You can now rename your thermostats if you wish to
by pressing on the pen symbol next to the device name.
•
Press "Done" to end the integration process.
•
Slide the "Activate" button at the bottom edge of the screen from right to left to enable the radiator
thermostat control.
•
You can now set and configure your radiator thermostat using the app.
5. Configuring thermostats
•
For simple temperature setting, there are four different operating modes available under "Program" for each
day of the week.
•
This gives you the option of pre-setting the temperature of your radiator automatically at various times of the
day. The programs pre-set in the app mean you can also carry out further automatic temperature changes.
Under "Settings", you can activate the limescale protection, anti-frost protection, window open detection, child
safety and temperature calibration functions.
These functions, along with a few other setting options, are explained below.
Limescale protection
•
If the radiator valve is not opened for two or more weeks, this can cause limescale to build up in the valve.
•
To prevent this, the radiator thermostat opens the valve for 30 seconds every two weeks. The display shows
"AS" during this process.
Anti-frost protection
•
In Off mode, the display shows
.
•
If the temperature falls below 5°C, the thermostat automatically activates the heating.
•
Heating continues until the temperature reaches 8°C. The thermostat then switches back to Off mode.
Window open detection
•
If a window is opened while the heating is on, the radiator thermostat automatically stops the heating process
if the temperature falls rapidly.
•
"OP" appears in the display. As soon as the window is closed and the temperature has risen again by 2°C, the
radiator thermostat automatically returns to normal operation.
4