Default settings:
• Measure distance every 5 minutes
• Report a distance measurement value every 1 minute
• Report battery-level every 6 hours
• Distance sensor measurement mode is short-range
• The sensor is in routing-mode
The following parameters are configurable remotely over Thingsee
Operations Cloud:
• Measurement interval
• Reporting interval
• Reporting event threshold
• Region of Interest (ROI) from 16x16 matrix, min 4x4 enabling
• Angle of measurement
• Direction of interest
• Mesh network node role; Routing / Non-routing
• Timing budget to balance between power consumption and
measurement noise
Change of distance measurement modes:
• 1: Short range mode 40 mm - 1300 mm
• 2: Long range mode up to 4000 mm
Default measurement and reporting
Settings’ impact on battery-life
• 1 min measurement interval up to 2,5 years (default setting)
• 5 min measurement interval up to 3,5 years
• 15 min measurement interval up to 4 years