NEXUS R3 WIRING

Injector Outputs

All injectors are to be wired directly to the VCU’s 
corresponding cylinder output pins. 
When an injection event occurs the VCU will 
ground the output pin, opening the injector.
All injectors must be wired to a 12V 
supply from one of the High Current Outputs on 
the NEXUS R3.
When not used for injection, pins can be used as 
generic Digital Pulsed Outputs (DPO) capable of 
switching 2A to ground.

Specs:

• Number of channels: 8
• Current controlled output
• 8A Peak, 2A Hold
• 0 to 55V voltage feedback

Unused injector outputs can also be used as:
• Generic switched or PWM outputs (2A)
• Low speed digital switch inputs (0-12V)

INJ 1

INJ 4

INJ 2

INJ 3

INJ 5

INJ 8

INJ 6

INJ 7

25A-

HCO1

8-CYL

INJECTION

SEQUENTIAL

1

3

5

7

2

4

6

8

(WIRE AS PER CYLINDER ORDER)

16

Example wiring connection shown: Sequential injection wiring with 25A-HCO1 used as injector 12V. 
Ensure the high current output used to power the injectors is capable of supplying the required 
current.

Ignition Outputs

The ignition outputs produce a signal between 
12V and ground to control the charging and firing 
of an ignition coil. Ignition outputs can only be 
connected directly to ignition coils if the coils are 
equipped with internal ignitors. 
Ignition coils without internal ignitors draw large 
amounts of current and thus must use an external 
ignitor module to be safely triggered by the 
VCU. Connecting directly to ignition coils without 
internal ignitors will damage the VCU.  

Specs:

• Number of channels: 8
• Software selectable global 12V or  5V pull-up
• Software selectable individual 270R pull-up
• 10kHz switching speed
• Automatic overtemp, overcurrent, flyback 
  protection
• 0 to 27V voltage feedback
Unused ignition outputs can also be used as:
• Generic DPO (3A sink) or PWM outputs
• Low speed digital switch inputs (0-12V)

WARNING

Connecting the VCU to an ignition module before 
setting the ignition firing edge correctly may 
damage the module and coils, therefore it is 
advised to disconnect the module or disable the 
power to the ignition system until the unit has 
been setup and configured.

IGN 1

IGN 4

IGN 2

IGN 3

IGN 5

IGN 8

IGN 6

IGN 7

25A-

HCO2

8-CYL DIRECT FIRE IGNITION

1

3

5

7

2

4

6

8

(WIRE AS PER CYLINDER ORDER)

Example wiring connection shown: Direct fire ignition wiring with 25A-HCO2 used as ignition coil 12V. 
Ensure the high current output used to power the ignition coils is capable of supplying the required 
current.
NOTE: The coils depicted in this diagram (HT-020102) have internal ignitors. Do not connect ignition 
outputs directly to coils unless they have internal ignitors as this will damage the VCU. If your coils 
are without internal ignitors an external ignitor must be used.

Содержание NEXUS R3

Страница 1: ...1 QUICK START GUIDE ...

Страница 2: ...tions linking two or more things a connected group or series the central or most important point or place Optional accessories sold separately Plug and pins set AMP 34 pin key 1 AMP 34 pin key 2 DTP 4 pin HT 030013 NEXUS R3 Universal Wiring Harness 2 5m HT 183200 Glass mount Wi Fi antenna with 1 5m terminated lead HT 011401 Wideband Flying Lead Adaptor Harness 400mm HT 010723 LSU4 9 Wideband Hardw...

Страница 3: ...in power or low power mode Blue Connect to unit and install firmware Red Hardware fault DTC None DTCs not present Yellow A DTC is present of any kind past present not severe severe WiFi None Wi Fi is disabled Green solid Wi Fi is enabled Green flashing Wi Fi is enabled and connected to NSP Datalog None Unit is not logging Yellow flashing Unit is logging unit is not looping or not full Yellow Unit ...

Страница 4: ...s per log 300 DIMENSIONS Enclosure Not including connector protrusion 196 x 130 x 44 5 mm 7 7 x 5 2 x 1 8 in Overall Including connector protrusion 196 x 149 x 44 5 mm 7 7 x 5 9 x 1 8 in Weight 1 15 kg 2 53 lbs Operating Temperature ambient 40 to 85 C 40 to 185 F 12 x Onboard Temperature Sensing Zones ECU 40 to 125 C 40 to 255 F PDM 40 to 150 C 40 to 302 F ELECTRICAL Power Supply across power term...

Страница 5: ...s are disabled in low power mode Setting up Wi Fi communications Wi Fi communications can be enabled using NSP in the Wi Fi Module Settings When disabled the module is held in an OFF state and is completely inactive To set up your Wi Fi connection follow these steps 1 Open NSP and connect to your NEXUS R3 via the supplied USB C cable 2 Click on Connections in the feature tree and enable the Wi Fi ...

Страница 6: ...d to battery negative or the chassis CHASSIS ENGINE BATTERY GROUND PIN A10 A11 Ignition Switch The ignition switch input pin A13 must be connected to a switched 12V source to turn the NEXUS R3 on Method 1 If wiring to an existing ignition key switch in the vehicle it is important to make sure to wire A13 to the main ignition wire i e not accessory so it doesn t loose power while the engine is cran...

Страница 7: ...12 13 196mm 130mm 6 50mm 61 9mm 174 2mm MOUNTING TEMPLATE MOUNTING TEMPLATE ...

Страница 8: ... cable is used for crank and cam position sensors Shields must be terminated to battery ground at one end only Specs 10V to 10V input Selectable 1k2 or 440R pull up to 5V Selectable ground reference full differential standard mode 75 to 75V indefinite withstand 48kHz max signal frequency There are two common types of crank cam sensor signals Hall effect optical signal 0 5V digital square wave sign...

Страница 9: ...ion coils without internal ignitors draw large amounts of current and thus must use an external ignitor module to be safely triggered by the VCU Connecting directly to ignition coils without internal ignitors will damage the VCU Specs Number of channels 8 Software selectable global 12V or 5V pull up Software selectable individual 270R pull up 10kHz switching speed Automatic overtemp overcurrent fl...

Страница 10: ...e output You can use the NSP software to define the maximum number of retries before the output is deactivated until the next VCU reboot The VCU LEDs conveniently display the output state 25A HCOs are PWM capable and can be used for ignition power and injector power as well as to PWM thermofans and fuel pumps control HBO 1 HBO 4 HBO 2 HBO 3 DBW THROTTLE 2 DBW THROTTLE 1 The NEXUS R3 supports up to...

Страница 11: ...l frequency band 3V indefinite AC voltage withstand 50V indefinite DC withstand Example Wiring Connections Example Wiring Connections Analog Voltage Inputs AVI Analog Voltage Inputs are inputs to the VCU that accept variable voltage signals from 0V to 5V such as signals from pressure temperature and position sensors These inputs can also accept switched inputs that change between two different vol...

Страница 12: ...t overcharge the battery or reverse the polarity of the battery or any charging unit Discon nect the Haltech ECU from the electrical system whenever doing any welding on the vehicle by unplugging the wiring harness connector from the ECU After completing the ECU installation make sure there is no wiring left un insulated Uninsulated wiring can cause sparks short circuits and in some cases fire Bef...

Страница 13: ... 0616 Email nz haltech com Haltech USA East 750 Miles Point Way Lexington KY USA 40510 Phone 888 298 8116 Email usa haltech com Haltech USA West Race Winning Brands 10800 Valley View Street Cypress CA 90630 Phone 888 298 8116 Email usa haltech com Haltech UK Unit 1 Miras Business Estate Keys Park Road Hednesford WS12 2FS Phone 44 121 285 6650 Email uk haltech com Haltech Europe Ottogasse 2A 2333 L...

Отзывы: