background image

12

13

8A High Current Outputs (8A HCO)

The Nexus PD16 features 10 high side outputs 
capable of driving 8A to 12V. Each output has a 
software programmable fuse current. 

Once the electronic fuse blows the output turns 
off for a software programmable delay duration, 
before reactivating the output.

Use the NSP software to define the maximum 
number of retries before the output is deactivated 
until the next power cycle. The PD16 LEDs display 
the output state.

8A HCOs are PWM capable and can be used 
to power CAN devices or solenoids as well as 
transmission shift solenoids, water pumps, etc.

Specs:

• Automatic overcurrent protection 
• Flyback protected 
• 0 to 30V voltage feedback 
• High side current feedback 
• 100Hz max switching speed 
• Capable of 0-100% duty cycle

25A High Current Outputs

The four high/low outputs on the Nexus PD16 
are capable of sinking 25A to ground and driving 
25A to 12V. Each output has a programmable fuse 
current, slow-start current and duration.

Once the electronic fuse blows the output turns 
off for a pre-programmed delay duration before 
reactivating the output. The PD16 LEDs display the 
output state.

25A HCOs are PWM capable and can be used for 
ignition power and injector power as well as to 
PWM thermofans and fuel pumps etc.

Specs:

 

• Automatic overcurrent protection 
• Flyback protected 
• 0 to 30V voltage feedback 
• High side current feedback 
• 1kHz max switching speed 
• Capable of 0-100% duty cycle

ELECTRIC WATER PUMP

8A HCO

GROUND

25A HCO

TO GROUND

THERMOFAN

Example 25A HCO Wiring Connections

Example 8A HCO Wiring Connections

NEXUS PD16 WIRING

Analog Voltage Inputs (AVI)

Analog Voltage Inputs accept variable voltage 
signals from 0V to +5V such as signals from 
pressure, temperature and fuel level sensors.

These inputs can also accept switched inputs that 
change between two different voltage levels. 

The On Voltage and Off Voltage define what the 
thresholds are between the on and off states.

The voltage can be viewed as a channel in NSP to 
determine the thresholds for a switched input.

Common examples of switched inputs include A/C 
Request switch and intercooler spray switch.

AVIs have a software selectable 1K pull-up 
resistor to 5V, which can be enabled or disabled 
within the Setup page.

Pull-up resistors are generally enabled for 
temperature related sensors and switched to 
ground inputs.

Specs:

• 0 to 5V 
• 100 samples per second 
• Selectable 1k pull-up to 5V 
• -10 to 30V indefinite withstand 
• 1.5kHz signal frequency max 
• AVI-1 has a switchable 240Ω pull up

 

that allows 

  direct connection with fuel level sender input.

AVI

AVI

SIGNAL 

GROUND

SIGNAL 

GROUND

SENSOR

 +5V

TEMPERATURE

SENSOR

ROTARY TRIM MODULE

HT-010504

AVI

AVI

SIGNAL 

GROUND

SIGNAL 

GROUND

SENSOR

 +5V

TEMPERATURE

SENSOR

ROTARY TRIM MODULE

HT-010504

Pull-up resistors are generally enabled for 
temperature related sensors and switched 
to ground inputs. The following configuration 
requires the pull-up resistor be enabled.
NOTE: AVI-1 has 1k or 240Ω pull up options for 
fuel level sensors.

For in-depth product overviews, 

step-by-step set up guides, software 

walk-throughs and tech tips go to 

the Haltech YouTube channel.

SCAN ME

 

Sensors with a +5V supply do not require the pull-up 
resistor be enabled, for example, rotary trim modules.  
Any 5V pin can be used with any Signal Ground 
pin for sensors.

Содержание NEXUS PD16

Страница 1: ...1 QUICK START GUIDE...

Страница 2: ...ependable power delivery to your vehicle NEXUS PD16 OVERVIEW NEX US noun a connection or series of connections linking two or more things a connected group or series the central or most important poin...

Страница 3: ...itch Input 1 OTHER 5V Sensor Supply 1 Sensor Ground 1 COMMUNICATIONS CAN Bus Network 1000 kbit s 1 Full Speed USB Firmware upgrade only 1 ELECTRICAL Power Supply across power terminals 8 to 20V No out...

Страница 4: ...onnected to battery positive and battery negative at all times It s important to use correct gauge cables when connecting the Nexus PD16 to the battery terminals Connect the Nexus PD16 to the positive...

Страница 5: ...8 9 MOUNTING TEMPLATE MOUNTING TEMPLATE...

Страница 6: ...ts as a peripheral device to provide the ECU additional I O common on Nexus VCU applications The PD16 is switched on and off via CAN power connection Ensure PD16 has battery power and ground The ignit...

Страница 7: ...ctions NEXUS PD16 WIRING Analog Voltage Inputs AVI Analog Voltage Inputs accept variable voltage signals from 0V to 5V such as signals from pressure temperature and fuel level sensors These inputs can...

Страница 8: ...ical work on your vehicle Avoid sparks open flames or use of electrical devices near flammable substances Do not run the engine with a battery charger connected as this could damage the ECU and other...

Страница 9: ...ail usa haltech com Haltech USA West Race Winning Brands 10800 Valley View Street Cypress CA 90630 USA Phone 1 888 298 8116 Email usa haltech com Haltech Europe Ottogasse 2A 2333 Leopoldsdorf Austria...

Отзывы: