Akku des Produktes kann sowohl in ein als auch ausg...

Страница 13: ...t befindliche Aerosole mit Viren z B Covid 19 schließen Diese sind zwar nicht direkt nachweisbar eine erhöhte CO2 Belastung ist jedoch gleichzeitig ein Maß für virenbelastete Luft Abhilfe kann hier regelmäßiges Stoßlüften schaffen Dauerhaft schlechte und verbrauchte Luft einzuatmen kann u a zu Müdigkeit Kopfschmerzen Augenreizungen usw führen Die Leistungs und Konzentrationsfähigkeit lässt dadurch...

Страница 14: ...gefährlich hohe Konzentrationen z B Arbeitsschutzüberwachungen verwendet werden Es ist nicht geeignet für medizinische Einrichtungen Zertifizierungen oder Testmessungen Vornämlich dient das Messgerät zu Prüfzwecken und als Orientierung im privaten Hausgebrauch Es wird keinerlei Haftung bei Fehlfunktion für mögliche Schäden übernommen Es ist keine Datenübertragung über das USB Kabel möglich Die Ham...

Страница 15: ...ichtet elektrische und elektronische Geräte sowie Batterien am Ende ihrer Lebensdauer an den dafür eingerichteten öffentlichen Sammelstellen oder an die Verkaufsstelle zurückzugeben Einzelheiten dazu regelt das jeweilige Landesrecht Das Symbol auf dem Produkt der Gebrauchsanleitung oder der Verpackung weist auf diese Bestimmungen hin Mit der Wiederverwertung der stofflichen Verwertung oder anderen...

Страница 16: ...ll listed brands are trademarks of the corresponding companies Errors and omissions excepted and subject to technical changes Our general terms of delivery and payment are applied Service Support www hama com 49 9091 502 0 DG 00186425 10 20 ...

Отзывы: