Instruction Manual PSx3xxSE
6
Never run the PSx3xxSE in reverse (i.e. do not apply external force to the
output shaft in order to turn it).
2.3
Pin assignment
For the supply voltage either a Binder series 713/763 (A-coded) round, 5-pin plug for PSE and
PSS devices or a 5-pin Harting plug with protective sleeve (HAN4A) for the PSE34xx devices
is located in the housing cover of the PSx3xxSE.
Two round 4-pin sockets, Binder series 825 (D-coded) are provided for connection to the bus.
2.3.1 Supply voltage connector
1. +24V motor
2. ground (motor)
3. +24V control unit
4. ground (control unit)
5. housing/pressure balance
To prevent the ingression of fluids into the PSW-housing during
cooldown, use a special cable with an airtube for pressure
balancing of your PSW.
2.3.2 Sockets for the bus
1. TD+ (WH/GN, white/green)
2. RD+ (WH/OG, white/orange)
3. TD- (GN, green)
4. RD- (OG, orange)
Due to the use of 4-pin sockets, only four-wire cables should be used.
2.3.3 Electrical grounding
Next to the connecting plugs there is a M4 stud bolt. It is recommended to connect the
positioning system with a cable as short as possible to the machine base. The minimum wire
cross section therefor is 1.5mm².
2.4
Setting the device address
In its delivery state, the PSx3xxSE has the address 1. A different address can be assigned
using the parameter S-0-1040 or via the optional address switches. If the switches are resting
in the position 00 or not available, the address is set using S-0-1040. The change in address is
saved automatically and therefore continues to be available after the device is restarted.
If you set the address using the switches (i.e. switches set to > 00) you cannot change this
value using the bus.
Содержание PS*3**SE series